Visual simulation of intraocular lenses: from on-bench performance to computational and experimental validations

被引:1
|
作者
Rapadogiannis, Petros [1 ]
Gambra, Enrique [1 ]
Labuz, Grzegorz [2 ]
Yan, Weijia [2 ,3 ]
Martin-becerra, Diana [1 ]
Siso-Fuertes, Irene [1 ]
De Castro, Alberto [4 ]
Barcala, Xoana [1 ]
Auffarth, Gerd U. [2 ]
Dorronsoro, Carlos [1 ,4 ]
Sawides, Lucie [4 ]
机构
[1] 2EyesVis SL, Madrid, Spain
[2] Univ Hosp Heidelberg, David J Apple Ctr Vis Res, Dept Ophthalmol, INF 400, D-69120 Heidelberg, Germany
[3] Zhejiang Univ, Affiliated Hosp 2, Eye Ctr, Sch Med, Hangzhou 310009, Peoples R China
[4] Spanish Natl Res Council, Inst Opt, CSIC, Madrid, Spain
来源
BIOMEDICAL OPTICS EXPRESS | 2024年 / 15卷 / 11期
关键词
LONGITUDINAL CHROMATIC ABERRATION; IMAGE QUALITY; ACUITY; METRICS; DESIGN; FOCUS;
D O I
10.1364/BOE.538878
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study presents a systematic method to simulate various intraocular lenses (IOLs) available in the market. Five IOLs (two trifocals, one bifocal, one enhanced monofocal, and one extended depth of focus (EDOF)) were evaluated in terms of through focus visual Strehl (TFVS) utilizing the OptiSpheric IOL PRO2 device (Trioptics GmbH). Then, the estimated TFVS (ETFVS) and the temporal coefficients necessary for temporal multiplexing were computed, and through an iterative process, the SimVis TFVS was obtained. Finally, a high-speed focimeter was used to measure the opto-tunable lens responses to the temporal profile, and the experimental SimVis TFVS was acquired. Therefore, results are analyzed in terms of ETFVS (computed from the VSR-OTF), SimVis TFVS (computed from the TCs through temporal multiplexing), and experimental SimVis TFVS (acquired from the high-speed focimeter setup). The ETFVS and the SimVis TFVS curves demonstrated excellent alignment across all IOLs with cross-correlation coefficients > 0.94. Similarly, the experimental SimVis TFVS and the SimVis TFVS curves showed high correlation with cross-correlation coefficients > 0.97 and root mean square error (RMSE) < 0.05 for each lens. We demonstrated that different IOL designs can be visually simulated using its TFVS to obtain the corresponding temporal coefficients for simulations through temporal multiplexing using the SimVis technology.
引用
收藏
页码:6521 / 6530
页数:10
相关论文
共 29 条
  • [1] Visually relevant on-bench through-focus analysis of intraocular lenses
    Ginis, Harilaos s.
    Tsoukalas, Spyridon
    Christaras, Dimitrios
    Artal, Pablo
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (12): : 7056 - 7065
  • [2] Comparison of Five Presbyopia-Correcting Intraocular Lenses: Optical-Bench Assessment with Visual-Quality Simulation
    Labuz, Grzegorz
    Yan, Weijia
    Baur, Isabella D. D.
    Khoramnia, Ramin
    Auffarth, Gerd U. U.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (07)
  • [3] Visual simulation of intraocular lenses: technologies and applications [Invited]
    Marcos, Susana
    Artal, Pablo
    Lundstroem, Linda
    Yoon, Geunyoung
    BIOMEDICAL OPTICS EXPRESS, 2025, 16 (03): : 1025 - 1042
  • [4] Correlating Optical Bench Performance With Clinical Defocus Curves in Varifocal and Trifocal Intraocular Lenses
    Plaza-Puche, Ana B.
    Alio, Jorge L.
    MacRae, Scott
    Zheleznyak, Len
    Sala, Esperanza
    Yoon, Geunyoung
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (05) : 300 - +
  • [5] Visual performance with accommodating and multifocal intraocular lenses
    Lan, Jie
    Huang, Yu-Sen
    Dai, Yun-Hai
    Wu, Xiao-Ming
    Sun, Jia-Jun
    Xie, Li-Xin
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (02) : 235 - 240
  • [6] Optical bench simulation for intraocular lenses using field-tracing technology
    Song, Seok Ho
    Song, In Seok
    Oh, Se Jin
    Son, Hyeck-Soo
    Kang, Min Ho
    PLOS ONE, 2021, 16 (12):
  • [7] Impact of pupil size and corneal spherical aberrations on the performance of monofocal intraocular lenses: an experimental model
    Stern, Benjamin
    Gatinel, Damien
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (11): : 6433 - 6448
  • [8] Visual performance of aspherical and spherical intraocular lenses:: Intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations
    Kasper, Thomas
    Buehren, Jens
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) : 2022 - 2029
  • [9] Changes in visual performance after implantation of different intraocular lenses
    Li, Bo-Wen
    Huang, Hao
    Huang, Man-Sha
    Guo, Shuang-Lin
    Gao, Lu
    Zeng, Yu-Ying
    Cheng, Lu
    Yao, Si-Yang
    Lin, Jian-Qiang
    Liu, Lin
    Yang, Ye
    Lu, Xiao-Ming
    Cheng, Hao
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (07) : 1273 - 1282
  • [10] Visual performance following implantation of presbyopia correcting intraocular lenses
    Torky, Magda A.
    El Nokrashy, Amgad
    Metwally, Heba
    Abdelhameed, Ameera G.
    EYE, 2022, 39 (1) : 79 - 87