Thermal-hydraulic characteristics of an earth air heat exchanger: An experimental analysis

被引:0
|
作者
El-Said, Emad M. S. [1 ,2 ]
机构
[1] Damietta Univ, Fac Engn, Mech Power Engn Dept, Dumyat 34511, Egypt
[2] Future Higher Inst Engn & Technol, Mansoura, Egypt
关键词
Earth air heat exchanger; Geometric configurations; Thermal-hydraluic analysis; PERFORMANCE; SYSTEM; ENERGY;
D O I
10.1016/j.energy.2024.133766
中图分类号
O414.1 [热力学];
学科分类号
摘要
The pipe layout design has a great effect on the thermal-hydraulic characteristics of earth air heat exchanger (EAHE) systems. So, in the current study proposed four new buried pipe design configurations; low to high to low, high to low to high, spiral, and circular, in addition to the straight or uniform for comparison. These five configurations are tested and analyzed experimentally depending on the thermo-hydraulic performance for summer cooling requirements with variation of Re in the range of 18041-40843. The results show that changing the uniform design of the EAHE with fixed pipe length enhances both the heat transfer process and pressure loss values. At the same operating conditions, the circular design has the best performance compared to the other ones. For all pipe shapes, the cooling effect increases with the increase of air Re. The thermal-hydraulic performance of the circular design pipe is higher than that of the other pipe designs. The highest coefficient of performance (COP) average values that can be obtained at Re = 18041 is 3.05 for circular shape and enhances by 48.08 % compared to uniform shape. The effectiveness of EAHE with circular shape is improved by about 3.52 % compared to uniform shape at Re = 18041. Spiral design is optimum design based on the Nu value which reaches about 48 with enhancement 12.56 % and 0.34 % compared to uniform and circular shapes respectively, at Re = 40843. The hydrothermal performance factor is highest in the case of circular shape with value about 21.9 at Re = 21257. By increasing Re, the drawbacks of the increasing in the total entropy generation are reflected negatively on the exergy efficiency. The specific cost of the circular shape at Re = 40843 is the optimum value by about 0.7 $/W. Spiral and circular shapes have a decrease of CO2 emissions less than uniform shape by percentage varied from 2.93 % to 13.84 % for decrease in the Re from 21257 to 40843. It is concluded that using EAHE with four new shapes is highly efficient in increasing cooling capacity and energy consumption in buildings.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A Numerical Investigation of Thermal Performance of Earth-Air Heat Exchanger
    Tasdelen, F.
    Dagtekin, I.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2019, 44 (02) : 1151 - 1163
  • [22] Thermal-Hydraulic Characteristics of Helical Baffle Shell-and-Tube Heat Exchangers
    Abdelkader, Bassel A.
    Jamil, Muhammad Ahmad
    Zubair, Syed M.
    HEAT TRANSFER ENGINEERING, 2020, 41 (13) : 1143 - 1155
  • [23] Experimental study on the characteristics of radiation floor cooling system based on an earth-air heat exchanger
    Yang, Jiaming
    Song, Wei
    Zhang, Houan
    Wang, Jing
    Dong, Jiankai
    ENERGY AND BUILDINGS, 2023, 296
  • [24] Annual thermal performance of greenhouse with an earth-air heat exchanger: An experimental validation
    Tiwari, G. N.
    Akhtar, M. A.
    Shukla, Ashish
    Khan, M. Emran
    RENEWABLE ENERGY, 2006, 31 (15) : 2432 - 2446
  • [25] Analysis of an earth-to-air heat exchanger for enhanced residential thermal comfort
    Dewangan, Chandraprakash
    Shukla, Anuj Kumar
    Salhotra, Rahul
    Dewan, Anupam
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2024, 43 (03)
  • [26] Experimental and numerical investigations of the thermal-hydraulic characteristics of novel micropin-fin heat sinks
    Xu, Yu
    Li, Ling
    Wang, Jiale
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 209
  • [27] Experimental investigation of the thermal-hydraulic characteristics of liquid cooling heat sinks with novel pin fins
    Wang, Jiale
    Qi, Shaohuan
    Xu, Zhaohao
    Xu, Yu
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 55
  • [28] Parametric simulation and experimental analysis of earth air heat exchanger with solar air heating duct
    Jakhar, Sanjeev
    Misra, Rohit
    Soni, M. S.
    Gakkhar, Nikhil
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2016, 19 (02): : 1059 - 1066
  • [29] Experimental Investigation of Flow Uniformity in a Bank-Type Earth-Air Heat Exchanger
    Goyal, Vaishali
    Asati, Arun Kumar
    Arora, Amit
    CHEMICAL ENGINEERING & TECHNOLOGY, 2023, 46 (08) : 1596 - 1604
  • [30] Parametric Study of Earth-Air Heat Exchanger based on Physical Experimentation
    Goyal, Vaishali
    Asati, Arun Kumar
    Garg, Rajeev Kumar
    Arora, Amit
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2023, 30 (02) : 232 - 239