Numerical modelling of corneal biomechanical behaviour

被引:58
作者
Elsheikh, Ahmed [1 ]
Wang, Defu [1 ]
机构
[1] Division of Civil Engineering, University of Dundee
关键词
Biomechanical behaviour; Cornea; Intraocular pressure; Numerical modelling;
D O I
10.1080/10255840600976013
中图分类号
学科分类号
摘要
Numerical modelling based on finite element analysis is used to represent the biomechanical behaviour of the cornea. The construction details of the model including the discretisation method, the mesh density, the thickness distribution, the topography idealisation, the boundary conditions and the material properties, are optimised to improve efficiency. Factors which are found to have a considerable effect on model accuracy are considered and those with effect below a certain low threshold are ignored to reduce cost of analysis. The model is validated against laboratory tests involving pressure inflation of corneal trephinates while monitoring their behaviour. To illustrate the potential of the validated model in studying corneal biomechanics, its use in modelling Goldmann applanation tonometry (GAT) is briefly described. In studying GAT, the model is able to accurately trace the behaviour of the cornea under tonometric pressure and monitor the gap closure and the progress of deformation to the point of applanation. © 2007 Taylor & Francis.
引用
收藏
页码:85 / 95
页数:10
相关论文
共 24 条
[1]  
Anderson K., El-Sheikh A., Newson T., Application of structural analysis to the mechanical behaviour of the cornea, J. R. Soc. Interface, 1, pp. 1-13, (2004)
[2]  
Anderson K., The application of structural engineering to corneal biomechanics, (2005)
[3]  
Bryant M.R., McDonnell P.J., Constitutive laws for bio-mechanical modelling of refractive surgery, J. Bio-Mech. Eng, 118, pp. 473-481, (1996)
[4]  
Buzard K.A., Introduction to bio-mechanics of the cornea, Refract. Corneal Surg, 8, pp. 127-138, (1992)
[5]  
Ehlers N., Bramsen T., Sperling S., Applanation tonometry and central corneal thickness, Acta Ophthalmol (Copenhagen), 53, pp. 34-43, (1975)
[6]  
Feltgen N., Leifert D., Funk J., Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings, Br. J. Ophthalmol, 85, pp. 85-87, (2001)
[7]  
Goldmann H., Schmidt T., Uber applanations-tonometrie, Ophthalmologica, 134, (1961)
[8]  
Greene P.R., Mechanical aspects of myopia, (1978)
[9]  
Abaqus: Standard Users Manual, (2005)
[10]  
Hjortdal J.O., Regional elastic performance of the human cornea, J. Biomech, 29, 7, pp. 931-942, (1993)