Evaluation of induced voltage and current on low-voltage distribution lines under EHV/UHV AC and DC transmission lines

被引:0
|
作者
He, Yuwei [1 ]
Liu, Yakun [1 ]
Yan, Nannan [2 ]
Li, Shilong [1 ]
Wei, Bengang [2 ]
Wang, Liming [2 ]
Fu, Zhengcai [1 ]
机构
[1] Key Laboratory of Control of Power Transmission and Conversion, Shanghai Jiao Tong University, Ministry of Education, Minhang District, Shanghai,200030, China
[2] State Grid Shanghai Municipal Electric Power Company, Pudong New District, Shanghai,200437, China
来源
关键词
D O I
10.13335/j.1000-3673.pst.2015.09.040
中图分类号
学科分类号
摘要
In order to guarantee personnel safety during maintenance of low-voltage distribution lines, it's necessary to evaluate induced voltage and current on the lines under maintenance. EMTP models are adopted to calculate the induced voltage and current on 380 V distribution lines parallel to and beneath four extra high voltage(EHV)/ultra high voltage(UHV) AC and DC transmission lines in Shanghai area, respectively. The factors impacting on induced voltage and current are analyzed. Simulation results show that large voltage and current are induced on 380 V distribution lines and maximum induced voltage varies from 30 kV to 70 kV. A new device is developed for eliminating induced voltage on such low-voltage distribution lines. Experimental results show that the device can be used to ground both ends of the distribution line under maintenance and eliminate induced voltage effectively. ©, 2015, Power System Technology Press. All right reserved.
引用
收藏
页码:2640 / 2646
相关论文
共 50 条
  • [21] Circuit analysis and computation of secondary current in EHV and UHV transmission lines
    Chen, He
    Chen, Wei-Xian
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (10): : 2368 - 2373
  • [22] EARTHING OF LOW-VOLTAGE OVERHEAD LINES
    NERGER, D
    ENERGIETECHNIK, 1979, 29 (05): : 189 - 195
  • [23] MAINTENANCE OF LOW-VOLTAGE OVERHEAD TRANSMISSION-LINES AND WORK UNDER LIVE CONDITIONS
    KUHNEL, H
    ENERGIETECHNIK, 1978, 28 (08): : 312 - 313
  • [24] A Solution for Indoor Distribution of Overhead Low-voltage Lines in Distribution Network
    Qian Yong
    Zhang Bin-Bin
    Shen A-Mei
    Wang Xiao-Bing
    Ma Zhong-Wen
    2019 3RD INTERNATIONAL WORKSHOP ON RENEWABLE ENERGY AND DEVELOPMENT (IWRED 2019), 2019, 267
  • [25] A field study of lightning overvoltages on low-voltage distribution lines
    Tokyo Electric Power Company, 1-1-3, Uchisaiwai-cho, Chiyoda-ku, Tokyo 100-8560, Japan
    IEEJ Trans. Power Energy, 6 (516-523):
  • [26] A field study of lightning overvoltages in low-voltage distribution lines
    Ishii, Tsunayoshi
    Oguchi, Syuichi
    Sakamoto, Yoshiki
    Okabe, Shigemitsu
    ELECTRICAL ENGINEERING IN JAPAN, 2013, 183 (02) : 12 - 21
  • [27] Voltage instability and collapse of series compensated EHV transmission lines
    Tripathy, SC
    Viswanathan, B
    Heydeman, J
    ELECTRIC MACHINES AND POWER SYSTEMS, 1998, 26 (06): : 601 - 615
  • [28] An approach for random load transfer in low-voltage distribution network using DC tie lines
    Zhang, Xiaoyong
    Hu, Tingli
    Xu, Ruilin
    Xiong, Xiaofu
    Wang, Ruimiao
    Song, Zhongyou
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (23): : 83 - 88
  • [29] Comparison of Low-Voltage AC and DC Distribution Networks for EV Charging
    Huynh, Wayne
    Tran The Hoang
    Ukil, Abhisek
    Nair, Nirmal-Kumar C.
    2022 7TH IEEE WORKSHOP ON THE ELECTRONIC GRID (EGRID), 2022,
  • [30] Research on Complex Gap Discharge Model of Live Working on EHV and UHV High-Voltage Transmission Lines
    Wang, Linong
    Zhang, Qiushi
    Hu, Jianxun
    Liu, Kai
    Wu, Tian
    Wang, Junhua