Outlook of Corona Discharge as DeNO x Technology

被引:3
作者
Patino, David [1 ]
Franco-Sardinha, Amanda [1 ]
Deive, Francisco J. [2 ]
Porteiro, Jacobo [1 ]
机构
[1] Univ Vigo, Grp Tecnol Energet GTE, CINTECX, Vigo 36310, Spain
[2] Univ Vigo, CINTECX, Vigo 36310, Spain
关键词
COMPRESSION IGNITION ENGINES; AIR-POLLUTION CONTROL; NEGATIVE DC CORONA; NITRIC-OXIDE; NITROGEN-OXIDES; NOX REDUCTION; GAS COMPOSITIONS; FLUE-GAS; PLASMA; REMOVAL;
D O I
10.1021/acs.energyfuels.4c03495
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This review explores the efficacy of corona discharge (CD) as a non-thermal plasma (NTP) technology for the reduction of nitrogen oxides (NOx) from combustion gases. The NTP is generated when a treated gas is subjected to a large electric field, resulting in the ionization of gas molecules without a significant thermal energy increase. NTP operates post-combustion at low temperatures, favoring NOx reduction through the generation of reactive species, such as O, O-3, OH, and various nitrogen radicals. These species facilitate the conversion of NO to NO2, which can be further reduced or absorbed. The review analyses the effect of different gas compositions on the effectiveness of the CD process. Oxygen enhances NOx reduction by generating additional oxidizing species, while water vapor contributes through the formation of OH radicals and the dissolution of nitric and nitrous acids. The polarity of the applied voltage significantly impacts the ionization process and the extent of the plasma region, with negative polarity generally providing better results in terms of NOx reduction. Additionally, the use of pulsed corona discharge (PCD) shows higher energy efficiency compared to continuous direct current (DC) discharge due to optimized electron generation. The temperature influences the effectiveness of NTP, with higher temperatures potentially reducing the efficiency due to the decomposition of reactive species, like O-3. The optimal residence time and initial NOx concentration are also crucial for maximizing reduction efficiency while maintaining energy efficiency. Overall, CD is presented as a promising DeNO(x) technology, particularly when optimized for gas composition, voltage polarity, and discharge nature.
引用
收藏
页码:20141 / 20154
页数:14
相关论文
共 62 条
[11]   Modeling nitrogen chemistry in combustion [J].
Glarborg, Peter ;
Miller, James A. ;
Ruscic, Branko ;
Klippenstein, Stephen J. .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2018, 67 :31-68
[12]   Air pollution control by electrical discharges [J].
Hackam, R ;
Akiyama, H .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2000, 7 (05) :654-683
[13]   Transformations and destruction of nitrogen oxides -: NO, NO2 and N2O -: in a pulsed corona discharge reactor [J].
Hu, XD ;
Zhang, JJ ;
Mukhnahallipatna, S ;
Hamann, J ;
Biggs, MJ ;
Agarwal, P .
FUEL, 2003, 82 (13) :1675-1684
[14]   High-Efficiency Removal of NOx From Flue Gas by Multitooth Wheel-Cylinder Corona Discharge Plasma Facilitated Selective Catalytic Reduction Process [J].
Jiang, Nan ;
Shang, Ke-Feng ;
Lu, Na ;
Li, Hu ;
Li, Jie ;
Wu, Yan .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2016, 44 (11) :2738-2744
[15]   Oxidation efficiency of elemental mercury in two DBD plasma reactors [J].
Jiang, Yuze ;
An, Jiutao ;
Shang, Kefeng ;
Jiang, Diwen ;
Li, Jie ;
Lu, Na ;
Wu, Yan .
7TH INTERNATIONAL CONFERENCE ON APPLIED ELECTROSTATICS (ICAES-2012), 2013, 418
[16]   Plasma oxidation of NO in O2:N2 mixtures: The importance of back-reaction [J].
Jogi, Indrek ;
Levoll, Erik ;
Raud, Juri .
CHEMICAL ENGINEERING JOURNAL, 2016, 301 :149-157
[17]   Nonthermal plasma processing for air-pollution control: A historical review, current issues, and future prospects [J].
Kim, HH .
PLASMA PROCESSES AND POLYMERS, 2004, 1 (02) :91-110
[18]   Kinetic scheme of the non-equilibrium discharge in nitrogen-oxygen mixtures [J].
Kossyi, I. A. ;
Kostinsky, A. Yu ;
Matveyev, A. A. ;
Silakov, V. P. .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 1992, 1 (03) :207-220
[19]   Application of pulsed corona induced plasma chemical process to an industrial incinerator [J].
Lee, YH ;
Jung, WS ;
Choi, YR ;
Oh, JS ;
Jang, SD ;
Son, YG ;
Cho, MH ;
Namkung, W ;
Koh, DJ ;
Mok, YS ;
Chung, JW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (11) :2563-2567
[20]   Removal of NOx with radical injection caused by corona discharge [J].
Lin, H ;
Gao, X ;
Luo, ZY ;
Cen, KF ;
Huang, Z .
FUEL, 2004, 83 (10) :1349-1355