Sensitive and rapid determination of the iodine/calcium ratio in carbonate rock samples by ICP-MS based on solution cathode glow discharge sampling

被引:0
作者
Wang, Xuan [1 ]
Liu, Xing [1 ]
Jin, Lanlan [1 ]
Zhu, Zhenli [1 ,2 ]
Dong, Junhang [1 ]
Xing, Pengju [1 ]
Chen, Linjie [1 ]
Geng, Yuanhui [2 ]
Zhang, Jingwen [1 ]
Tong, Hao [2 ]
Zheng, Hongtao [2 ]
Zhang, Min [3 ]
Hu, Shenghong [1 ]
机构
[1] China Univ Geosci, State Key Lab Biogeol & Environm Geol, Wuhan 430074, Peoples R China
[2] China Univ Geosci, Fac Mat Sci & Chem, Wuhan 430074, Peoples R China
[3] China Univ Geosci, Off Lab & Equipment Management, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
ATOMIC-EMISSION-SPECTROMETRY; VAPOR GENERATION; OCEAN REDOX; IODINE; PLASMA; SPECIATION; OXIDATION; CALCIUM; MERCURY; PROXY;
D O I
10.1039/d4ja00264d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The iodine-to-calcium ratio (I/Ca) in carbonate rocks has been extensively used to indicate marine oxidation states. However, the low-iodine and high-calcium characteristics of carbonate samples pose challenges in achieving rapid and accurate determination of I/Ca. In this study, we have developed a solution cathode glow discharge (SCGD) sampling technique coupled with inductively coupled plasma mass spectrometry (ICP-MS) for highly sensitive and accurate determination of I/Ca in low-iodine carbonate samples. The proposed method takes full advantage of the high-efficiency vapor generation of iodine and the inefficient introduction of calcium by SCGD, thereby significantly enhancing the sensitivity for iodine measurement and reducing matrix interference. In addition, it enables the simultaneous determination of I and Ca even in high-calcium samples. Compared to conventional pneumatic nebulization sampling, the SCGD sampling method demonstrated a 100-fold sensitivity improvement for iodine determination, while Ca sensitivity was reduced by a factor of 70. The effect of operating parameters and reaction conditions on the signal intensities was investigated. Under optimized conditions, the iodine detection limit was as low as 0.9 pg g-1 for carbonate samples. Finally, the validity of the method was verified through the analysis of standard reference samples, actual carbonate rocks, and simulated samples. The results conclusively demonstrate that our developed method offers a simple, sensitive, and rapid approach for accurately measuring the I/Ca ratio in carbonate rocks, thereby facilitating broader application of the I/Ca indicator.
引用
收藏
页码:3198 / 3206
页数:9
相关论文
共 50 条
[1]   Ultrasensitive determination of mercury by ICP-OES coupled with a vapor generation approach based on solution cathode glow discharge [J].
Cai, Zhaoqing ;
Zou, Huijun ;
Chen, Yirui ;
Wang, Zheng .
CHINESE CHEMICAL LETTERS, 2022, 33 (05) :2692-2696
[2]   Effect of single aerosol droplets on plasma impedance in the inductively coupled plasma [J].
Chan, George C. -Y. ;
Zhu, Zhenli ;
Hieftje, Gary M. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 76 :87-95
[3]   Determination of Trace Elemental Composition of CaCO3: Application to Mass Limited Abiogenic and Biogenic Carbonates [J].
Chanakya, I. V. Satya ;
Misra, Sambuddha .
GEOCHEMISTRY GEOPHYSICS GEOSYSTEMS, 2024, 25 (02)
[4]   Iodine stability as a function of pH and its implications for simultaneous multi-element ICP-MS analysis of marine carbonates for paleoenvironmental reconstructions [J].
Cook, Madelyn K. ;
Dial, Angela R. ;
Hendy, Ingrid L. .
MARINE CHEMISTRY, 2022, 245
[5]   Mineralogy-based stepwise dissolution of dolomitic limestone reveals high iodine content in water-column precipitated calcite and well - oxygenated shallow seawater during the-1.57 Ga oxygenation event [J].
Fang, Hao ;
Tang, Dongjie ;
Zhou, Limin ;
Jiang, Ganqing ;
Shi, Xiaoying ;
Liang, Liyuan ;
Zhou, Xiqiang ;
Sun, Longfei ;
Xie, Baozeng .
CHEMICAL GEOLOGY, 2024, 654
[6]   Non-zero I/(Ca plus Mg) recorded in Archean and Paleoproterozoic shallow marine Ca-carbonate sediments [J].
Fang, Hao ;
Fralick, Philip ;
Ramsay, Brittany ;
Tang, Dongjie ;
Riding, Robert .
PRECAMBRIAN RESEARCH, 2024, 405
[7]   Early Mesoproterozoic Ca-carbonate precipitates record fluctuations in shallow marine oxygenation [J].
Fang, Hao ;
Tang, Dongjie ;
Shi, Xiaoying ;
Zhou, Limin ;
Zhou, Xiqiang ;
Wu, Mengting ;
Song, Huyue ;
Riding, Robert .
PRECAMBRIAN RESEARCH, 2022, 373
[8]   Determination of halogens in coal after digestion using the microwave-induced combustion technique [J].
Flores, Erico M. M. ;
Mesko, Marcia F. ;
Moraes, Diogo P. ;
Pereira, Juliana S. F. ;
Mello, Paola A. ;
Barin, Juliano S. ;
Knapp, Guenter .
ANALYTICAL CHEMISTRY, 2008, 80 (06) :1865-1870
[9]   Challenges and trends for halogen determination by inductively coupled plasma mass spectrometry: A review [J].
Flores, Erico M. M. ;
Mello, Paola A. ;
Krzyzaniak, Sindy R. ;
Cauduro, Vitoria H. ;
Picoloto, Rochele S. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34
[10]  
Gorska M, 2023, ANAL METHODS-UK, V15, P1775, DOI [10.1039/d3ay00092c, 10.1039/D3AY00092C]