Performance of a Radio-Frequency Two-Photon Atomic Magnetometer in Different Magnetic Induction Measurement Geometries

被引:0
|
作者
Rushton, Lucas Martin [1 ]
Ellis, Laura Mae [1 ]
Zipfel, Jake David [1 ]
Bevington, Patrick [1 ]
Chalupczak, Witold [1 ]
机构
[1] Natl Phys Lab, Hampton Rd, Teddington TW11 0LW, England
关键词
atomic magnetometer; non-destructive testing; magnetic induction tomography;
D O I
10.3390/s24206657
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Measurements monitoring the inductive coupling between oscillating radio-frequency magnetic fields and objects of interest create versatile platforms for non-destructive testing. The benefits of ultra-low-frequency measurements, i.e., below 3 kHz, are sometimes outweighed by the fundamental and technical difficulties related to operating pick-up coils or other field sensors in this frequency range. Inductive measurements with the detection based on a two-photon interaction in rf atomic magnetometers address some of these issues as the sensor gains an uplift in its operational frequency. The developments reported here integrate the fundamental and applied aspects of the two-photon process in magnetic induction measurements. In this paper, all the spectral components of the two-photon process are identified, which result from the non-linear interactions between the rf fields and atoms. For the first time, a method for the retrieval of the two-photon phase information, which is critical for inductive measurements, is also demonstrated. Furthermore, a self-compensation configuration is introduced, whereby high-contrast measurements of defects can be obtained due to its insensitivity to the primary field, including using simplified instrumentation for this configuration by producing two rf fields with a single rf coil.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] A RADIO-FREQUENCY METHOD FOR THE MEASUREMENT OF INITIAL MAGNETIC-SUSCEPTIBILITY
    COOKE, MP
    DESA, A
    GEOPHYSICAL JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY, 1981, 65 (01): : 272 - 272
  • [32] A RADIO-FREQUENCY METHOD FOR THE MEASUREMENT OF INITIAL MAGNETIC-SUSCEPTIBILITY
    COOKE, MP
    DESA, A
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (10): : 1192 - 1196
  • [33] Different Configurations of Radio-Frequency Atomic Magnetometers-A Comparative Study
    Bevington, Patrick
    Chalupczak, Witold
    SENSORS, 2022, 22 (24)
  • [34] Absolute atomic hydrogen densities in a radio frequency discharge measured by two-photon laser induced fluorescence imaging
    Chérigier, L
    Czarnetzki, U
    Luggenhölscher, D
    Schulz-von der Gathen, V
    Döbele, HF
    JOURNAL OF APPLIED PHYSICS, 1999, 85 (02) : 696 - 702
  • [35] AN EVALUATION OF INDUCTION-COUPLED RADIO-FREQUENCY PLASMA TORCH FOR ATOMIC EMISSION AND ATOMIC ABSORPTION SPECTROMETRY
    VEILLON, C
    MARGOSHES, M
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1968, B 23 (08) : 503 - +
  • [36] Two-photon radio frequency spectroscopy of 49S Rydberg state
    Li Jing-Kui
    Yang Wen-Guang
    Song Zhen-Fei
    Zhang Hao
    Zhang Lin-Jie
    Zhao Jian-Ming
    Jia Suo-Tang
    ACTA PHYSICA SINICA, 2015, 64 (16)
  • [37] Improved sensitivity for two-photon frequency-domain lifetime measurement
    Estrada, Arnold D.
    Dunn, Andrew K.
    OPTICS EXPRESS, 2010, 18 (13): : 13631 - 13639
  • [38] Enhancement of Squeezing in Two-Photon Jaynes-Cummings Model with Atomic Measurement
    YE Sai-Yun Department of Elect
    Communications in Theoretical Physics, 2006, 45 (01) : 147 - 150
  • [39] Enhancement of squeezing in two-photon Jaynes-Cummings model with atomic measurement
    Ye, SY
    COMMUNICATIONS IN THEORETICAL PHYSICS, 2006, 45 (01) : 147 - 150
  • [40] Role of the primary radio frequency magnetic field distribution in atomic magnetometer based inductive measurements
    Bevington, P.
    Wright, L.
    Gartman, R.
    Chalupczak, W.
    JOURNAL OF APPLIED PHYSICS, 2022, 131 (16)