Calculation Model of Winding Loss of Litz-Wire Based on Equivalent Complex Permeability

被引:0
|
作者
Zhao Z. [1 ,2 ]
Wang L. [1 ,2 ]
Chen T. [1 ,2 ]
Zhao A. [1 ,2 ]
Lu Z. [1 ,2 ]
机构
[1] State Key Laboratory of Reliability and Intelligence of Electrical Equipment Hebei University of Technology, Tianjin
[2] Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability of Hebei Province Hebei University of Technology, Tianjin
关键词
equivalent complex permeability; Litz-wire; proximity effect; skin effect; winding loss;
D O I
10.19595/j.cnki.1000-6753.tces.222170
中图分类号
学科分类号
摘要
Asan important component of the overall loss of high-frequency transformers, winding loss is a key parameter affecting the volume, efficiency, and temperature rise of magnetic components. Litz-wire is widely used in high-frequency transformer winding because of its ability to achieve conductor in-turn transposition and reduce losses due to the skin effect and proximity effect. The homogenization technique, using a region with the equivalent complex material properties instead of the winding region, can realize the characterization of the eddy current effect by the two-dimensional magnetic field and reduce the computational cost of refinement modeling. However, the material properties of the equivalent region are obtained using numerical methods, making the calculation complex. Therefore, this paper establishes a loss calculation model of Leeds wire winding based on equivalent complex permeability to calculate winding losses accurately and efficiently. Firstly, the winding loss calculation model is established based on the orthogonality of the skin and proximity effects. The equivalent complex permeability of the winding is calculated using the factory data of the Litz-wire. Then, the overall modeling of Litz-wire winding is carried out in the simulation software, and the external magnetic field value of the winding is extracted for the proximity effect loss calculation. Finally, the skin effect loss is calculated using the analytical formula. The actual winding model of AC resistance in the wide frequency (20 Hz~1 MHz) range shows that AC resistance in the low-frequency band (20 Hz~100 kHz)is approximately equal to DC resistance. At this time, the calculation error can be almost neglected, and the calculation accuracy mainly depends on the calculated value of the DC resistance. The skin effect in the medium-frequency band (100 kHz~500 kHz) becomes gradually obvious, and AC resistance rises rapidly. The highest error is around 300 kHz, and the maximum is 10.07%. In the high-frequency band (500 kHz~1 MHz), the proximity effect between the winding makes the AC resistance rise rapidly. The maximum error in the high-frequency band is 15.22%, and the error in the rest of the frequency is about 10%. The following conclusions can be obtained: (1) By describing the equivalent complex permeability of the circular Litz-wire winding analytically, the preprocessing of the basic unit is avoided, and the calculation process is simplified. (2) The homogenized finite element method is used for overall modeling. The eddy current is analyzed in the three-dimensional structure of the Litz-wire winding based on the two-dimensional static magnetic field distribution and combined with the complex permeability model. The calculation accuracy and speed are improved. (3) Considering the influence of the winding section shape on the loss, the skin effect and proximity effect are characterized, increasing the applicability of the model at high frequency and realizing the accurate loss prediction at wide frequency. © 2024 China Machine Press. All rights reserved.
引用
收藏
页码:947 / 955
页数:8
相关论文
共 24 条
  • [1] Mogorovic M, Dujic D., 100 kW, 10 kHz medium-frequency transformer design optimization and experimental verification, IEEE Transactions on Power Electronics, 34, 2, pp. 1696-1708, (2019)
  • [2] She Xu, Huang A Q, Burgos R., Review of solid-state transformer technologies and their application in power distribution systems, IEEE Journal of Emerging and Selected Topics in Power Electronics, 1, 3, pp. 186-198, (2013)
  • [3] Zhao Yikun, Zhang Guoqiang, Han Dong, Et al., An insulation test method based on the dielectric insulation life for windings in high-frequency transformer, Transactions of China Electrotechnical Society, 35, 13, pp. 2932-2939, (2020)
  • [4] Sun Kai, Lu Shilei, Yi Zheyuan, Et al., A review of high-power high-frequency transformer technology for power electronic transformer applications, Proceedings of the CSEE, 41, 24, pp. 8531-8545, (2021)
  • [5] Zhang Ke, Cao Xiaopeng, Qiao Guangyao, Et al., Analysis of winding loss calculation methods for high frequency transformers, Proceedings of the CSEE, 39, 18, pp. 5536-5546, (2019)
  • [6] Wang Yingying, Cheng Hong, Dual multi-winding high-frequency transformer equivalent circuit for power converter applications, Transactions of China Electrotechnical Society, 36, 19, pp. 4140-4147, (2021)
  • [7] Hu Yi, Zhou Xiaosheng, Research on the application development of Litz winding wire, Shanghai Dazhongxing Dianji, 3, pp. 27-31, (2021)
  • [8] Zhang R Y, White J K, Kassakian J G., Fast simulation of complicated 3-D structures above lossy magnetic media, IEEE Transactions on Magnetics, 50, 10, pp. 1-16, (2014)
  • [9] Dowell P L., Effects of eddy currents in transformer windings, Proceedings of the Institution of Electrical Engineers, 113, 8, (1966)
  • [10] Tourkhani F, Viarouge P., Accurate analytical model of winding losses in round Litz wire windings, IEEE Transactions on Magnetics, 37, 1, pp. 538-543, (2001)