Study of the glow discharge mode in high-frequency instant-start fluorescent lamps

被引:0
|
作者
机构
[1] Somogyvari, Zoltan
[2] Almosdi, Peter
关键词
Cathode dark space; Cathode fall; Electrode; Fluorescent lamp; Glow discharge; Instant start; Rapid cycling; Sputtering;
D O I
10.2150/jlve.ieij130000505
中图分类号
学科分类号
摘要
Steady-state glow discharge operation has been studied on model fluorescent lamps equipped with bare tungsten electrode filaments. Energy transfer mechanisms were measured by electrode temperatures as a function of electric driving parameters and fill gas pressure. The measurements were evaluated and discussed by application of plasma models of the cathode dark space region.
引用
收藏
页码:66 / 70
页数:4
相关论文
共 21 条
  • [11] Effect of surface modification of high-density polyethylene by direct current and radio frequency glow discharge on wetting and adhesion characteristics
    S. Bhowmik
    T. K. Chaki
    S. Ray
    F. Hoffman
    L. Dorn
    Metallurgical and Materials Transactions A, 2004, 35 : 865 - 877
  • [12] Comparative study of high-power pulsed sputtering (HPPS) glow plasma techniques using Penning discharge and hollow-cathode discharge
    Azuma, Kingo
    Mieda, Ryosuke
    Yukimura, Ken
    Tamagaki, Hiroshi
    Okimoto, Tadao
    SURFACE & COATINGS TECHNOLOGY, 2011, 206 (05) : 938 - 942
  • [13] Preventing IR interference between infrared waves emitted by high-frequency fluorescent lighting systems and infrared remote controls
    Kataoka, S
    Atagi, K
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (01) : 239 - 245
  • [14] MASS-SPECTROMETRY STUDY OF A MAGNETRON PLANAR GLOW-DISCHARGE EXCITED IN THE DIRECT-CURRENT AND IN THE RADIOFREQUENCY MODE - AN EXPERIMENTAL-DESIGN APPROACH
    MOLLE, C
    SPRINGAEL, S
    WAUTELET, M
    DAUCHOT, JP
    HECQ, M
    APPLIED SPECTROSCOPY, 1995, 49 (07) : 872 - 879
  • [15] Effect of high-frequency alternating current transcutaneous stimulation over muscle strength: a controlled pilot study
    Serrano-Munoz, Diego
    Avendano-Coy, Juan
    Simon-Martinez, Cristina
    Taylor, Julian
    Gomez-Soriano, Julio
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2018, 15
  • [16] Optical characteristics of capillary U-tube Ar-Hg high frequency glow discharge plasmas and its application for ammonia compound contaminated water treatments
    Uchida, Y
    Urashima, K
    Chang, JS
    Kaneda, T
    Uchida, Y
    Shimazaki, K
    Tomita, Y
    Watanabe, S
    JOURNAL OF ADVANCED OXIDATION TECHNOLOGIES, 2002, 5 (02) : 186 - 192
  • [17] Numerical study on discharge characteristics in ultra-high frequency band modulated by pulses with electrodes covered by barriers
    Gao Shu-Han
    Wang Xu-Cheng
    Zhang Yuan-Tao
    ACTA PHYSICA SINICA, 2020, 69 (11)
  • [18] Study of Gaseous Sample Ionization by Excited Particles Formed in Glow Discharge Using High-Resolution Orthogonal Acceleration Time-of-Flight Mass Spectrometer
    I. V. Sulimenkov
    V. S. Brusov
    V. V. Zelenov
    M. G. Skoblin
    V. V. Filatov
    A. R. Pikhtelev
    V. I. Kozlovskii
    Journal of Analytical Chemistry, 2017, 72 : 1331 - 1339
  • [19] Study of Gaseous Sample Ionization by Excited Particles Formed in Glow Discharge Using High-Resolution Orthogonal Acceleration Time-of-Flight Mass Spectrometer
    Sulimenkov, I. V.
    Brusov, V. S.
    Zelenov, V. V.
    Skoblin, M. G.
    Filatov, V. V.
    Pikhtelev, A. R.
    Kozlovskii, V. I.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 72 (13) : 1331 - 1339
  • [20] Feasibility study of monitoring of plasma etching chamber conditions using superimposed high-frequency signals on rf power transmission line
    Kasashima, Y.
    Uesugi, F.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (10)