Optimization design and shaking table test of tuned mass damper for enhancing seismic performance in thermal power plants

被引:0
|
作者
Shi, Luwei [1 ]
Peng, Lingyun [1 ]
Zhang, Ruhan [1 ]
Kang, Yingjie [2 ]
Guan, Yaxi [1 ]
Li, Wenzhi [1 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing 100124, Peoples R China
[2] Shijiazhuang Tiedao Univ, Key Lab Rd & Railway Engn Safety Control, Minist Educ, Shijiazhuang 050043, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal power plant; Tuned mass damper; Optimized design; Equivalence model; Adjustable damping; Shaking table test; VIBRATION CONTROL;
D O I
10.1016/j.istruc.2024.107405
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aimed to improve the seismic performance of traditional thermal power plant structures. Taking a certain thermal power plant as the research object, a simplified three-floor equivalent model was designed, aiming to achieve similar fundamental periods and considering the floor height and mass distribution. A coal bunker was used as the mass unit in the tuned mass damper (TMD) design. The optimal TMD design parameters for the two orthogonal directions of the structure were determined using the steady-state complex modal decomposition method and fixed-point theory. Moreover, a velocity-dependent and adjustable damping electromagnetic damping device were designed as the damping unit in the TMD. Shaking table tests were conducted in two orthogonal directions to investigate the control effects in the interstory drift angle, floor acceleration, and top-floor displacement response, thus verifying the effectiveness and feasibility of the TMD scheme. The effectiveness of the vibration control under the abovementioned optimal TMD design scheme was further validated through finite element simulations of the original thermal power plant structure. This study demonstrates that due to the process requirements of thermal power plant structures, the coal hunker has a massive weight and is positioned at a high location. Based on this characteristic, directly using coal bunkers as mass units for the TMD with the optimal parameter design can significantly reduce the various seismic responses, achieving a 25 % to 45 % seismic reduction rate.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Optimization of the Seismic Performance of a Steel-Concrete Wind Turbine Tower with the Tuned Mass Damper
    Yue, Yanchao
    Li, Changxin
    Jia, Kai
    Zhang, Yuhang
    Tian, Jingjing
    BUILDINGS, 2022, 12 (09)
  • [22] Shaking Table Test for Evaluation of Seismic Behavior of Nuclear Power Plants on Non-Rock Site
    Li X.
    Wang X.
    He Q.
    Liu A.
    Wang, Xiaohui (wangxiaohui5000@163.com), 1600, Atomic Energy Press (38): : 31 - 35
  • [23] Seismic control performance and experimental study of multiple pounding tuned rolling mass damper
    Fan, Peiran
    Li, Shujin
    Mao, Ling
    EARTHQUAKES AND STRUCTURES, 2023, 24 (04) : 247 - 258
  • [24] Performance-cost optimization of tuned mass damper under low-moderate seismic actions
    Greco, Rita
    Marano, Giuseppe Carlo
    Fiore, Alessandra
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2016, 25 (18): : 1103 - 1122
  • [25] A Shaking Table Test Design on Seismic Strengthened Brick Masonry Structures
    Liu Jie Ping
    Liu Chen
    Zhang Ling Xin
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON ADVANCED DESIGN AND MANUFACTURING ENGINEERING, 2015, 39 : 568 - 574
  • [26] Seismic performance analysis of rocking wall TMDs structure based on shaking table test
    Nie W.
    Liu S.
    Lu S.
    Liu S.
    Yin C.B.A.H.
    Earthquake and Structures, 2021, 21 (01): : 23 - 36
  • [27] Performance of tuned particle impact damper and tuned mass damper seismic control systems considering mainshock-aftershock
    Soureshjani, Omid Karimzade
    Lavassani, Seyed Hossein Hosseini
    STRUCTURES, 2023, 56
  • [28] Shaking table test of comparison and optimization of seismic performance of slope reinforcement with multi-anchor piles
    Pai, Li Fang
    Wu, Hong Gang
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 145 (145)
  • [29] Conceptual design and shaking table test of a new passive damper for wind turbine towers
    Dai, Kaoshan, 1600, Chinese Society of Civil Engineering (47):
  • [30] Stochastic design of multiple tuned mass damper system under seismic excitation
    Bhowmik, Kamalesh
    Debnath, Nirmalendu
    ARCHIVE OF APPLIED MECHANICS, 2022, 92 (01) : 383 - 404