High-precision MC-ICP-MS measurements of Cd isotopes using a novel double spike method without Sn isobaric interference

被引:0
|
作者
Li, Jin [1 ]
Tang, Suo-han [1 ]
Zhu, Xiangkun [1 ]
Ma, Jian-xiong [1 ]
Zhu, Zhiyong [1 ]
Yan, Bin [1 ]
机构
[1] Chinese Acad Geol Sci, Inst Geol, MNR Key Lab Isotope Geol, Beijing 100037, Peoples R China
基金
美国国家科学基金会;
关键词
GEOLOGICAL REFERENCE MATERIALS; CADMIUM ISOTOPES; SOUTHERN-OCEAN; FRACTIONATION; POLLUTION; SEAWATER; SOILS; ZINC; ABUNDANCES; SEPARATION;
D O I
10.1039/d4ja00357h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Previous studies have reported that even low concentrations of Sn can lead to biased Cd isotopic measurements using MC-ICP-MS. In this paper, we propose a novel method of Cd isotopic analysis involving use of a Cd-106-Cd-111 double spike. To eliminate isobaric interference from Sn-114, we use Cd-113 together with Cd-106, Cd-110, and Cd-111 to obtain delta Cd-113/110, and then calculate delta Cd-114/110 as 1.33 x delta Cd-113/110. We find that when Sn/Cd is <= 2.5 in sample solutions, delta Cd-114/110 values are not affected by Sn, which behaves as a matrix element rather than causing isobaric interference. Cd isotopic measurements are not sensitive to the molarities of diluted HNO3 or the Cd concentration. Additionally, when Mo/Cd, Ni/Cd, and Se/Cd are <= 1 in sample solutions, Cd isotopic measurements are not significantly affected. Instead, when Zn/Cd is >0.1, In/Cd > 0.05, and Pd/Cd > 5 x 10(-3), the measured delta Cd-114/110 values deviate significantly from zero. However, Zn and In can be eliminated completely, and Pd was not detected in any Cd eluents. The delta Cd-114/110 values of three standard solutions (Spex-CUGB, BAM I012, and M & uuml;nster) and four geochemical reference materials (SGR-1b, BCR-2, GSD-7a, and NIST 2711a) were measured and found to be in close agreement with published results (with 2SD and ranges for all data of less than 0.090 and 0.120, respectively). This indicates that the data obtained by our double spike method are precise and reliable. Additionally, our new technique can help to simplify separation procedures, thus saving time and reducing the quantities of acid required.
引用
收藏
页码:3106 / 3115
页数:10
相关论文
共 50 条
  • [11] High-precision MC-ICP-MS static measurements of uranium isotopes using Faraday cups
    Jin, Mangu
    Jiao, Yanuo
    Liu, Yue
    Shao, Qingfeng
    Kong, Xinggong
    Wang, Yongjin
    CHINESE SCIENCE BULLETIN-CHINESE, 2022, 67 (22): : 2651 - 2661
  • [12] High-precision double-spike Cd isotopic measurements of seawater by MC-ICP-MS and its application to seawater affected by hydrothermal vent fluids
    Zhu, Chuanwei
    Wu, Yunzhu
    Wen, Hanjie
    Wu, Guanghai
    Song, Wenrui
    Zhang, Yuxu
    Zhao, Bo
    ACTA GEOCHIMICA, 2023, 42 (05) : 934 - 942
  • [13] High-precision barium isotope measurements by MC-ICP-MS
    Nan, Xiaoyun
    Wu, Fei
    Zhang, Zhaofeng
    Hou, Zhenhui
    Huang, Fang
    Yu, Huimin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (11) : 2307 - 2315
  • [14] High-precision measurement of Ag isotopes for silicate rocks by MC-ICP-MS
    Fang, Yuan
    Wen, Qiu-Yu
    Xiao, Zi-Cong
    Yu, Hui-Min
    Huang, Fang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (07) : 1750 - 1758
  • [15] High-sensitivity determination of Cd isotopes in low-Cd geological samples by double spike MC-ICP-MS
    Tan, Decan
    Zhu, Jian-Ming
    Wang, Xiangli
    Han, Guilin
    Lu, Zhuo
    Xu, Wenpo
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (04) : 713 - 727
  • [16] Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS
    Guo, Chao
    Li, Tao
    Li, Gaojun
    Chen, Tianyu
    Li, Le
    Zhao, Liang
    Ji, Junfeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (11) : 2470 - 2479
  • [17] High-precision double-spike Cd isotopic measurements of seawater by MC-ICP-MS and its application to seawater affected by hydrothermal vent fluids
    Chuanwei Zhu
    Yunzhu Wu
    Hanjie Wen
    Guanghai Wu
    Wenrui Song
    Yuxu Zhang
    Bo Zhao
    Acta Geochimica, 2023, 42 : 934 - 942
  • [18] Isobaric Spike Method for Absolute Isotopic Ratio Determination by MC-ICP-MS
    Shuai, Kang
    Li, Weiqiang
    Hui, Hejiu
    ANALYTICAL CHEMISTRY, 2020, 92 (07) : 4820 - 4828
  • [19] High-precision copper isotopic analysis using a Nu Sapphire MC-ICP-MS
    Wang, Jing
    Su, Ben-Xun
    Tang, Dong-Mei
    Yuan, Qing-Han
    Li, Wen-Jun
    Gao, Bing-Yu
    Bao, Zhi-An
    Zhao, Ye
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (12) : 2589 - 2598
  • [20] High-precision lithium isotopic analysis using the Nu Sapphire MC-ICP-MS
    Liu, Shanke
    Li, Wenjun
    Su, Benxun
    Gao, Bingyu
    Wang, Jing
    Wang, Changle
    Luo, Yang
    Yan, Lizhi
    Zhao, Ye
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (03) : 656 - 666