Seismic Retrofit Assessment of a School Building through Operational Modal Analysis and f.e. Modeling

被引:6
|
作者
Gara F. [1 ]
Carbonari S. [2 ]
Roia D. [3 ]
Balducci A. [1 ]
Dezi L. [1 ]
机构
[1] Dept. of Construction, Civil Engineering and Architecture, Università Politecnica Delle Marche, Via Brecce Bianche, Ancona
[2] Dept. of Economy, Science and Law, Univ. of San Marino, Via Consiglio dei Sessanta, Dogana
[3] SeiTec Seismotechnologies S.r.l., Via di Passo Varano 306, Ancona
来源
Journal of Structural Engineering (United States) | 2021年 / 147卷 / 01期
关键词
Ambient vibration test; Building dynamic identification; Finite-element model upgrading; Operational modal analysis; Reinforced concrete frame building retrofitting; Steel dissipative towers;
D O I
10.1061/(ASCE)ST.1943-541X.0002865
中图分类号
学科分类号
摘要
The paper deals with the dynamic characterization of a reinforced concrete (RC) frame school building in central Italy before and after the seismic retrofitting, obtained by coupling the building with an innovative patented seismic dissipative protection system. Before the retrofit, ambient vibration tests were performed to evaluate frequencies and mode shapes for developing finite-element (f.e.) models describing the school dynamic behavior in operational conditions. Several finite-element models with increasing level of detail are presented, from the bare frame model, based on the assumptions and simplifications usually adopted for design purposes, to an upgraded model taking account of secondary and nonstructural elements (e.g., internal and external walls, screeds, roofing, floor tiles, and plasters) as well as the interaction between structure and retaining walls. The latter was used to develop the design model of the seismic retrofitting system, which aims to assure the immediate occupancy of the building in the case of severe earthquakes limiting damage to nonstructural components. Tests were repeated after the retrofit to check consistency with numerical design predictions. Comparisons between experimental and numerical modal parameters are shown discussing the usefulness of ambient vibration tests. © 2020 American Society of Civil Engineers.
引用
收藏
相关论文
共 4 条
  • [1] Seismic Retrofit Assessment of a School Building through Operational Modal Analysis and f.e. Modeling
    Gara, Fabrizio
    Carbonari, Sandro
    Roia, Davide
    Balducci, Alessandro
    Dezi, Luigino
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (01)
  • [2] OPERATIONAL MODAL ANALYSIS APPLIED TO A SEISMIC BEHAVIOUR ASSESSMENT OF LONG VIADUCTS
    Fernandez, J.
    Hermanns, L.
    Fraile, A.
    Ahijado, M.
    Hernandez, A.
    Simon-Talero, J. M.
    6TH IOMAC: INTERNATIONAL OPERATIONAL MODAL ANALYSIS CONFERENCE PROCEEDINGS, 2015, : 129 - 137
  • [3] Assessment of Seismic Retrofitting Interventions of a Masonry Palace Using Operational Modal Analysis
    Aloisio, Angelo
    Di Pasquale, Alessandro
    Alaggio, Rocco
    Fragiacomo, Massimo
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2022, 16 (05) : 692 - 704
  • [4] Evaluation of Existing Damage Patterns and Seismic Assessment of Historical Davutpasa Barracks via Operational-Modal Analysis
    Gani, Emre
    Erdogan, Yildirim Serhat
    Kocak, Ali
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2020, 34 (04)