Advanced dual mixed refrigerant (DMR) natural gas liquefaction plant with liquid air: Focus on configuration and optimization

被引:6
作者
Mun, Haneul [1 ]
Kim, Dohee [2 ]
Park, Jinwoo [1 ,2 ]
Lee, Inkyu [1 ,3 ]
机构
[1] Pusan Natl Univ, Sch Chem Engn, Busandaehak Ro 63 Beon Gil 2, Busan 46241, South Korea
[2] Dongguk Univ, Dept Chem & Biochem Engn, 30 Pildong Ro,1 Gil, Seoul 04620, South Korea
[3] Inst Environm & Energy, 2 Busandaehak Ro,63 Beon Gil, Pusan 46241, South Korea
基金
新加坡国家研究基金会;
关键词
LNG supply chain; Cold energy recovery; Natural gas liquefaction; Liquid air; Dual mixed refrigerant process; ENERGY-STORAGE; SELECTION; SINGLE;
D O I
10.1016/j.energy.2024.133747
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study introduces a novel approach to integrating LNG cold energy into the dual mixed refrigerant (DMR) process, employing liquid air as a cold energy carrier. The DMR process is chosen for natural gas liquefaction due to its flexibility in adjusting mixed refrigerant compositions when external cold sources are utilized. Two configurations are investigated: the low-pressure liquid air (LPLA) process, which relies solely on heat exchange, and the high-pressure liquid air (HPLA) process, which involves the pressurization and expansion of liquid air. Additionally, two optimization strategies are explored: 'With Composition' (WC) optimization, which includes refrigerant composition as a variable, and 'Without Composition' (WOC) optimization, which does not. Utilizing liquid air reduces the load on the refrigeration cycle, leading to improved performance compared to the conventional DMR process. The air expansion generates additional power and cold energy, while WC optimization further reduces the flow rate of low-boiling point components, significantly lowering compression energy consumption. As a result, the DMR-HPLA-WC process achieves a 44.17 % reduction in energy consumption, an 8.7 % improvement in exergy efficiency, and a 37.63 % decrease in specific costs.
引用
收藏
页数:15
相关论文
共 43 条
[1]  
[Anonymous], 2003, Selection and costing of heat exchangers: plate-fin type
[2]  
[Anonymous], 1994, ESDU data item No. 94042
[3]  
[Anonymous], 2019, The Role of Gas in Today's Energy Transitions
[4]  
[Anonymous], 2023, World Energy Outlook 2022
[5]  
Baxter L, 2021, Cryogenic carbon CaptureTM (CCC) status report
[6]  
chemengonline, The Chemical Engineering Plant Cost Index ®-Chemical Engineering
[7]   LNG freight rate and LNG price, carbon price, geopolitical risk: A dynamic connectedness analysis [J].
Chen, Yanhui ;
Zhou, Xiaoyu ;
Chen, Shun ;
Mi, Jackson Jinhong .
ENERGY, 2024, 302
[8]  
Feng Y, 2011, CHEM ENG-NEW YORK, V118, P22
[9]  
Fguiri A, 2017, Int J Energy Environ Econ, V25, P269
[10]  
Fritz Pierre, 2017, United States patent US, Patent No. 20170010041