Thermal-hydraulic characteristics of an earth air heat exchanger: An experimental analysis

被引:0
|
作者
El-Said, Emad M. S. [1 ,2 ]
机构
[1] Damietta Univ, Fac Engn, Mech Power Engn Dept, Dumyat 34511, Egypt
[2] Future Higher Inst Engn & Technol, Mansoura, Egypt
关键词
Earth air heat exchanger; Geometric configurations; Thermal-hydraluic analysis; PERFORMANCE; SYSTEM; ENERGY;
D O I
10.1016/j.energy.2024.133766
中图分类号
O414.1 [热力学];
学科分类号
摘要
The pipe layout design has a great effect on the thermal-hydraulic characteristics of earth air heat exchanger (EAHE) systems. So, in the current study proposed four new buried pipe design configurations; low to high to low, high to low to high, spiral, and circular, in addition to the straight or uniform for comparison. These five configurations are tested and analyzed experimentally depending on the thermo-hydraulic performance for summer cooling requirements with variation of Re in the range of 18041-40843. The results show that changing the uniform design of the EAHE with fixed pipe length enhances both the heat transfer process and pressure loss values. At the same operating conditions, the circular design has the best performance compared to the other ones. For all pipe shapes, the cooling effect increases with the increase of air Re. The thermal-hydraulic performance of the circular design pipe is higher than that of the other pipe designs. The highest coefficient of performance (COP) average values that can be obtained at Re = 18041 is 3.05 for circular shape and enhances by 48.08 % compared to uniform shape. The effectiveness of EAHE with circular shape is improved by about 3.52 % compared to uniform shape at Re = 18041. Spiral design is optimum design based on the Nu value which reaches about 48 with enhancement 12.56 % and 0.34 % compared to uniform and circular shapes respectively, at Re = 40843. The hydrothermal performance factor is highest in the case of circular shape with value about 21.9 at Re = 21257. By increasing Re, the drawbacks of the increasing in the total entropy generation are reflected negatively on the exergy efficiency. The specific cost of the circular shape at Re = 40843 is the optimum value by about 0.7 $/W. Spiral and circular shapes have a decrease of CO2 emissions less than uniform shape by percentage varied from 2.93 % to 13.84 % for decrease in the Re from 21257 to 40843. It is concluded that using EAHE with four new shapes is highly efficient in increasing cooling capacity and energy consumption in buildings.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Numerical study of earth-to-air heat exchanger: The effect of thermal insulation
    Xaman, J.
    Hernandez-Perez, I.
    Arce, J.
    Alvarez, G.
    Ramirez-Davila, L.
    Noh-Pat, F.
    ENERGY AND BUILDINGS, 2014, 85 : 356 - 361
  • [32] Study on thermal-hydraulic characteristics of CO2-water printed circuit heat exchanger with different structural parameters
    Jin, Feng
    Chen, Deqi
    Hu, Lian
    Huang, Yanping
    Bu, Shanshan
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2022, 34
  • [33] Evaluation of optimal thermal-hydraulic characteristics ratio in microchannel heat exchangers
    Garyaev, A. B.
    Prun, O. E.
    Klimenko, A. V.
    THERMOPHYSICS AND AEROMECHANICS, 2015, 22 (06) : 723 - 732
  • [34] Experimental analysis and model verification of a new earth-to-air heat exchanger system
    Liu, Zhengxuan
    Roccamena, Letizia
    El Mankibi, Mohamed
    Yu, Zhun
    Yang, Tingting
    Sun, Ying
    Sun, Pengcheng
    Li, Shuisheng
    Zhang, Guoqiang
    2018 4TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGIES FOR DEVELOPING COUNTRIES (REDEC), 2018,
  • [35] Design and thermal-hydraulic evaluation of the finned-tube type sodium-to-air heat exchanger in sodium test facility
    Kim, Hyungmo
    Yoon, Jung
    Lee, Hyeong-Yeon
    Eoh, Jaehyuk
    Jeong, Ji-Young
    Lee, Jewhan
    NUCLEAR ENGINEERING AND DESIGN, 2020, 366
  • [36] Parametric Analysis on an Earth-to-Air Heat Exchanger Employed in an Air Conditioning System
    D'Agostino, Diana
    Esposito, Francesco
    Greco, Adriana
    Masselli, Claudia
    Minichiello, Francesco
    ENERGIES, 2020, 13 (11)
  • [37] Experimental evaluation of an earth-to-air heat exchanger and air source heat pump hybrid indoor air conditioning system
    Guo, Xin
    Wei, Haibin
    He, Xiao
    Du, Jinhui
    Yang, Dong
    ENERGY AND BUILDINGS, 2022, 256
  • [38] Experimental and numerical study of the sunspot's effect on the dynamic thermal behavior of a room equipped with an earth-air heat exchanger, in the heating season
    Maaden, Hafsa
    Menhoudj, Sayeh
    Mokhtari, Abderahmane Mejedoub
    Benzaama, Mohammed Hichem
    JOURNAL OF BUILDING ENGINEERING, 2023, 68
  • [39] Thermal-hydraulic characteristics of gasketed plate heat exchangers as a preheater for thermal desalination systems
    Jamil, Muhammad Ahmad
    Din, Zia Ud
    Goraya, Talha S.
    Yagoob, Haseeb
    Zubair, Syed M.
    ENERGY CONVERSION AND MANAGEMENT, 2020, 205
  • [40] Numerical investigation on thermal-hydraulic performance of variable cross section printed circuit heat exchanger
    Yuan, Ping
    Tian, Hua
    Wang, Xuan
    Zhang, Xuanang
    Zhang, Hongfei
    Liang, Xingyu
    Shu, Gequn
    Li, Zhuqing
    PHYSICS OF FLUIDS, 2024, 36 (04)