Quantitative determination by UHPLC-MS/MS of 18 common drugs of abuse and metabolites, including THC and OH-THC, in volumetric dried blood spots: a sustainable method with minimally invasive sampling

被引:3
作者
Ververi, Christina [1 ,2 ]
Gentile, Claudia [1 ]
Massano, Marta [1 ,2 ]
Salomone, Alberto [1 ,2 ]
Vincenti, Marco [1 ,2 ]
机构
[1] Univ Turin, Dept Chem, Turin, Italy
[2] Ctr Reg Antidoping, Orbassano, Italy
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2024年 / 1247卷
关键词
Drugs of abuse; DBS; THC; HPLC-MS/MS; LC-MS/MS; MASS-SPECTROMETRY; STABILITY; ASSAYS;
D O I
10.1016/j.jchromb.2024.124337
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The increased use of drugs of abuse urges forensic toxicologists to create quick, simple, minimally invasive sampling techniques for biological fluids combined with analytical methods assuring accurate results. To this purpose, a method was developed aimed at quantifying 18 drugs of abuse and metabolites in DBS. Validation of the method was conducted by spiking blank whole blood with the analytes on Capitainer (R) B cards. The extracts were analyzed by a targeted UHPLC-MS/MS method. Linear calibration was achieved in the range of 1-100 ng/ mL for: amphetamine, MDA, MDMA, methamphetamine, cocaine, codeine, benzoylecgonine, cocaethylene, morphine, 6-MAM, buprenorphine, methadone, EDDP, ketamine, norbuprenorphine norketamine, THC, and OHTHC. Experimental LOD was found at 0.5 ng/mL for all analytes except for norbuprenorphine, THC and THC-OH which yielded a LOD of 1 ng/mL. Intra- and inter-day accuracy was satisfactory with bias% resulting within 5%. Evaluation of intra- and inter-day precision yielded CV% values within 20%, for all compounds except EDDP. Average extraction recovery calculated at low (2 ng/mL) and high (75 ng/mL) concentration levels was 63% while average matrix effect determined at the same levels was found to be within 85% - 115% for all analytes except from codeine (70%) and MDMA (131%). The method was applied to authentic blood samples spotted onto the DBS card and the minimum value detected was 1.3 ng/mL. HPLC-MS/MS proved capable to identify all the targeted analytes at low concentrations in the small blood volumes obtainable from DBS cards, which in turn confirmed to be effective and sustainable micro-sampling devices.
引用
收藏
页数:11
相关论文
共 39 条
[1]   Stability of benzodiazepines and cocaine in blood spots stored on filter paper [J].
Alfazil, Abdulkareem A. ;
Anderson, Robert A. .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2008, 32 (07) :511-515
[2]   Effective validation of chromatographic analytical methods: The illustrative case of androgenic steroids [J].
Alladio, E. ;
Amante, E. ;
Bozzolino, C. ;
Seganti, F. ;
Salomone, A. ;
Vincenti, M. ;
Desharnais, B. .
TALANTA, 2020, 215
[4]  
Bang I., 1913, Der Blutzucker, DOI [10.1007/BF01347215, DOI 10.1007/BF01347215]
[5]   Determination of Morphine and 6-Acetylmorphine in Blood With Use of Dried Blood Spots [J].
Boy, Regine Garcia ;
Henseler, Joerg ;
Mattern, Rainer ;
Skopp, Gisela .
THERAPEUTIC DRUG MONITORING, 2008, 30 (06) :733-739
[6]   Multicenter evaluation of use of dried blood and plasma spot specimens in quantitative assays for human immunodeficiency virus RNA: Measurement, precision, and RNA stability [J].
Brambilla, D ;
Jennings, C ;
Aldrovandi, G ;
Bremer, J ;
Comeau, AM ;
Cassol, SA ;
Dickover, R ;
Jackson, JB ;
Pitt, J ;
Sullivan, JL ;
Butcher, A ;
Grosso, L ;
Reichelderfer, P ;
Fiscus, SA .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (05) :1888-1893
[7]  
CapitainerB, CapitainerB, Product specifications
[8]   Application of tandem mass spectrometry to biochemical genetics and newborn screening [J].
Carpenter, KH ;
Wiley, V .
CLINICA CHIMICA ACTA, 2002, 322 (1-2) :1-10
[9]  
E. M. A. Committee for Medicinal Products for Human Use, 2022, ICH guideline M10 on bioanalytical method validation and study sample analysis
[10]  
European Monitoring Centre for Drugs and Drug Addiction, 2023, European Drug Report 2023: Trends and Developments