Research on the performance of ultra-low temperature cascade refrigeration system based on low GWP refrigerants

被引:0
|
作者
Zhang, Chaoxu [1 ,2 ]
Xin, Gongming [1 ,2 ]
Yan, Gang [3 ]
Zhao, Hongxia [1 ,2 ]
Han, Jitian [1 ,2 ]
Li, Zengqun [4 ]
Ju, Chengcheng [4 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Peoples R China
[2] Shandong Engn Res Ctr High Efficiency Energy Stora, Jinan 250061, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
[4] Moon Environm Technol Co Ltd, Yantai 264000, Shandong, Peoples R China
关键词
Ultra-low temperature; Cascade refrigeration systems; Low GWP; Performance; Exergy; THERMODYNAMIC ANALYSIS; EXERGY ANALYSIS; MULTIOBJECTIVE OPTIMIZATION; THEORETICAL-ANALYSIS; ENERGY; R1234YF; R134A; ALTERNATIVES; REPLACEMENT; R1234ZE(E);
D O I
10.1016/j.icheatmasstransfer.2024.108232
中图分类号
O414.1 [热力学];
学科分类号
摘要
The EU Security Council and Parliament have tentatively agreed to ban fluorinated gases with a global warming potential (GWP) higher than 150 in split air conditioners and heat pumps from 2027. This will further motivate the refrigeration industry to accelerate the search for refrigerants with low GWP and zero ozone depletion potential (ODP). At present, research into low GWP refrigerants for cascade systems is limited, focusing mainly on single refrigerant substitutes without comprehensive comparisons and lax GWP restrictions. In this study, the cascade refrigeration cycle (CRS) system is established to meet the demand of -100 to -50 degrees C. The GWP of the refrigerants is strictly controlled below 150, and a comprehensive screening of the four generations of refrigerants is carried out to identify refrigerant pairs that meet environmental and refrigeration requirements. The relationship between the high-temperature cycle (HTC) evaporation temperature and the optimal coefficient of performance (COP) is determined, and the effects of the low-temperature cycle (LTC) evaporation temperature T-e concerning with mass flow rate, discharge temperature of compressor, compressor power consumption, exergy destruction, and exergy efficiency are analyzed in detail. The thermodynamically superior refrigerant pairs are identified by comparison with several conventional refrigerant pairs. The results show that when T-e > -67 degrees C, R170/R600a is preferred, and when T-e <= -67 degrees C, R170/R1270 is preferred. In the temperature range of -100 similar to -50 degrees C, R170/R1270 is the better refrigerant pair, which can improve the performance by 6.39-13.11 % than traditional refrigerant pairs. Finally, the exergy destruction analysis of CRS components is carried out, which provides a reference for refrigerant selection and system optimization of CRS in the field of ULT.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Energy and exergy analysis of low GWP refrigerants in cascade refrigeration system
    Sun, Zhili
    Wang, Qifan
    Xie, Zhiyuan
    Liu, Shengchun
    Su, Dandan
    Cui, Qi
    ENERGY, 2019, 170 : 1170 - 1180
  • [2] Utilization of ultra-low temperature heat by a novel cascade refrigeration system with environmentally-friendly refrigerants
    He, Yijian
    Jiang, Yunyun
    Fan, Yuchen
    Chen, Guangming
    Tang, Liming
    RENEWABLE ENERGY, 2020, 157 : 204 - 213
  • [3] Thermodynamic assessment of a triple cascade refrigeration system utilizing hydrocarbon refrigerants for ultra-low temperature applications
    Faruque, Md Walid
    Nabil, Mahdi Hafiz
    Uddin, Mohammed Raihan
    Ehsan, M. Monjurul
    Salehin, Sayedus
    ENERGY CONVERSION AND MANAGEMENT-X, 2022, 14
  • [4] Novel Design and Thermodynamic Analyses of Cascade Refrigeration System at Ultra-Low Temperature
    Tan, Husamettin
    Erisen, Ali
    INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2022, 25 (01) : 142 - 150
  • [5] Review of Systems and Refrigerants for Ultra-low Temperature Refrigeration
    Liu, Rui
    Bacellar, Daniel
    Aute, Vikrant
    ASHRAE TRANSACTIONS 2023, VOL 129, PT 1, 2023, 129 : 200 - 207
  • [6] Energy, exergy, environmental and exergoeconomic (4E) analysis of an ultra-low temperature cascade refrigeration system with environmental-friendly refrigerants
    Ji, Shenrui
    Liu, Zhan
    Pan, Hao
    Li, Xiaozhao
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [7] Optimizing cascade refrigeration systems with low GWP refrigerants for Low-Temperature Applications: A thermodynamic analysis
    Arefin, Md. Miraj
    Mondal, Dipayan
    Islam, Md. Ashraful
    ENERGY CONVERSION AND MANAGEMENT-X, 2024, 24
  • [8] Application of response surface methodology and desirability approach to optimize the performance of an ultra-low temperature cascade refrigeration system
    Ye, Wenlian
    Liu, Fazhu
    Yan, Yuqin
    Liu, Yingwen
    APPLIED THERMAL ENGINEERING, 2024, 239
  • [9] Energy, exergoeconomic and environmental optimization of a cascade refrigeration system using different low GWP refrigerants
    Deymi-Dashtebayaz, Mahdi
    Sulin, Alexander
    Ryabova, Tatyana
    Sankina, Iuliia
    Farahnak, Mehdi
    Nazeri, Reza
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (06):
  • [10] Parametric analysis and performance prediction of an ultra-low temperature cascade refrigeration freezer based on an artificial neural network
    Ye, Wenlian
    Yan, Yuqin
    Zhou, Zhongyou
    Yang, Peng
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 55