Development and validation of a chiral LC-MS/MS method for the separation and quantification of four synthetic cathinones in human whole blood and its application in stability analysis

被引:8
|
作者
Aldubayyan A.A. [1 ,2 ]
Castrignanò E. [1 ]
Elliott S. [1 ,3 ]
Abbate V. [1 ]
机构
[1] Department of Analytical, Environmental & Forensic Sciences, Faculty of Life Sciences & Medicine, King's College London, London
[2] Department of Toxicology, Central Military Laboratory and Blood Bank, Prince Sultan Military Medical City, Riyadh
[3] Elliott Forensic Consulting, Birmingham
关键词
Chiral LC-MS/MS; Stability; Synthetic cathinones; Whole blood;
D O I
10.1016/j.talanta.2022.123986
中图分类号
学科分类号
摘要
Synthetic cathinones, a subclass of new psychoactive substances, have gained high popularity on the recreational drugs market over the past years. These drugs typically have a chiral center, so they may exist as two stereoisomers. Therefore the pharmacological, pharmacokinetic or metabolic properties of their enantiomers are expected to differ. However, these drugs are often synthesized and sold as a racemic mixture, and as a consequence, differentiation of their (R)- and (S)- enantiomers is relevant in clinical and forensic toxicology. Information about single enantiomers of synthetic cathinones is relatively scarce due to challenges of their chiral analysis. Hence, a sensitive and reliable liquid chromatography-tandem mass spectrometry method was developed and validated for the chiral separation and quantification of four synthetic cathinones in human whole blood samples. The method was fully validated in terms of linearity, limit of detection, limit of quantification, bias, precision, carryover, interferences, matrix effects, recovery and processed sample stability and successfully applied to evaluate the stability as well as enantioselective degradation of synthetic cathinones enantiomers under various storage conditions. For most of the analytes, significant enantioselective degradation was observed when stored at room temperature or refrigerated, with the E2-enantiomers observed to more rapidly degrade under both conditions. This is the first report concerning the stability and enantioselective degradation of synthetic cathinone enantiomers in whole blood. Moreover, the inversion study demonstrated enantiomeric inversion of R-(−)- and S-(+)-methylenedioxypyrovalerone (MDPV) in human whole blood and methanolic solution. © 2022 The Authors
引用
收藏
相关论文
共 50 条
  • [41] Simultaneous Quantitation of Clevidipine and Its Active Metabolite H152/81 in Human Whole Blood by LC-MS/MS: Application to Bioequivalence Study
    Li, Pengfei
    Wu, Haitang
    Zhao, Zhixia
    Du, Ping
    Xu, Haitong
    Liu, Hongchuan
    Zhou, Yu
    Yu, Weiyue
    Li, Hao
    Liu, Lihong
    FRONTIERS IN CHEMISTRY, 2022, 10
  • [42] Development and validation of an LC-MS/MS method for simultaneous determination of remdesivir and its hydrolyzed metabolite and nucleoside, and its application in a pharmacokinetic study of normal and diabetic nephropathy mice
    Yuan, Meng
    Hu, Wenjuan
    Feng, Yingying
    Tong, Yue
    Wang, Xin
    Tan, Bo
    Xu, Hui
    Liu, Jia
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (07)
  • [43] Determination of four immunosuppressive drugs in whole blood using MEPS and LC-MS/MS allowing automated sample work-up and analysis
    Said, Rana
    Pohanka, Anton
    Abdel-Rehim, Mohamed
    Beck, Olof
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 897 : 42 - 49
  • [44] Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma
    Zhang, Stanley
    Jian, Wenying
    Sullivan, Sheryl
    Sankaran, Banu
    Edom, Richard W.
    Weng, Naidong
    Sharkey, David
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 961 : 62 - 70
  • [45] Development and validation of a fast ionic liquid-based dispersive liquid-liquid microextraction procedure combined with LC-MS/MS analysis for the quantification of benzodiazepines and benzodiazepine-like hypnotics in whole blood
    De Boeck, Marieke
    Missotten, Sophie
    Dehaen, Wim
    Tytgat, Jan
    Cuypers, Eva
    FORENSIC SCIENCE INTERNATIONAL, 2017, 274 : 44 - 54
  • [46] Application of a rapid μ-SPE clean-up for multiclass quantitative analysis of sixteen new psychoactive substances in whole blood by LC-MS/MS
    Montesano, Camilla
    Vannutelli, Gabriele
    Piccirilli, Valeria
    Sergi, Manuel
    Compagnone, Dario
    Curini, Roberta
    TALANTA, 2017, 167 : 260 - 267
  • [47] Development and Validation of a Method for Quantification of 28 Psychotropic Drugs in Postmortem Blood Samples by Modified Micro-QuEChERS and LC-MS-MS
    Rodrigues, Tais B.
    Morais, Damila R.
    Gianvecchio, Victor A. P.
    Aquino, Elvis M.
    Cunha, Ricardo L.
    Huestis, Marilyn A.
    Costa, Jose Luiz
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2021, 45 (07) : 644 - 656
  • [48] Development and validation of a highly sensitive and selective LC-MS/MS method for the determination of 15-hydroxylubiprostone in human plasma: application to a pharmacokinetic study in healthy Chinese volunteers
    Li, Xianjing
    Yu, Haitao
    Guo, Wenjing
    Cheng, Minlu
    Song, Qinxin
    Ding, Li
    XENOBIOTICA, 2022, 52 (06) : 567 - 574
  • [49] Determination of bromadiolone and brodifacoum in human blood using LC-ESI/MS/MS and its application in four superwarfarin poisoning cases
    Yan, Hui
    Xiang, Ping
    Zhu, Lin
    Shen, Min
    FORENSIC SCIENCE INTERNATIONAL, 2012, 222 (1-3) : 313 - 317
  • [50] Development of LC-MS/MS method for quantification of Lurasidone using volumetric absorptive microsampling (VAMS); a comparative study between dried blood and plasma samples
    Rajadhyaksha, Madhura
    Londhe, Vaishali