Investigation on Performance of Internally Cooled Liquid Desiccant Dehumidifier Based on ANN Model

被引:0
|
作者
Luo, Yimo [1 ]
Chang, Yayin [1 ]
Li, Nianping [1 ]
机构
[1] College of Civil Engineering, Hunan University, Changsha
来源
Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences | 2024年 / 51卷 / 09期
关键词
liquid desiccant dehumidifier; machine learning; neural networks(NN); parameterization investigation;
D O I
10.16339/j.cnki.hdxbzkb.2024100
中图分类号
学科分类号
摘要
Liquid desiccant dehumidifiers have received widespread attention due to their ability to utilize low-grade thermal energy and high dehumidification efficiency. However,the prediction accuracy of their mass transfer performance still needs to be improved. This article built up an experimental platform of a single-channel internally cooled liquid desiccant dehumidifier to study the effects of different parameters on its mass transfer efficiency. Meanwhile,an artificial neural network(ANN)model was established with MATLAB to predict the mass transfer efficiency of the dehumidifier. The ANN model was verified and validated with the above experimental data. The results indicated that the a mean absolute relative difference(MARD)between the predicted Sh of the ANN model and the experimental Sh was 4.07%. Compared with existing empirical formulas,the ANN model established in this paper had higher prediction accuracy. In addition,this article also used the ANN model to study the trend of Sh under different parameter changes,thereby investigating the impact of different parameters on the dehumidification performance. © 2024 Hunan University. All rights reserved.
引用
收藏
页码:198 / 205
页数:7
相关论文
共 24 条
  • [1] GOSWAMI D Y., Experimental study of the heat and mass transfer in a packed bed liquid desiccant air dehumidifier [J], Journal of Solar Energy Engineering, 120, 4, pp. 289-297, (1998)
  • [2] GONG Y Q,, DENG J, ZHANG W Y, Design of air conditioning system of aircraft air conditioning support equipment based on inner-cooling dehumidification, Journal of Academy of Armored Force Engineering, 31, 1, pp. 74-77, (2017)
  • [3] AN H P, FANG L, Energy consumption analysis of liquid desiccant air conditioning in industrial buildings, J]Energy Conservation, 36, 8, pp. 51-54, (2017)
  • [4] DING Z X, On-site measurement and simulation investigation on condensation dehumidification and desiccant dehumidification in Hong Kong [J], Energy and Buildings, 254, (2022)
  • [5] CHEN Y Y, Performance and optimization of a novel solar-driven liquid desiccant air conditioning system suitable for extremely hot and humid climates, Energy Conversion and Management, 215, (2020)
  • [6] LEE J H, JUNG C W,, CHANG Y S, Nu and Sh correlations for LiCl solution and moist air in plate type dehumidifier, J]International Journal of Heat and Mass Transfer, 100, pp. 433-444, (2016)
  • [7] AL-NAJEM N M., A numerical solution for cooling and dehumidification of air by a falling desiccant film in parallel flow[J], Renewable Energy, 13, 3, pp. 305-322, (1998)
  • [8] CHUNG T W,, GHOSH T K, HINES A L., Comparison between random and structured packings for dehumidification of air by lithium chloride solutions in a packed column and their heat and mass transfer correlations [J], Industrial & Engineering Chemistry Research, 35, 1, pp. 192-198, (1996)
  • [9] DONG C S, ZHANG L Z., Development of liquid-air mass transfer correlations for liquid desiccant dehumidification considering the liquid/air contact and film instability, J]International Journal of Heat and Mass Transfer, 141, pp. 491-502, (2019)
  • [10] WEN T, WANG M, Comparative study on the liquid desiccant dehumidification performance of lithium chloride and potassium formate[J], Renewable Energy, 167, pp. 841-852, (2021)