High-precision MC-ICP-MS measurements of Cd isotopes using a novel double spike method without Sn isobaric interference

被引:0
|
作者
Li, Jin [1 ]
Tang, Suo-han [1 ]
Zhu, Xiangkun [1 ]
Ma, Jian-xiong [1 ]
Zhu, Zhiyong [1 ]
Yan, Bin [1 ]
机构
[1] Chinese Acad Geol Sci, Inst Geol, MNR Key Lab Isotope Geol, Beijing 100037, Peoples R China
基金
美国国家科学基金会;
关键词
GEOLOGICAL REFERENCE MATERIALS; CADMIUM ISOTOPES; SOUTHERN-OCEAN; FRACTIONATION; POLLUTION; SEAWATER; SOILS; ZINC; ABUNDANCES; SEPARATION;
D O I
10.1039/d4ja00357h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Previous studies have reported that even low concentrations of Sn can lead to biased Cd isotopic measurements using MC-ICP-MS. In this paper, we propose a novel method of Cd isotopic analysis involving use of a Cd-106-Cd-111 double spike. To eliminate isobaric interference from Sn-114, we use Cd-113 together with Cd-106, Cd-110, and Cd-111 to obtain delta Cd-113/110, and then calculate delta Cd-114/110 as 1.33 x delta Cd-113/110. We find that when Sn/Cd is <= 2.5 in sample solutions, delta Cd-114/110 values are not affected by Sn, which behaves as a matrix element rather than causing isobaric interference. Cd isotopic measurements are not sensitive to the molarities of diluted HNO3 or the Cd concentration. Additionally, when Mo/Cd, Ni/Cd, and Se/Cd are <= 1 in sample solutions, Cd isotopic measurements are not significantly affected. Instead, when Zn/Cd is >0.1, In/Cd > 0.05, and Pd/Cd > 5 x 10(-3), the measured delta Cd-114/110 values deviate significantly from zero. However, Zn and In can be eliminated completely, and Pd was not detected in any Cd eluents. The delta Cd-114/110 values of three standard solutions (Spex-CUGB, BAM I012, and M & uuml;nster) and four geochemical reference materials (SGR-1b, BCR-2, GSD-7a, and NIST 2711a) were measured and found to be in close agreement with published results (with 2SD and ranges for all data of less than 0.090 and 0.120, respectively). This indicates that the data obtained by our double spike method are precise and reliable. Additionally, our new technique can help to simplify separation procedures, thus saving time and reducing the quantities of acid required.
引用
收藏
页码:3106 / 3115
页数:10
相关论文
共 50 条
  • [41] Titanium Isotope Analysis of Igneous Reference Materials using a Double-spike MC-ICP-MS Method
    Li, Jin
    Tang, Suohan
    Zhu, Xiangkun
    Ma, Jianxiong
    Zhao, Xinmiao
    ACTA GEOLOGICA SINICA-ENGLISH EDITION, 2022, 96 (02) : 517 - 524
  • [42] Measurement on high-precision boron isotope of silicate materials by a single column purification method and MC-ICP-MS
    Wei Gangjian
    Wei Jingxian
    Liu Ying
    Ke Ting
    Ren Zhongyuan
    Ma Jinlong
    Xu Yigang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (04) : 606 - 612
  • [43] High-precision potassium isotope analysis using the Nu Sapphire collision cell (CC)-MC-ICP-MS
    Li, Wenjun
    Cui, Mengmeng
    Pan, Qiqi
    Wang, Jing
    Gao, Bingyu
    Liu, Shanke
    Yuan, Meng
    Su, Benxun
    Zhao, Ye
    Teng, Fang-Zhen
    Han, Guilin
    SCIENCE CHINA-EARTH SCIENCES, 2022, 65 (08) : 1510 - 1521
  • [44] High-precision Mg isotope analyses of low-Mg rocks by MC-ICP-MS
    An, Yajun
    Wu, Fei
    Xiang, Yuanxin
    Nan, Xiaoyun
    Yu, Xun
    Yang, Jinhui
    Yu, Huimin
    Xie, Liewen
    Huang, Fang
    CHEMICAL GEOLOGY, 2014, 390 : 9 - 21
  • [45] High-precision Ca isotopic measurement using a large geometry high resolution MC-ICP-MS with a dummy bucket
    Li, Ming
    Lei, Yv
    Feng, Lanping
    Wang, Zaicong
    Belshaw, Nick S.
    Hu, Zhaochu
    Liu, Yongsheng
    Zhou, Lian
    Chen, Haihong
    Chai, Xinna
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (10) : 1707 - 1719
  • [46] Determining Ba isotopes of barite using the Na2CO3 exchange reaction and double-spike method by MC-ICP-MS
    Tian, Lan-Lan
    Zeng, Zhen
    Nan, Xiao-Yun
    Yu, Hui-Min
    Huang, Fang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (07) : 1459 - 1467
  • [47] Chemical procedure for Zn purification and double spike method for high precision measurement of Zn isotopes by MC-ICPMS
    Amet, Quentin
    Fitoussi, Caroline
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 457
  • [48] High-Precision Fe and Mg Isotope Ratios of Silicate Reference Glasses Determined In Situ by Femtosecond LA-MC-ICP-MS and by Solution Nebulisation MC-ICP-MS
    Oeser, Martin
    Weyer, Stefan
    Horn, Ingo
    Schuth, Stephan
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2014, 38 (03) : 311 - 328
  • [49] High-precision 41K/39K measurements by MC-ICP-MS indicate terrestrial variability of δ41K
    Morgan, Leah E.
    Ramos, Danielle P. Santiago
    Davidheiser-Kroll, Brett
    Faithfull, John
    Lloyd, Nicholas S.
    Ellam, Rob M.
    Higgins, John A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (02) : 175 - 186
  • [50] Copper Isotope Ratio Measurements of Cu-Dominated Minerals Without Column Chromatography Using MC-ICP-MS
    Zhang, Yan
    Bao, Zhian
    Lv, Nan
    Chen, Kaiyun
    Zong, Chunlei
    Yuan, Honglin
    FRONTIERS IN CHEMISTRY, 2020, 8