Evaluation of Two Particle Number (PN) Counters with Different Test Protocols for the Periodic Technical Inspection (PTI) of Gasoline Vehicles

被引:1
|
作者
Melas, Anastasios [1 ]
Franzetti, Jacopo [1 ,2 ]
Suarez-Bertoa, Ricardo [1 ]
Giechaskiel, Barouch [1 ]
机构
[1] European Commiss, Joint Res Ctr JRC, I-21027 Ispra, Italy
[2] Univ Politecn Madrid, Min & Energy Engn Sch, c Rios Rosas 21, Madrid 28003, Spain
关键词
in-use vehicle emissions; petrol car; GDI; PFI; PN-PTI; diffusion charger; condensation particle counter; sub-23 nm particles; AEROSOL; PERFORMANCE; SIZE; PRESSURES; EMISSIONS;
D O I
10.3390/s24206509
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thousands of particle number (PN) counters have been introduced to the European market, following the implementation of PN tests during the periodic technical inspection (PTI) of diesel vehicles equipped with particulate filters. Expanding the PN-PTI test to gasoline vehicles may face several challenges due to the different exhaust aerosol characteristics. In this study, two PN-PTI instruments, type-examined for diesel vehicles, measured fifteen petrol passenger cars with different test protocols: low and high idling, with or without additional load, and sharp accelerations. The instruments, one based on diffusion charging and the other on condensation particle counting, demonstrated good linearity compared to the reference instrumentation with R-squared values of 0.93 and 0.92, respectively. However, in a considerable number of tests, they registered higher particle concentrations due to the presence of high concentrations below their theoretical 23 nm cut-off size. The evaluation of the different test protocols showed that gasoline direct injection engine vehicles without particulate filters (GPFs) generally emitted an order of magnitude or higher PN compared to those with GPFs. However, high variations in concentration levels were observed for each vehicle. Port-fuel injection vehicles without GPFs mostly emitted PN concentrations near the lower detection limit of the PN-PTI instruments.
引用
收藏
页数:15
相关论文
共 4 条
  • [1] Laboratory measurements with solid particle number instruments designed for periodic technical inspection (PTI) of vehicles
    Melas, Anastasios
    Vasilatou, Konstantina
    Suarez-Bertoa, Ricardo
    Giechaskiel, Barouch
    MEASUREMENT, 2023, 215
  • [2] Evaluation of Measurement Procedures for Solid Particle Number (SPN) Measurements during the Periodic Technical Inspection (PTI) of Vehicles
    Melas, Anastasios
    Selleri, Tommaso
    Suarez-Bertoa, Ricardo
    Giechaskiel, Barouch
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (13)
  • [3] Effects of the test aerosol on the performance of periodic technical inspection particle counters
    Vasilatou, Konstantina
    Wa, Christian
    Auderset, Kevin
    Burtscher, Heinz
    Hammer, Tobias
    Giechaskiel, Barouch
    Melas, Anastasios
    JOURNAL OF AEROSOL SCIENCE, 2023, 172
  • [4] Evaluation of Solid Particle Number Sensors for Periodic Technical Inspection of Passenger Cars
    Melas, Anastasios
    Selleri, Tommaso
    Suarez-Bertoa, Ricardo
    Giechaskiel, Barouch
    SENSORS, 2021, 21 (24)