摘要
Reducing optical losses is crucial for reducing quantum noise in gravitational-wave detectors. In fact, with equal input power, a lower level of round-trip losses in the arm cavities allows more power to be stored. Moreover, losses are the main source of degradation of the squeezed vacuum, which, along with increasing the power, is the most effective strategy to reduce quantum noise. Frequency-dependent squeezing obtained via a filter cavity is currently used to reduce quantum noise over the whole detector bandwidth. Such filter cavities are required to have high finesse in order to produce optimal squeezing angle rotation, and the presence of losses is particularly detrimental for the squeezed beam, as it does multiple round trips within the cavity. Characterizing such losses is crucial to assess the achievable quantum noise reduction. Here we present an in situ measurement of the optical losses, for different positions of the beam on the mirrors of the Virgo filter cavity. We implemented an automatic system to map the losses with respect to the beam position on the mirrors, finding that optical losses depend clearly on the position at which the beam hits the input mirror, varying from 42 to 87 ppm (parts per million), while they are much more uniform when we scan the end mirror (53 to 61 ppm). We repeated the measurements on several days, finding a statistical error less than +/- 4 ppm. The lowest measured losses are not much different from those estimated by individual mirror characterization performed before installation (30.3-39.3 ppm). This means that no major loss mechanism has been neglected in the estimation presented here. The larger discrepancy found for some beam positions is likely to be due to contamination. In addition to a thorough characterization of the losses, the methodology described herein allowed an optimal cavity axis position to be found for which the cavity round-trip losses are among the lowest ever measured. This work can contribute to achieving the very challenging loss goals for the optical cavities of future gravitational-wave detectors, such as the Einstein Telescope and Cosmic Explorer.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Optical response of a misaligned and suspended Fabry-Perot cavity
    Cella, G.
    Di Virgilio, A.
    La Penna, P.
    D'Auria, V.
    Porzio, A.
    Ricciardi, I.
    Solimeno, S.
    PHYSICAL REVIEW A, 2006, 74 (01):
  • [2] NOISE PERFORMANCE OF A 72 m SUSPENDED FABRY-PEROT CAVITY
    Dumas, Jean-Charles
    Ju, Li
    Barriga, Pablo
    Zhao, Chunnong
    Woolley, Andrew A.
    Blair, David G.
    INTERNATIONAL JOURNAL OF MODERN PHYSICS D, 2011, 20 (10): : 2063 - 2067
  • [3] Performance of a 1200 m long suspended Fabry-Perot cavity
    Freise, A
    Casey, MM
    Gossler, S
    Grote, H
    Heinzel, G
    Lück, H
    Robertson, DI
    Strain, KA
    Ward, H
    Willke, B
    Hough, J
    Danzmann, K
    CLASSICAL AND QUANTUM GRAVITY, 2002, 19 (07) : 1389 - 1397
  • [4] Diffraction losses of a Fabry-Perot cavity with nonidentical non-spherical mirrors
    Poplavskiy, Mikhail, V
    Matsko, Andrey B.
    Yamamoto, Hiroaki
    Vyatchanin, Sergey P.
    JOURNAL OF OPTICS, 2020, 22 (11)
  • [5] Alignment locking to suspended Fabry-Perot cavity
    Bram J. J. Slagmolen
    Mark Barton
    Conor Mow-Lowry
    Glenn de Vine
    David S. Rabeling
    Jong H. Chow
    Albert Romann
    Chunnong Zhao
    Malcolm B. Gray
    David E. McClelland
    General Relativity and Gravitation, 2005, 37 : 1601 - 1608
  • [6] Alignment locking to suspended Fabry-Perot cavity
    Slagmolen, BJJ
    Barton, M
    Mow-Lowry, C
    de Vine, G
    Rabeling, DS
    Chow, JH
    Romann, A
    Zhao, CN
    Gray, MB
    McClelland, DE
    GENERAL RELATIVITY AND GRAVITATION, 2005, 37 (09) : 1601 - 1608
  • [7] Critical coupling in a Fabry-Perot cavity with metamaterial mirrors
    Deb, Subimal
    Gupta, S. Dutta
    OPTICS COMMUNICATIONS, 2010, 283 (23) : 4764 - 4769
  • [8] Guided lock acquisition in a suspended Fabry-Perot cavity
    Camp, J
    Sievers, L
    Rolf, B
    Heefner, J
    OPTICS LETTERS, 1995, 20 (24) : 2463 - 2465
  • [9] Active vibration suppression in a suspended Fabry-Perot cavity
    Canuto, Enrico
    ISA TRANSACTIONS, 2006, 45 (03) : 329 - 346
  • [10] Active vibration suppression in a suspended Fabry-Perot cavity
    Canuto, ES
    Rolino, A
    PROCEEDINGS OF THE 2004 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2004, : 5698 - 5703