Quality assessment and lifetime prediction of base metal electrode multilayer ceramic capacitors: Challenges and opportunities

被引:0
作者
Yousefian P. [1 ]
Randall C.A. [1 ]
机构
[1] Materials Research Institute, Department of Materials Science and Engineering, Center for Dielectrics and Piezoelectrics, The Pennsylvania State University, University Park, 16802, PA
来源
Power Electronic Devices and Components | 2023年 / 6卷
基金
美国国家科学基金会;
关键词
Burn-in; Failure analysis; Machine learning; MLCC; MTTF; Multilayer ceramic capacitors; Reliability; TSDC;
D O I
10.1016/j.pedc.2023.100045
中图分类号
学科分类号
摘要
Base metal electrode (BME) multilayer ceramic capacitors (MLCCs) are widely used in aerospace, medical, military, and communication applications, emphasizing the need for high reliability. The ongoing advancements in BaTiO3-based MLCC technology have facilitated further miniaturization and improved capacitive volumetric density for both low and high voltage devices. However, concerns persist regarding infant mortality failures and long-term reliability under higher fields and temperatures. To address these concerns, a comprehensive understanding of the mechanisms underlying insulation resistance degradation is crucial. Furthermore, there is a need to develop effective screening procedures during MLCC production and improve the accuracy of mean time to failure (MTTF) predictions. This article reviews our findings on the effect of the burn-in test, a common quality control process, on the dynamics of oxygen vacancies within BME MLCCs. These findings reveal the burn-in test has a negative impact on the lifetime and reliability of BME MLCCS. Moreover, the limitations of existing lifetime prediction models for BME MLCCs are discussed, emphasizing the need for improved MTTF predictions by employing a physics-based machine learning model to overcome the existing models’ limitations. The article also discusses the new physical-based machine learning model that has been developed. While data limitations remain a challenge, the physics-based machine learning approach offers promising results for MTTF prediction in MLCCs, contributing to improved lifetime predictions. Furthermore, the article acknowledges the limitations of relying solely on MTTF to predict MLCCs’ lifetime and emphasizes the importance of developing comprehensive prediction models that predict the entire distribution of failures. © 2023
引用
收藏
相关论文
共 56 条
  • [1] Akkopru-Akgun B., Marincel D.M., Tsuji K., Bayer T.J.M., Randall C.A., Lanagan M.T., Et al., Thermally stimulated depolarization current measurements on degraded lead zirconate titanate films, J. Am. Ceram. Soc., 104, 10, pp. 5270-5280, (2021)
  • [2] Baiatu T., Waser R., Hardtl K.-H., dc electrical degradation of perovskite-type titanates: III, a model of the mechanism, J. Am. Ceram. Soc., 73, 6, pp. 1663-1673, (1990)
  • [3] Braunlich P., Thermally stimulated relaxation in solids, (1979)
  • [4] Buessem W.R., Prokopowicz T.I., Electrode and materials problems in ceramic capacitors, Ferroelectrics, 10, 1, pp. 225-230, (1976)
  • [5] Chazono H., Kishi H., pp. 5624-5629, (2001)
  • [6] Confer R., Canner J., Trostle T., Kurtz S., 41st Electronic Components & Technology Conference, pp. 320-322, (1991)
  • [7] Cooper M., Observations on component infant mortality and burn-in effectiveness, IEEE Trans. Compon. Packag. Technol., 31, 4, pp. 914-916, (2008)
  • [8] (2017)
  • [9] English A.T., Melliar-Smith C.M., Reliability and failure mechanisms of electronic materials, Annu. Rev. Mater. Sci., 8, 1, pp. 459-495, (1978)
  • [10] Gaonkar A., Patil R.B., Kyeong S., Das D., Pecht M.G., An assessment of validity of the bathtub model hazard rate trends in electronics, IEEE Access : Pract. Innov. Open Solut., 9, pp. 10282-10290, (2021)