Method development and optimization for dispersive liquid-liquid microextraction factors using the response surface methodology with desirability function for the ultra-high performance liquid chromatography quadrupole time of flight mass spectrometry determination of organic contaminants in water samples: risk and greenness assessment

被引:1
作者
Makwakwa, Tlou Auguston [1 ,2 ]
Moema, Elsie Dineo [1 ]
Msagati, Titus Alfred Makudali [2 ]
机构
[1] Univ South Africa, Coll Sci Engn & Technol, Dept Chem, ZA-1709 Johannesburg, Florida, South Africa
[2] Univ South Africa, Coll Sci Engn & Technol, Inst Nanotechnol & Water Sustainabil, ZA-1709 Johannesburg, Florida, South Africa
关键词
PERSONAL CARE PRODUCTS; EXPERIMENTAL-DESIGN; PHARMACEUTICALS; EXTRACTION; PESTICIDES;
D O I
10.1039/d4ay01462f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, cost effective, and efficient dispersive liquid-liquid microextraction method was developed and optimized for the determination of organic contaminants in different environmental water matrices followed by UHPLC-QTOF-MS analysis. In the preliminary experiments, the univariate optimization approach was used to select tetrachloroethylene and acetonitrile as extraction and disperser solvents, respectively. The significant factors influencing DLLME were screened using full factorial design, and the optimal values for each variable were then derived through further optimization using central composite design with desirability function. The optimal conditions were achieved with 195 mu L of tetrachloroethylene as the extraction solvent, 1439 mu L of acetonitrile as the disperser solvent, and a sample pH of 5.8. Under these conditions, the method provided detection limits ranging from 0.11-0.48 mu g L-1 and recoveries ranging from 23.32-145.43% across all samples. The enrichment factors obtained ranged from 11.66-72.72. The proposed method was then successfully applied in real water samples. Only benzophenone was detected in the concentration range of 0.79-0.88 mu g L-1 across all the water samples. The calculated risk quotient resulting from benzophenone exposure in water samples showed a low potential risk to human health and the aquatic ecosystem. The method was also evaluated for its environmental friendliness using various metrics tools such as Analytical Eco-Scale (AES), Green Analytical Procedure Index (GAPI), Analytical GREEnness (AGREE), Analytical Greenness for Sample Preparation (AGREEprep), and Sample Preparation Metric of Sustainability (SPMS). Only AES qualified the method as green while it was considered acceptable and sustainable when assessed using SPMS. A simple, cost effective, and efficient dispersive liquid-liquid microextraction method was developed and optimized for the determination of organic contaminants in different environmental water matrices followed by UHPLC-QTOF-MS analysis.
引用
收藏
页码:7598 / 7612
页数:15
相关论文
共 50 条
  • [31] Rapid determination of anilines in water samples by dispersive liquid-liquid microextraction based on solidification of floating organic drop prior to gas chromatography-mass spectrometry
    Diao, Chun-Peng
    Wei, Chao-Hai
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (03) : 877 - 884
  • [32] Trace determination of organophosphate esters in white wine, red wine, and beer samples using dispersive liquid-liquid microextraction combined with ultra-high-performance liquid chromatography-tandem mass spectrometry
    Pang, Long
    Yang, Huiqiang
    Yang, Peijie
    Zhang, Hongzhong
    Zhao, Jihong
    FOOD CHEMISTRY, 2017, 229 : 445 - 451
  • [33] Application of liquid-liquid microextraction for the effective separation and simultaneous determination of 11 pharmaceuticals in wastewater samples using high-performance liquid chromatography with tandem mass spectrometry
    Diuzheva, Alina
    Balogh, Jozsef
    Jeko, Jozsef
    Cziaky, Zoltan
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (14) : 2870 - 2877
  • [34] A novel analytical approach for the determination of parathion methyl in water: quadrupole isotope dilution mass spectrometry-dispersive liquid-liquid microextraction using multivariate optimization
    Chormey, Dotse Selali
    Er, Elif Ozturk
    Erarpat, Sezin
    Ozzeybek, Gozde
    Ari, Betul
    Bakirdere, Sezgin
    ANALYST, 2018, 143 (05) : 1141 - 1146
  • [35] Response surface methodology for optimization and determination of Riluzole by microfunnel magnetic stirring-assisted liquid-liquid microextraction coupled with high-performance liquid chromatography
    Tohidi, Mitra
    Ramezani, Majid
    Mehramizi, Ali
    SEPARATION SCIENCE AND TECHNOLOGY, 2018, 53 (18) : 2926 - 2934
  • [36] Determination of sixteen pyrethroids in water using dispersive liquid-liquid microextraction based on dissolved carbon dioxide flotation after emulsification microextraction using gas chromatography with triple quadrupole mass spectrometry
    Ye, Jingqing
    Yao, Zhoulin
    Wang, Zhiwei
    Nie, Jing
    Li, Zuguang
    ANALYTICAL METHODS, 2016, 8 (32) : 6194 - 6201
  • [37] Simultaneous Determination of Sulfonamides Antibiotics in Environmental Water and Seafood Samples Using Ultrasonic-Assisted Dispersive Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography
    Wang, Yixiao
    Li, Jinhua
    Ji, Ling
    Chen, Lingxin
    MOLECULES, 2022, 27 (07):
  • [38] Trace determination of malachite green in water samples using dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-diode array detection
    Maleki, Ramin
    Farhadi, Khalil
    Nikkhahi, Yousef
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (09) : 1026 - 1035
  • [39] A New Dispersive Liquid-Liquid Microextraction Method Followed by Direct GFAAS Determination Optimized with Experimental Design and Response Surface Methodology for Determination of Ag(I) in Water Samples
    Ghiasvand, A. R.
    Shadabi, S.
    Hajipour, S.
    Nasirian, A.
    Sharghi, H.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2015, 2 (01): : 60 - 71
  • [40] Effective indirect enrichment and determination of nitrite ion in water and biological samples using ionic liquid-dispersive liquid-liquid microextraction combined with high-performance liquid chromatography
    He, Lijun
    Zhang, Kaige
    Wang, Caijuan
    Luo, Xianli
    Zhang, Shusheng
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (23) : 3595 - 3600