Analysis of steam ejector performance with corrugated nozzle

被引:0
|
作者
Qu, Xiaohang [1 ]
Tian, Maocheng [1 ]
Luo, Lincong [1 ]
Leng, Xueli [1 ]
机构
[1] School of Energy and Power Engineering, Shandong University, Jinan , 250061, Shandong Province
来源
Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering | 2014年 / 34卷 / 35期
关键词
Corrugated nozzle; Ejector; Entrainment ratio; Vortex;
D O I
10.13334/j.0258-8013.pcsee.2014.35.001
中图分类号
学科分类号
摘要
Performance of a steam ejector mounted with corrugation shaped primary nozzle was analyzed, after a three-dimensional simulation model was built and verified with experimental results of the ejector with an ordinary nozzle. The effects of the number of corrugations (Cn), amplitude (h/D), ratio of the length covered by corrugation (l/L) and the angle twisted of the corrugation (θ) on entrainment ratio (ER) and critical back pressure (CBP) were investigated. Analysis of the vortex (stream-wise and span-wise) formed in the mixing chamber showed that the vortex with larger strength and a longer life span results in higher ER. As the secondary flow rate increases and the turbulence gets intense, the loss of the mechanical energy increases, leading to the decrease of CBP. While the span-wise vortex contacts too early with the wall of the mixing chamber, the vortex will decay rapidly and both the ER and CBP will decrease. In the range covered by this paper, compared with the nozzle without corrugation, ER can increase by up to 13.9% and the corresponding CBP decreases by 5.1%. © 2014 Chin. Soc. for Elec. Eng.
引用
收藏
页码:6255 / 6262
页数:7
相关论文
共 24 条
  • [1] Shah A., Chughtai I.R., Inayat M.H., Experimental study of the characteristics of steam jet pump and effect of mixing section length on direct-contact condensation, International Journal of Heat and Mass Transfer, 58, 1-2, pp. 62-69, (2013)
  • [2] Narabayashi T., Mizumachi W., Mori M., Study on two phase flow dynamics in steam injectors, Nuclear Engineering and Design, 175, 1-2, pp. 147-156, (1997)
  • [3] Varga S., Oliveira A.C., Diaconu B., Influence of geometrical factors on steam ejector performance-A numerical assessment, International Journal of Refrigeration, 32, 7, pp. 1694-1701, (2009)
  • [4] Zheng B., Weng Y., Gu W., Et al., Analysis of a combined power and ejector refrigeration cycle for low temperature heat sources, Proceedings of the CSEE, 28, 29, pp. 16-21, (2008)
  • [5] Wang F., Lv H., Feng W., Et al., Performance of two-phase ejector in compression/ejecion refrigeration cycle, CIESC Journal, 63, 10, pp. 3094-3100, (2012)
  • [6] Zhou H., Meng H., Tong M., Et al., Experiment on performance of adjustable ejecting-mixing low-pressure heater, Proceedings of the CSEE, 30, 14, pp. 26-30, (2010)
  • [7] Cai Q., Tong M., Shen B., Et al., Experiment on performance of new type ejecting heater, Drainage and Irrigation Machinery, 27, 4, pp. 261-264, (2009)
  • [8] Liu J., Yan J., Xing Q., Et al., A theoretical research on supersonic heating technology applied for the L.P. heater system in a power plant, Proceedings of the CSEE, 23, 12, pp. 175-178, (2003)
  • [9] Tong M., Bai X., Cai Q., Et al., Experimental research on performance of jetting-mixing low pressure heater of single-stage and double-stage injector, Proceedings of the CSEE, 30, 5, pp. 83-86, (2010)
  • [10] Sriveerakul T., Aphornratana S., Chunnanond K., Performance prediction of steam ejector using computational fluid dynamics: Part 1.Validation of the CFD results, International Journal of Thermal Sciences, 46, 8, pp. 812-822, (2007)