Real-time measurement of two-dimensional LET distributions of proton beams using scintillators

被引:0
|
作者
Isomura, Taiki [1 ,2 ,3 ]
Kamizawa, Satoshi [4 ]
Takada, Kenta [5 ]
Mori, Yutaro [4 ,6 ]
Sakae, Takeji [4 ,6 ]
机构
[1] Univ Tsukuba, Grad Sch Comprehens Human Sci, 1 1 1,Tennodai, Tsukuba, Ibaraki 3058577, Japan
[2] Medipolis Proton Therapy & Res Ctr, 4423 Higashikata, Ibusuki, Kagoshima 8910403, Japan
[3] Shin Nippon Biomed Labs, 2438 Miyanoura, Kagoshima, Kagoshima 8911394, Japan
[4] Univ Tsukuba Hosp, Proton Med Res Ctr, 2 1 1,Amakubo, Tsukuba, Ibaraki 3058576, Japan
[5] Gunma Prefectural Coll Hlth Sci, 323 1 Kamiokimachi, Maebashi, Gunma 3710052, Japan
[6] Univ Tsukuba, Inst Med, 1 1 1,Tennodai, Tsukuba, Ibaraki 3058575, Japan
关键词
LET; scintillator; LET measurement; LET distribution; proton therapy; PLASTIC SCINTILLATOR; QUALITY-ASSURANCE; DOSIMETRY;
D O I
10.1088/1361-6560/ad8546
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The linear energy transfer (LET) of proton therapy beams increases rapidly from the Bragg peak to the end of the beam. Although the LET can be determined using analytical or computational methods, a technique for efficiently measuring its spatial distribution has not yet been established. Thus, the purpose of this study is to develop a technique to measure the two-dimensional LET distribution in proton therapy in real time using a combination of multiple scintillators with different quenching. Approach. Inorganic and organic scintillator sheets were layered and irradiated with proton beams. Two-color signals of the CMOS sensor were obtained from the scintillation light and calibration curves were generated using LET. LET was calculated using Monte Carlo simulations as LETt and LETd weighted by fluence and dose, respectively. The accuracy of the calibration curve was evaluated by comparing the calculated and measured LET values for the 200 MeV monoenergetic and spread-out Bragg peak (SOBP) beams. LET distributions were obtained from the calibration curves. Main results. The deviation between the calculated and measured LET values was evaluated. For both LETt and LETd, the deviation in the plateau region of the monoenergetic and SOBP beams tended to be larger than those in the peak region. The deviation was smaller for LETd. In the obtained LETd distribution, the deviation between the calculated and measured values agreed within 3% in the peak region, while the deviation was larger in other regions. Significance. The LET distribution can be measured with a single irradiation using two scintillator sheets. This method may be effective for verifying LET in daily clinical practice and for quality control.
引用
收藏
页数:15
相关论文
共 31 条
  • [11] Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning
    Meng-Ya Guo
    Xiu-Fang Li
    Jie Wang
    Qi Liu
    Xiu-Zhen Deng
    Man-Zhou Zhang
    Li-Ren Shen
    Yue-Hu Pu
    Zhi-Ling Chen
    Nuclear Science and Techniques, 2021, 32 (06) : 85 - 95
  • [12] Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning
    Guo, Meng-Ya
    Li, Xiu-Fang
    Wang, Jie
    Liu, Qi
    Deng, Xiu-Zhen
    Zhang, Man-Zhou
    Shen, Li-Ren
    Pu, Yue-Hu
    Chen, Zhi-Ling
    NUCLEAR SCIENCE AND TECHNIQUES, 2021, 32 (06)
  • [13] Characterization of real-time dose measurement using monitor ionization chamber in electron beam FLASH radiotherapy
    Lang, Xinle
    Luo, Faming
    Li, Min
    Zhou, Kai
    Li, Juan
    Hu, Zhenguo
    Mao, Ruishi
    Xu, Zhiguo
    Xiao, Guoqing
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (06)
  • [14] Online monitoring for proton therapy: A real-time procedure using a planar PET system
    Kraan, A. C.
    Battistoni, G.
    Belcari, N.
    Camarlinghi, N.
    Ciocca, M.
    Ferrari, A.
    Ferretti, S.
    Mairani, A.
    Molinelli, S.
    Pullia, M.
    Sala, P.
    Sportelli, G.
    Del Guerra, A.
    Rosso, V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 786 : 120 - 126
  • [15] Characterization of a Gafchromic film for the two-dimensional profile measurement of low-energy heavy-ion beams
    Yuri, Yosuke
    Narumi, Kazumasa
    Yuyama, Takahiro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 828 : 15 - 21
  • [16] TWO-DIMENSIONAL PROMPT GAMMA MEASUREMENT SIMULATION FOR IN VIVO DOSE VERIFICATION IN PROTON THERAPY: A MONTE CARLO STUDY
    Min, Chul Hee
    Lee, Han Rim
    Kim, Chan Hyeong
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 11 - 15
  • [17] Deep learning proton beam range estimation model for quality assurance based on two-dimensional scintillated light distributions in simulations
    Lee, Eunho
    Cho, Byungchul
    Kwak, Jungwon
    Jeong, Chiyoung
    Park, Min-Jae
    Kim, Sung-woo
    Song, Si Yeol
    Goh, Youngmoon
    MEDICAL PHYSICS, 2023, 50 (11) : 7203 - 7213
  • [18] Quantitative, real-time scintillation imaging for experimental comparison of different dose and dose rate estimations in UHDR proton pencil beams
    Clark, Megan
    Harms, Joseph
    Vasyltsiv, Roman
    Sloop, Austin
    Kozelka, Jakub
    Simon, Bill
    Zhang, Rongxiao
    Gladstone, David
    Bruza, Petr
    MEDICAL PHYSICS, 2024, : 6402 - 6411
  • [19] Real-time monitoring of ultra-high dose rate electron beams using bremsstrahlung photons
    Kim, Hyun
    Jeong, Dong Hyeok
    Kang, Sang Koo
    Lee, Manwoo
    Lim, Heuijin
    Lee, Sang Jin
    Jang, Kyoung Won
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (09) : 3417 - 3422
  • [20] Real-time in vivo verification of proton therapy using new Monte Carlo framework for head phantom
    Ganjeh, Zahra Ahmadi
    Campos, Brian Zapien
    Both, Stefan
    Traneus, Erik
    Dendooven, Peter
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4646 - S4649