Predicting distribution of aeolian vibration amplitude of undamped overhead transmission lines

被引:1
|
作者
Yang S. [1 ]
Chouinard L. [1 ]
Langlois S. [2 ]
Van Dyke P. [3 ]
Paradis J. [3 ]
机构
[1] Department of Civil Engineering, McGill University, Macdonald Engineering Building, 817 Sherbrooke St W, Room 398, Montreal, H3A 0C3, QC
[2] Department of Civil and Building Engineering, Université de Sherbrooke, Sherbrooke
[3] Institut de recherche d'Hydro-Québec (IREQ), Varennes
基金
加拿大自然科学与工程研究理事会;
关键词
Aeolian vibration; Damage accumulation; Overhead conductor; Residual life; Vibration profile;
D O I
10.1016/j.jweia.2024.105779
中图分类号
学科分类号
摘要
The most widely accepted estimation procedure of the severity of aeolian vibration is by calculating the maximum oscillation amplitudes of the conductor using Energy Balance Principle (EBP). However, the EBP is based on wind tunnel results where only one frequency is excited, while observations and experimental results show that multiple resonant modes are excited simultaneously. Furthermore, the required number of cycles of each amplitude level is not provided by current EBP-based methods. In this paper, vibration data from an experimental undamped ACSR Bersfort test line in Quebec, Canada, is recorded and analyzed. For each record of aeolian vibrations, amplitudes are fitted to a Rayleigh distribution based on the narrow-band assumption. The number of cycles and Rayleigh parameter are then related to wind conditions through a modified Strouhal frequency and EBP methodology. A statistical model is proposed to relate vibration profiles and wind input while considering wind turbulence intensity. The proposed method performs well and gives accurate estimates of both vibration amplitudes and number of cycles for ACSR Bersfort conductor. Physical and statistical theory is provided for each step of the method in order to extend the application of the method to other types of conductors or different line configurations. © 2024 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [21] Galloping Vibration Monitoring of Overhead Transmission Lines by Chirped FBG Array
    Yan, Qizhong
    Zhou, Ciming
    Feng, Xuebin
    Deng, Chi
    Hu, Wenyu
    Xu, Yimin
    PHOTONIC SENSORS, 2022, 12 (03)
  • [22] Estimation of stresses in atmospheric ice during aeolian vibration of power transmission lines
    Kermani, Majid
    Farzaneh, Masoud
    Kollar, Laszlo E.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2010, 98 (10-11) : 592 - 599
  • [23] Statistical Study of Aeolian Vibration Characteristics of Overhead Conductor
    Yang, Shaoqi
    Chouinard, Luc
    Langlois, Sebastien
    Paradis, Josee
    Van Dyke, Pierre
    DYNAMICS AND AERODYNAMICS OF CABLES, ISDAC 2023, 2024, 399 : 99 - 108
  • [24] Method for the Development of Galloping Distribution Maps for Overhead Transmission Lines
    Yang, Jialun
    Liu, Bin
    Zhao, Bin
    Liu, Yaduo
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (06) : 5956 - 5958
  • [25] Experimental and Numerical Analysis of Overhead Transmission Lines Vibration due to Atmospheric Icing
    Liu, Bin
    Ji, Kunpeng
    Zhan, Xueping
    Fei, Xiangze
    Li, Peng
    Zhao, Bin
    Deng, Chun
    Liu, Liang
    Dong, Yongxing
    Wang, Zhili
    Luo, Yongqin
    Bai, Yang
    2017 PROGNOSTICS AND SYSTEM HEALTH MANAGEMENT CONFERENCE (PHM-HARBIN), 2017, : 1117 - 1120
  • [26] PROTECTIO OF OVERHEAD TRANSMISSION LINES
    Chladny, Vladimir
    PROCEEDINGS OF THE 6TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2005, 2005, : 221 - 228
  • [27] Vibration damping by a continuous distribution of undamped oscillators
    Nagem, RJ
    Veljkovic, I
    Sandri, G
    JOURNAL OF SOUND AND VIBRATION, 1997, 207 (03) : 429 - 434
  • [28] Monitoring of overhead transmission lines
    Wilson, M. S.
    Hurlebaus, S.
    STRUCTURAL HEALTH MONITORING 2007: QUANTIFICATION, VALIDATION, AND IMPLEMENTATION, VOLS 1 AND 2, 2007, : 443 - 450
  • [29] Vibration damping by a continuous distribution of undamped oscillators
    Boston Univ, Boston, United States
    J Sound Vib, 3 (429-434):
  • [30] Galloping Amplitude Analysis and Observation on Full-scale Test Overhead Transmission Lines
    Liu, Y. K.
    Fu, Z. C.
    Yang, X. H.
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,