Novel time-domain fault location algorithm by two-terminal currents

被引:0
|
作者
Gao, Shuping [1 ]
Song, Guobing [1 ]
Jiao, Zaibing [1 ]
Suonan, Jiale [1 ]
机构
[1] School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
10
引用
收藏
页码:101 / 105
相关论文
共 50 条
  • [41] Gaussian Process Regression-Based Predictive Fault Location Algorithm for Three-Terminal Lines Using Two-Terminal PMUs
    Badran, Osama
    Rizk, Mohammad E. M.
    Hu, Weihao
    Abulanwar, Sayed
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2024, 39 (04) : 5829 - 5853
  • [42] Real-Time Traveling-Wave-Based Fault Location Using Two-Terminal Unsynchronized Data
    Lopes, F. V.
    Silva, K. M.
    Costa, F. B.
    Neves, W. L. A.
    Fernandes, D., Jr.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1067 - 1076
  • [43] CHAOS TIME-DOMAIN REFLECTOMETRY FOR FAULT LOCATION ON LIVE WIRES
    Xu, Hang
    Li, Jingxia
    Liu, Li
    Wang, Bingjie
    Zhang, Jianguo
    Wang, Yuncai
    JOURNAL OF APPLIED ANALYSIS AND COMPUTATION, 2015, 5 (02): : 243 - 250
  • [44] A two-terminal fault location algorithm using asynchronous data based on phase characteristics for high voltage transmission line
    Chen, Xu
    Zhu, Yongli
    Guo, Xiaohong
    Gao, Yanfeng
    Zhao, Lei
    Zhao, Xuesong
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (22): : 152 - 156
  • [45] A two-terminal fault location method for gas switch prefire in linear transformer driver
    Wan, Zhenbo
    Ding, Weidong
    Sun, Fengju
    Jiang, Xiaofeng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (01):
  • [46] Asynchronous two-terminal fault location method of transmission line based on parameter modification
    Wang F.
    Mu K.
    Zhang J.
    Liu Y.
    Qian Y.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2018, 38 (08): : 95 - 101
  • [47] New method of fault location on double-circuit two-terminal transmission lines
    Mazon, AJ
    Minambres, JF
    Zorrozua, MA
    Zamora, I
    AlvarezIsasi, R
    ELECTRIC POWER SYSTEMS RESEARCH, 1995, 35 (03) : 213 - 219
  • [48] Two-terminal Asynchronous Fault Location Method for MMC-HVDC Transmission Line
    Yang Y.
    Huang C.
    Jiang Y.
    Liu P.
    Tang T.
    Huang, Chun (yellowpure@hotmail.com), 2018, Automation of Electric Power Systems Press (42): : 148 - 154
  • [49] A new two-terminal traveling wave fault location method based on wavelet transform
    Zheng, Zhou
    Lü, Yan-Ping
    Wang, Jie
    Wu, Fan
    Dianwang Jishu/Power System Technology, 2010, 34 (01): : 203 - 207
  • [50] A fault location algorithm for hybrid transmission line composed by high voltage cable and overhead line based on two-terminal information
    Yang, Jun
    Wu, Yong-Hong
    Jiang, Wen-Bo
    Pan, Xue-Li
    Tian, Miao-Xin
    Xin, Zhen-Tao
    Dianwang Jishu/Power System Technology, 2010, 34 (01): : 208 - 213