A simulation study of plasmonic substrate for in-process measurement of refractive index in nano-stereolithography

被引:0
|
作者
Michihata M. [1 ]
Kong D. [2 ]
Takamasu K. [3 ]
Takahashi S. [1 ]
机构
[1] Research Center for Advanced Science and Technology, The University of Tokyo, 4-6-1 Komaba, Meguro, Tokyo
[2] Department of Advanced Interdisciplinary Studies, The University of Tokyo, 4-6-1 Komaba, Meguro-Ku, Tokyo
[3] Department of Precision Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo
来源
Michihata, Masaki (michihata@nanolab.t.u-tokyo.ac.jp) | 1600年 / Fuji Technology Press卷 / 11期
基金
日本学术振兴会;
关键词
In-process measurement; PLZT; Refractive index; Stereolithography; Surface plasmon resonance;
D O I
10.20965/ijat.2017.p0772
中图分类号
学科分类号
摘要
Functional surfaces are in demand for recent valueadded products. Stereolithography based on evanescent light has been proposed as a technique to fabricate surface nanostructures, but some fabrication error sources must be addressed. In-process measurement is an essential solution to improve the fabrication performance. For in-process measurement in stereolithography, the refractive index of resin is an inherent parameter for product and condition monitoring. This study proposes the in-processmeasurement of the refractive index of resin based on surface plasmon resonance (SPR). The optical phase response at SPR is highly sensitive to changes in the refractive index of resin but has a narrow sensing range. Therefore, we propose a substrate with a tunable sensing range using lanthanum-modified lead zirconate titanate (PLZT). The structural design was considered using numerical simulation. The SPR conditions were calculated with regard to thickness combinations of PLZT and metal (Ag) films. Depending on these combinations, a sensing range can be tuned on the order of 10-3 to 10-4 RIU with a sensitivity of 106 rad/RIU. However, to realize these performances, the manufacturing accuracy of Ag thin films must be better than 0.1 nm. © 2017, Fuji Technology Press. All rights reserved.
引用
收藏
页码:772 / 780
页数:8
相关论文
共 50 条
  • [1] Development of an in-process confocal positioning system for nano-stereolithography using evanescent light
    Kajihara, Yusuke
    Takeuchi, Toru
    Takahashi, Satoru
    Takamasu, Kiyoshi
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2008, 9 (03): : 51 - 54
  • [2] In-Process Measurement of Thickness of Cured Resin in Evanescent-Wave-Based Nano-stereolithography Using Critical Angle Reflection
    Kong D.
    Michihata M.
    Takamasu K.
    Takahashi S.
    Nanomanufacturing and Metrology, 2018, 1 (02) : 112 - 124
  • [3] In-process Measurement of Gradient Boundary of Resin in Evanescent-wave-based Nano-stereolithography using Reflection Interference near Critical Angle
    Kong, Deqing
    Michihata, Masaki
    Takamasu, Kiyoshi
    Takahashi, Satoshi
    JOURNAL OF PHOTOPOLYMER SCIENCE AND TECHNOLOGY, 2018, 31 (03) : 441 - 446
  • [4] In-process measurement for cure depth control of nano stereolithography using evanescent light
    Takahashi, S.
    Kong, D.
    Michihata, M.
    Takamasu, K.
    CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2019, 68 (01) : 527 - 530
  • [5] Simulation of the refractive index sensitivity of coupled plasmonic nanostructures
    Bonyar, A.
    PROCEEDINGS OF THE 30TH ANNIVERSARY EUROSENSORS CONFERENCE - EUROSENSORS 2016, 2016, 168 : 962 - 965
  • [6] Proposal of in-process measurement for micro-stereolithography using surface plasmon resonance
    Michihata, Masaki
    Takamasu, Kiyoshi
    Takahashi, Satoru
    LASER ASSISTED NET SHAPE ENGINEERING 9 INTERNATIONAL CONFERENCE ON PHOTONIC TECHNOLOGIES PROCEEDINGS OF THE LANE 2016, 2016, 83 : 964 - 970
  • [7] Hybrid plasmonic biosensor for simultaneous measurement of both thickness and refractive index
    Ma, Youqiao
    Farrell, Gerald
    Semenova, Yuliya
    Chan, Hau Ping
    Wu, Qiang
    INFRARED PHYSICS & TECHNOLOGY, 2013, 60 : 134 - 136
  • [8] Plasmonic nano bow-tie arrays with enhanced LSPR refractive index sensing
    Khoshdel, Vahid
    Shokooh-Saremi, Mehrdad
    MICRO & NANO LETTERS, 2019, 14 (05): : 566 - 571
  • [9] THz Measurement of Refractive Index and Thickness of Ceramic Coating on a Metal Substrate
    Fukuchi, T.
    Fuse, N.
    Mizuno, M.
    Fukunaga, K.
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2013,
  • [10] FACTORS AFFECTING THE MEASUREMENT OF ELECTRICAL-CONDUCTIVITY, SPECIFIC CONDUCTIVITY, AND REFRACTIVE-INDEX IN IN-PROCESS QUALITY-CONTROL OF INFUSION SOLUTIONS
    GRUNDMANN, W
    GRUNDMANN, E
    PHARMAZEUTISCHE PRAXIS, 1979, 34 (03): : 130 - 131