Thermal-hydraulic characteristics of an earth air heat exchanger: An experimental analysis

被引:0
|
作者
El-Said, Emad M. S. [1 ,2 ]
机构
[1] Damietta Univ, Fac Engn, Mech Power Engn Dept, Dumyat 34511, Egypt
[2] Future Higher Inst Engn & Technol, Mansoura, Egypt
关键词
Earth air heat exchanger; Geometric configurations; Thermal-hydraluic analysis; PERFORMANCE; SYSTEM; ENERGY;
D O I
10.1016/j.energy.2024.133766
中图分类号
O414.1 [热力学];
学科分类号
摘要
The pipe layout design has a great effect on the thermal-hydraulic characteristics of earth air heat exchanger (EAHE) systems. So, in the current study proposed four new buried pipe design configurations; low to high to low, high to low to high, spiral, and circular, in addition to the straight or uniform for comparison. These five configurations are tested and analyzed experimentally depending on the thermo-hydraulic performance for summer cooling requirements with variation of Re in the range of 18041-40843. The results show that changing the uniform design of the EAHE with fixed pipe length enhances both the heat transfer process and pressure loss values. At the same operating conditions, the circular design has the best performance compared to the other ones. For all pipe shapes, the cooling effect increases with the increase of air Re. The thermal-hydraulic performance of the circular design pipe is higher than that of the other pipe designs. The highest coefficient of performance (COP) average values that can be obtained at Re = 18041 is 3.05 for circular shape and enhances by 48.08 % compared to uniform shape. The effectiveness of EAHE with circular shape is improved by about 3.52 % compared to uniform shape at Re = 18041. Spiral design is optimum design based on the Nu value which reaches about 48 with enhancement 12.56 % and 0.34 % compared to uniform and circular shapes respectively, at Re = 40843. The hydrothermal performance factor is highest in the case of circular shape with value about 21.9 at Re = 21257. By increasing Re, the drawbacks of the increasing in the total entropy generation are reflected negatively on the exergy efficiency. The specific cost of the circular shape at Re = 40843 is the optimum value by about 0.7 $/W. Spiral and circular shapes have a decrease of CO2 emissions less than uniform shape by percentage varied from 2.93 % to 13.84 % for decrease in the Re from 21257 to 40843. It is concluded that using EAHE with four new shapes is highly efficient in increasing cooling capacity and energy consumption in buildings.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Investigation of the effect of different materials on thermal performance of earth - air heat exchanger (EAHX)
    Bulut, Husamettin
    Demirtas, Yunus
    Beyazit, Nesrin Ilgin
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2018, 33 (04): : 1505 - 1516
  • [42] Numerical thermal-hydraulic analysis and multiobjective design optimization of a printed circuit heat exchanger with airfoil overlap fin channels
    Kuo, Geng-Chun
    Xie, Jun-Yu
    Chueh, Chih-Che
    ENGINEERING REPORTS, 2024, 6 (02)
  • [43] Experimental study of an earth to air heat exchanger (EAHE) for warm humid climatic conditions
    Diaz-Hernandez, H. P.
    Macias-Melo, E., V
    Aguilar-Castro, K. M.
    Hernandez-Perez, I
    Xaman, J.
    Serrano-Arellano, J.
    Lopez-Manrique, L. M.
    GEOTHERMICS, 2020, 84
  • [44] Enhancing the performance of an earth air heat exchanger with novel pipe configurations
    El-Said, Emad M. S.
    Sharaf, Maisa A.
    Aljabr, Ahmad
    Marzouk, S. A.
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2024, 110
  • [45] An experimental investigation on the passive ventilation and cooling performance of an integrated solar chimney and earth-air heat exchanger
    Li, Yongcai
    Long, Tianhe
    Bai, Xi
    Wang, Linfeng
    Li, Wuyan
    Liu, Shuli
    Lu, Jun
    Cheng, Yong
    Ye, Kai
    Huang, Sheng
    RENEWABLE ENERGY, 2021, 175 : 486 - 500
  • [46] Thermal Analysis of a Generic Earth-to-Air Heat Exchanger Coupled with a Room during the Summer Season in a Desert Climate
    Maytorena, V. M.
    Hinojosa, J. F.
    JOURNAL OF ENERGY ENGINEERING, 2022, 148 (02)
  • [47] Airside thermal-hydraulic characteristics for tube bank heat exchangers used to cool compressor bleed air in an aero engine
    Gu, L. D.
    Min, J. C.
    APPLIED THERMAL ENGINEERING, 2018, 141 : 939 - 947
  • [48] Two-stage thermal-hydraulic optimization for Pillow Plate Heat Exchanger with recirculation zone parameterization
    Tong, Zheming
    Yang, Qi
    Tong, Shuiguang
    Chen, Xin
    APPLIED THERMAL ENGINEERING, 2022, 215
  • [49] Thermal-hydraulic performance analysis of printed circuit heat exchanger precooler in the Brayton cycle for supercritical CO2 waste heat recovery
    Liu, Bohan
    Lu, Mingjian
    Shui, Bo
    Sun, Yuwei
    Wei, Wei
    APPLIED ENERGY, 2022, 305
  • [50] Thermal potential of a geothermal earth-to-air heat exchanger in six climatic conditions of Mexico
    Rodriguez-Vazquez, M.
    Xaman, J.
    Chavez, Y.
    Hernandez-Perez, I.
    Sima, E.
    MECHANICS & INDUSTRY, 2020, 21 (03)