A Measurement Method of Winding Loss for High-Frequency Transformer Based on Auxiliary Winding

被引:0
|
作者
Wang T. [1 ]
Luo R. [1 ]
Wen J. [1 ]
Zhang M. [1 ]
Tian J. [1 ]
机构
[1] NR Electric Co, Ltd, Nanjing
关键词
Auxiliary winding; Error analysis; High-frequency transformer; Winding loss;
D O I
10.19595/j.cnki.1000-6753.tces.210528
中图分类号
学科分类号
摘要
The measurement of winding loss is a difficult issue in the modeling and design of high-power high-frequency transformers (HFT), and a high precision winding loss measurement method is an important tool for verifying the correctness of winding loss theory and improving the accuracy of modeling and simulation. The accuracy of short-circuit impedance measurement method widely used at present decreases with the increase of measurement frequency, so it is not suitable for HFT. Creating additional measurement nodes by aiding auxiliary windings (AW) is an effective measure to improve the measurement accuracy of winding loss. An equivalent circuit model including stray parameters of AW was established, and the analysis results show that the leakage inductance and coupling capacitance between AW and winding under test (WUT) greatly affect the frequency range and accuracy of winding loss measurement. A correction method of winding resistance measurement considering coupling capacitance was proposed, which extended the measurement range of frequency and kept the measurement accuracy under high frequency. A single strand in Litz wire winding was used as AW, the leakage between AW and WUT was thus reduced to a very low level, and the engineering practice of winding loss measurement was simplified. By measuring the winding parameters of a 100kVA HFT prototype, the circuit model and the correction method were verified, and the effective measurement of the winding AC resistance at 1MHz was realized. © 2022, Electrical Technology Press Co. Ltd. All right reserved.
引用
收藏
页码:2622 / 2630and2655
相关论文
共 19 条
  • [1] Tu Chunming, Huang Hong, Lan Zheng, Et al., Coordinated control strategy of power electronic transformer and energy storage in microgrid, Transactions of China Electrotechnical Society, 34, 12, pp. 2627-2636, (2019)
  • [2] Lan Zheng, Tu Chunming, Jiang Fei, The flexible interconnection strategy between DC microgrid and AC grid based on virtual electric machinery technology, Transactions of China Electrotechnical Society, 34, 8, pp. 1739-1749, (2019)
  • [3] Zhou Bingkai, Yang Xiaofeng, Zhang Zhi, Et al., Multi-objective optimization control strategy of dual-active-bridge DC-DC converter in electric energy router application, Transactions of China Electrotechnical Society, 35, 14, pp. 3030-3040, (2020)
  • [4] Li Zixin, Gao Fanqiang, Xu Fei, Et al., Power density analysis of 10kVAC-750VDC/1MVA power electronic transformer/solid-state transformer for medium voltage distribution grid, Advanced Technology of Electrical Engineering and Energy, 35, 6, pp. 1-6, (2016)
  • [5] Leibl M, Ortiz G, Kolar J W., Design and experimental analysis of a medium-frequency transformer for solid-state transformer applications, IEEE Journal of Emerging & Selected Topics in Power Electronics, 5, 1, pp. 110-123, (2017)
  • [6] Guillod T, Huber J, Krismer F, Et al., Litz wire losses: effects of twisting imperfections, 2017 IEEE 18th Workshop on Control and Modeling for Power Electronics (COMPEL), pp. 1-8, (2017)
  • [7] Marko, Mogorovic, Drazen, Et al., 100kW, 10kHz medium-frequency transformer design optimization and experimental verification, IEEE Transactions on Power Electronics, 34, 2, pp. 1696-1708, (2019)
  • [8] Zhang Ke, Cao Xiaopeng, Qiao Guangyao, Et al., Analysis of winding loss calculation methods for high frequency transformers, Proceedings of the CSEE, 39, 18, pp. 5536-5546, (2019)
  • [9] Ehrlich S, Rossmanith H, Sauer M, Et al., Fast numerical power loss calculation for high frequency litz wires, IEEE Transactions on Power Electronics, 36, 2, pp. 2018-2032, (2020)
  • [10] Chen Bin, Li Lin, Semi-empirical model for precise analysis of copper losses in high-frequency transformers, IEEE Access, 6, pp. 3655-3667, (2018)