Optimisation of cone beam CT radiotherapy imaging protocols using a novel 3D printed head and neck anthropomorphic phantom

被引:1
作者
Alzahrani, Meshal [1 ,2 ,3 ]
O'Hara, Christopher [1 ]
Bird, David [1 ]
Baldwin, Jack P. C. [1 ]
Naisbit, Mitchell [1 ]
Teh, Irvin [2 ]
Broadbent, David A. [1 ,2 ]
Al-Qaisieh, Bashar [1 ]
Johnstone, Emily [4 ]
Speight, Richard [1 ,2 ]
机构
[1] Leeds Teaching Hosp NHS Trust, Dept Med Phys & Engn, Leeds, England
[2] Univ Leeds, Sch Med, Biomed Imaging Sci Dept, Leeds, England
[3] King Abdulaziz Univ, Fac Appl Med Sci, Dept Radiol Sci, Jeddah, Saudi Arabia
[4] Christie NHS Fdn Trust, Christie Med Phys & Engn, Manchester, England
关键词
cone beam computed tomography; radiotherapy; anthropomorphic phantom; optimisation; MODERN RADIATION-THERAPY; COMPUTED-TOMOGRAPHY; GUIDANCE PROCEDURES; DOSIMETRY; QUALITY;
D O I
10.1088/1361-6560/ad88d2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. This study aimed to optimise Cone Beam Computed Tomography (CBCT) protocols for head and neck (H&N) radiotherapy treatments using a 3D printed anthropomorphic phantom. It focused on precise patient positioning in conventional treatment and adaptive radiotherapy (ART). Approach. Ten CBCT protocols were evaluated with the 3D-printed H&N anthropomorphic phantom, including one baseline protocol currently used at our centre and nine new protocols. Adjustments were made to milliamperage and exposure time to explore their impact on radiation dose and image quality. Additionally, the effect on image quality of varying the scatter correction parameter for each of the protocols was assessed. Each protocol was compared against a reference CT scan. Usability was assessed by three Clinical Scientists using a Likert scale, and statistical validation was performed on the findings. Main results. The work revealed variability in the effectiveness of protocols. Protocols optimised for lower radiation exposure maintained sufficient image quality for patient setup in a conventional radiotherapy pathway, suggesting the potential for reducing patient radiation dose by over 50% without compromising efficacy. Optimising ART protocols involves balancing accuracy across brain, bone, and soft tissue, as no single protocol or scatter correction parameter achieves optimal results for all simultaneously. Significance. This study underscores the importance of optimising CBCT protocols in H&N radiotherapy. Our findings highlight the potential to maintain the usability of CBCT for bony registration in patient setup while significantly reducing the radiation dose, emphasizing the significance of optimising imaging protocols for the task in hand (registering to soft tissue or bone) and aligning with the as low as reasonably achievable principle. More studies are needed to assess these protocols for ART, including CBCT dose measurements and CT comparisons. Furthermore, the novel 3D printed anthropomorphic phantom demonstrated to be a useful tool when optimising CBCT protocols.
引用
收藏
页数:14
相关论文
共 39 条
[1]   Optimisation of Varian TrueBeam head, thorax and pelvis CBCT based on patient size [J].
Agnew, Christina E. ;
McCallum, Candice ;
Johnston, Gail ;
Workman, Adam ;
Irvine, Denise M. .
JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (03) :248-256
[2]   Imaging dose from cone beam computed tomography in radiation therapy [J].
Alaei, Parham ;
Spezi, Emiliano .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07) :647-658
[3]   Metallic materials in the exomass impair cone beam CT voxel values [J].
Candemil, Amanda P. ;
Salmon, Benjamin ;
Freitas, Deborah Q. ;
Ambrosano, Glaucia M. B. ;
Haiter-Neto, Francisco ;
Oliveira, Matheus L. .
DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (06)
[4]   Risk of second cancers in the era of modern radiation therapy: does the risk/benefit analysis overcome theoretical models? [J].
Chargari, Cyrus ;
Goodman, Karyn A. ;
Diallo, Ibrahima ;
Guy, Jean-Baptiste ;
Rancoule, Chloe ;
Cosset, Jean-Marc ;
Deutsch, Eric ;
Magne, Nicolas .
CANCER AND METASTASIS REVIEWS, 2016, 35 (02) :277-288
[5]   Synthetic CT generation from CBCT images via unsupervised deep learning [J].
Chen, Liyuan ;
Liang, Xiao ;
Shen, Chenyang ;
Nguyen, Dan ;
Jiang, Steve ;
Wang, Jing .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (11)
[6]   EVALUATION OF RADIATION DOSE AND IMAGE QUALITY FOR THE VARIAN CONE BEAM COMPUTED TOMOGRAPHY SYSTEM [J].
Cheng, Harry C. Y. ;
Wu, Vincent W. C. ;
Liu, Eva S. F. ;
Kwong, Dora L. W. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01) :291-300
[7]   Image Guided Radiation Therapy (IGRT) Technologies for Radiation Therapy Localization and Delivery [J].
De Los Santos, Jennifer ;
Popple, Richard ;
Agazaryan, Nzhde ;
Bayouth, John E. ;
Bissonnette, Jean-Pierre ;
Bucci, Mary Kara ;
Dieterich, Sonja ;
Dong, Lei ;
Forster, Kenneth M. ;
Indelicato, Daniel ;
Langen, Katja ;
Lehmann, Joerg ;
Mayr, Nina ;
Parsai, Ishmael ;
Salter, William ;
Tomblyn, Michael ;
Yuh, William T. C. ;
Chetty, Indrin J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (01) :33-45
[8]   A study on adaptive IMRT treatment planning using kV cone-beam CT [J].
Ding, George X. ;
Duggan, Dennis M. ;
Coffey, Charles W. ;
Deeley, Matthew ;
Hallahan, Dennis E. ;
Cmelak, Anthony ;
Malcolm, Arnold .
RADIOTHERAPY AND ONCOLOGY, 2007, 85 (01) :116-125
[9]   Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180 [J].
Ding, George X. ;
Alaei, Parham ;
Curran, Bruce ;
Flynn, Ryan ;
Gossman, Michael ;
Mackie, T. Rock ;
Miften, Moyed ;
Morin, Richard ;
Xu, X. George ;
Zhu, Timothy C. .
MEDICAL PHYSICS, 2018, 45 (05) :E84-E99
[10]   Radiation exposure to patients from image guidance procedures and techniques to reduce the imaging dose [J].
Ding, George X. ;
Munro, Peter .
RADIOTHERAPY AND ONCOLOGY, 2013, 108 (01) :91-98