Microwave Signal Replicator Design for Testing of the Multi-Channel Transcranial Magnetic Stimulator

被引:0
|
作者
Chen Q. [1 ,2 ]
Zhang K. [1 ]
Pang J. [1 ]
Zhang S. [1 ]
Feng G. [1 ]
Wu C. [1 ]
Li W. [3 ]
机构
[1] National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei
[2] Laboratory for Big Data and Decision, Hefei
[3] Advanced Manufacturing Engineering College, Hefei University, Hefei
关键词
AD9361; Field-Programmable Gate Array (FPGA); geriatric rehabilitation; multi-channel transcranial magnetic stimulation; Radio Frequency (RF) signal source; signal duplication;
D O I
10.26599/IJCS.2024.9100002
中图分类号
学科分类号
摘要
The multi-channel transcranial magnetic stimulator is commonly used for rehabilitation treatment of ischemic cerebrovascular disease, neurosis, and brain injury diseases in the elderly. And multiple high coherency signals are required as inputs for its test, which are with consistent frequency, adjustable amplitude, equal magnitude, and long-time phase consistency ⩽±1°. But ordinary signal sources have only one output channel, which is far from meeting the test requirements. If the traditional power division is used for the duplication, the phase difference between the channels will be larger than ±1°. If the multi-throw Radio Frequency (RF) switch is used, it will seriously affect the phase consistency of the input signal and increase the distortion of the signal. In order to solve the above problems, the method to extend the output of the microwave signal source has been proposed in the paper by using the integrated transceiver AD9361. The proposed method can realize the duplication of the number of signal channels according to user requirements. Then a signal replicator has been designed by combining AD9361 chip and Field-Programmable Gate Array (FPGA) control module. The experimental platform has been built to test the performance of the designed device. Experimental results show that the duplicated signals are highly consistent with the source signal in the power amplitude and frequency, meanwhile the phase of the duplicated signals are all highly consistent with each other. © The author(s) 2024.
引用
收藏
页码:83 / 87
页数:4
相关论文
共 50 条
  • [1] Design and simulation of multi-channel brain magnetic stimulator
    Wang, Xue-Min
    Chen, Yun
    Guo, Ming-Xia
    Wang, Ming-Shi
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2006, 39 (06): : 717 - 721
  • [2] Design of multi-channel transcranial DC stimulator based on STM32
    Tang, Li
    Tang, Xuehua
    Zhou, Zhiyong
    2022 IEEE INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, BIG DATA AND ALGORITHMS (EEBDA), 2022, : 1060 - 1062
  • [3] A fast and efficient algorithm for multi-channel transcranial magnetic stimulation (TMS) signal denoising
    Jinzhen Liu
    Kaiwen Tian
    Hui Xiong
    Yu Zheng
    Medical & Biological Engineering & Computing, 2022, 60 : 2479 - 2492
  • [4] A MULTI-CHANNEL ISOLATED STIMULATOR
    UJEC, E
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1968, 24 (03): : 274 - &
  • [5] A fast and efficient algorithm for multi-channel transcranial magnetic stimulation (TMS) signal denoising
    Liu, Jinzhen
    Tian, Kaiwen
    Xiong, Hui
    Zheng, Yu
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2022, 60 (09) : 2479 - 2492
  • [6] A Circuit System Design for Implantable Multi-channel neural stimulator
    Xi, Yan
    Du, Qian
    Gong, Hanyan
    Tang, Nan
    Cao, Lei
    Niu, Jinhai
    Ren, Qiushi
    APCMBE 2008: 7TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, 2008, 19 : 58 - 61
  • [7] Simultaneous Multi-Channel Microwave Photonic Signal Processing
    Chen, Lawrence R.
    Moslemi, Parisa
    Ma, Ming
    Adams, Rhys
    PHOTONICS, 2017, 4 (04)
  • [8] Development of Multi-channel Brain Stimulator
    An, Hyejin
    Shin, Hyun-Chool
    2018 32ND INTERNATIONAL CONFERENCE ON INFORMATION NETWORKING (ICOIN), 2018, : 840 - 842
  • [9] Testing a Multi-Channel Service Design Method
    Simons, Luuk P. A.
    Bouwman, W. A. G. A.
    21ST BLED ECONFERENCE ECOLLABORATION: OVERCOMING BOUNDARIES THROUGH MULTI-CHANNEL INTERACTION, CONFERENCE PROCEEDINGS, 2008, : 336 - 350
  • [10] Design of Multi-channel Electrical Stimulator Integrated with Online Impedance Measurement
    Yang, Dapeng
    Huang, Qi
    Jiang, Zainan
    Jiang, Li
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2020, 40 (06) : 943 - 950