Experimental Study on Shear Performance of Segmental Assembly Continuous Composite Box Girder with Variable Cross-section Corrugated Steel Webs

被引:0
|
作者
Zhao P. [1 ,2 ,3 ]
Shao X. [3 ]
Rong X. [1 ,2 ]
Liu X. [4 ]
机构
[1] Key Laboratory of Roads and Railway Engineering Safety Control, Shijiazhuang Tiedao University, Ministry of Education, Shijiazhuang
[2] School of Civil Engineering, Shijiazhuang Tiedao University, Shijiazhuang
[3] College of Civil Engineering, Hunan University, Changsha
[4] Hebei Free Trade Zone Hancao Railway Co. ,Ltd, Tangshan
来源
Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences | 2024年 / 51卷 / 03期
基金
中国国家自然科学基金;
关键词
bridge engineering; corrugated steel webs; laboratory test; segmental assembly; shear performance; shear resistance; variable cross-section;
D O I
10.16339/j.cnki.hdxbzkb.2024039
中图分类号
学科分类号
摘要
To study the shear performance of segmental prefabricated continuous composite box girder with corrugated steel webs,two scaled test beams were made,including segmental continuous box girder with variable section corrugated steel webs and monolithic continuous box girder with variable section corrugated steel webs in the same size. Through static tests and numerical analyses,the distribution of shear stress and shear ratio of corrugated steel webs are obtained. The results show that the shear stress of the corrugated steel webs of the segmental and monolithic beams at 1/4 of the mid-span is evenly distributed along the beam height,and the shear stress value of the segmental beams is greater than that of the monolithic beams. The calculation formula of shear stress of segmental assembly box girder with variable section corrugated steel webs is derived,and the effect of construction technology on shear stress is considered. The shear ratio of corrugated steel webs of two test beams is less affected by the load and maintains a constant ratio. The shear ratio of the steel web of the two test beams at the position of the middle support is about 50%,and increases along the longitudinal direction of the test beam to both sides. At the position of 1/4 of the middle span,the shear ratio of the steel web of the segment-assembled beam reaches more than 85%,and the shear ratio of the steel web of the whole beam is about 75%. The shear ratio of the two testing beams at the corresponding position of the side span is not much different. The shear strength calculation formula of the AASHTO joint applicable to segmental concrete box girder multiplied by 0.9 can be applied to the calculation of the shear bearing capacity of the joint section. The error between the above formula value and the experimental value as well as with the finite element result is about 5 % . It can better predict the shear strength of steel-concrete composite structure adhesive joints. © 2024 Hunan University. All rights reserved.
引用
收藏
页码:170 / 181
页数:11
相关论文
共 21 条
  • [1] NIE J G, LI F X., Theory model of corrugated steel web girder considering web shear behavior[J], China Journal of Highway and Transport, 24, 6, pp. 40-48, (2011)
  • [2] LI J, WU H P,, CHEN H., Analysis of steel web shear capacity of variable section continuous system composite box beam bridge with corrugated steel webs[J], Bridge Construction, 45, 1, pp. 79-84, (2015)
  • [3] SHEN Y, CAI P,, CHEN L S, Shear strength of keyed joints in segmental precast concrete bridges[J], Journal of Tongji University(Natural Science), 47, 10, pp. 1414-1420, (2019)
  • [4] SAYED-AHMED E Y., Behaviour of steel and(or)composite girders with corrugated steel webs[J], Canadian Journal of Civil Engineering, 28, 4, pp. 656-672, (2001)
  • [5] YI J, GIL H, YOUM K, Interactive shear buckling behavior of trapezoidally corrugated steel webs [J], Engineering Structures, 30, 6, pp. 1659-1666, (2008)
  • [6] MOON J, YI J, CHOI B H, Et al., Shear strength and design of trapezoidally corrugated steel webs[J], Journal of Constructional Steel Research, 65, 5, pp. 1198-1205, (2009)
  • [7] LIU Z, CHONG A X, Full-scale model test for precast and assembled segmental box girder of the fourth Nanjing Changjiang River bridge[J], Bridge Construction, 41, 3, pp. 9-12, (2011)
  • [8] YUAN A M,, HE Y, DAI H, Force bearing performance test of precast segmental bridge beams with different tendon ratios under different loads[J], Journal of Chang’an University (Natural Science Edition), 36, 1, pp. 58-68, (2016)
  • [9] YUAN A M, WU W X,, SUN D S, Experimental on flexural behavior of segmental precast concrete beam with internal tendons and external tendons[J], Journal of Chang’an University (Natural Science Edition), 35, 5, pp. 73-81, (2015)
  • [10] SHI X F, LIU Z Q,, HU K, Full-scale test of bearing capacity of a complete external prestressed segmental precast continuous girder bridge[J], China Journal of Highway and Transport, 31, 12, pp. 163-173, (2018)