Operational Analysis of OCR Due to Application of SFCL in Power Distribution System with Distributed Generations

被引:0
作者
Choi, Seung-Su [1 ]
Park, Min-Ki [1 ]
Kim, Su-Hyeon [1 ]
Kim, Hak-Goon [1 ]
Lim, Sung-Hun [1 ]
机构
[1] Dept. of Electrical Engineering, Soongsil University
关键词
Distributed Generation (DG); Malfunction; Overcurrent Relay (OCR); Protective Coordination; Superconducting Fault Current Limiter (SFCL);
D O I
10.5370/KIEE.2024.73.11.1930
中图分类号
学科分类号
摘要
The application of distributed generations (DGs) is increasing. Because renewable energy is eco-friendly and has low carbon emissions interest on renewable energy based DGs is growing. However, as the number of DGs increases, the fault current magnitude in the system can either increase or decrease during faults. These changes can result in malfunctions or failure of overcurrent relays (OCRs), potentially leading to a large blackout. Research on superconducting fault current limiter (SFCL) to limit fault currents has been conducted, but applying SFCLs in distribution systems with DGs can complicate protective coordination among relays. In this paper, cases of malfunction and failure of OCRs due to the connection of distributed power sources were analyzed, and method to improve the protective coordination of OCRs using SFCLs were proposed. Copyright © The Korean Institute of Electrical Engineers.
引用
收藏
页码:1930 / 1938
页数:8
相关论文
共 18 条
  • [1] Faisal M., Et al., Review of energy storage system technologies in microgrid applications: Issues and challenges, IEEE Access, 6, pp. 35143-35164, (2018)
  • [2] Brenna M., Et al., Integration and optimization of renewables and storages for rural electrification, Sustainability, 8, 10, (2016)
  • [3] Kim J. -S., Et al., Development of protection method for power system interconnected with distributed generation using distance relay, Journal of Electrical Engineering & Technology, 13, 6, pp. 2196-2202, (2018)
  • [4] Jennett K., Et al., Analysis of the sympathetic tripping problem for networks with high penetrations of Distributed Generation, 2011 International Conference on Advanced Power System Automation and Protection, pp. 384-389, (2011)
  • [5] Cheung H., Et al., Network-based Adaptive Protection Strategy for Feeders with Distributed Generations, 2007 IEEE Canada Electrical Power Conference, pp. 514-519, (2007)
  • [6] Moon W. -S., Et al., A Study on the Application of a Superconducting Fault Current Limiter for Energy Storage Protection in a Power Distribution System, IEEE Transactions on Applied Superconductivity, 23, 3, pp. 5603404-5603404, (2013)
  • [7] Lim S. -H., Study on current limiting characteristics of SFCL with two trigger current levels, Physica C: Superconductivity and its Applications, 470, 20, pp. 1631-1635, (2010)
  • [8] Lim S. -H., Analysis on Current Limiting and Recovery Characteristics of a SFCL using a Trigger of Superconducting Element, Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, The Korean Institute of Illuminating and Electrical Installation Engineers, 24, 1, pp. 112-116, (2010)
  • [9] Lim S. -T., Lim S. -H., Analysis on operational improvement of OCR using voltage component in a power distribution system for application of SFCL, Journal of Electrical Engineering & Technology, 14, pp. 1027-1033, (2019)
  • [10] Lim S. -T., Lim S. -H., Analysis on protective coordination between over-current relays with voltage component in a power distribution system with SFCL, IEEE Transactions on Applied Superconductivity, 30, 4, pp. 1-6, (2020)