Design of Raman spectroscopy measurement system based on shifted excitation method using two laser diodes with different wavelengths

被引:0
作者
Wang X. [1 ]
Wu J. [1 ]
Fan X. [1 ]
Xu Y. [1 ]
Lu X. [1 ]
Zuo Y. [2 ]
机构
[1] School of Aerospace Engineering, Xiamen University, Xiamen
[2] The 1st Metrology & Measurement Research Center of National Defense Science Industry of China, Changcheng Institute of Metrology & Measurement, Beijing
来源
Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering | 2016年 / 45卷 / 01期
关键词
Fluorescence suppression; Raman spectroscopy; Reconstruction algorithm; Shifted excitation;
D O I
10.3788/IRLA201645.0106005
中图分类号
学科分类号
摘要
Raman detection is often disturbed by fluorescence background, while Shifted Excitation Raman Difference Spectroscopy (SERDS) is an effective method for fluorescent suppression on Raman spectroscopy. Based on this method, a Raman spectroscopy measurement system was designed using two closely space fixed-wavelength laser diodes stabilized with the Volume Bragg Gratings. The output wavelength of laser diodes was stabilized by manipulating their power and temperature. The light path and circuit of spectral data acquisition were designed with back-thinned area array CCD with high sensitivity. Besides, the three different reconstruction algorithms of the difference spectrum, namely simple integration algorithm, simple integration with data interpolation algorithm and multiple energy constraint iterative deconvolution algorithm could be realized through software of this system. The Raman spectra of sesame oil of some brand in the presence of a highly fluorescent were measured with this system and then the spectra reconstructed with three different algorithms to process the difference spectrum respectively were compared. Experimental results show that the system designed in this paper can effectively reject the effect of fluorescence to the Raman spectroscopy measurement. © 2016, Editorial Board of Journal of Infrared and Laser Engineering. All right reserved.
引用
收藏
页数:6
相关论文
共 16 条
  • [1] Wu B., Chen K., Wang H., Composition dependence of molecular interactions in ethanol-water mixture studied by laser Raman spectra, Infrared and Laser Engineering, 42, pp. 68-73, (2013)
  • [2] Fan X., Wang X., Xu Y., Et al., Design of Raman spectroscopy measurement system based on SHINERS, Infrared and Laser Engineering, 42, 7, pp. 1798-1803, (2013)
  • [3] Matousek P., Towrie M., Stanley A., Et al., Efficient rejection of fluorescence from Raman spectra using picosecond Kerr gating, Applied Spectroscopy, 53, 12, pp. 1485-1489, (1999)
  • [4] Chase B., FT-Raman spectroscopy: a catalyst for the Raman explosion, Journal of Chemical Education, 84, 1, pp. 75-80, (2007)
  • [5] Mosier-Boss P.A., Lieberman S.H., Newbery R., Fluorescence rejection in Raman spectroscopy by shifted-spectra, edge detection, and FFT filtering techniques, Applied Spectroscopy, 49, 5, pp. 630-638, (1995)
  • [6] Zhao J., Lui H., McLean D.I., Et al., Automated autofluorescence background subtraction algorithm for biomedical Raman spectroscopy, Applied Spectroscopy, 61, 11, pp. 1225-1232, (2007)
  • [7] Lieber C.A., Mahadevan-Jansen A., Automated method for subtraction of fluorescence from biological Raman spectra, Applied Spectroscopy, 57, 11, pp. 1363-1367, (2003)
  • [8] Bertinetto C.G., Vuorinen T., Automatic baseline recognition for the correction of large sets of spectra using continuous wavelet transform and iterative fitting, Applied Spectroscopy, 68, 2, pp. 155-164, (2014)
  • [9] Shreve A.P., Cherepy N.J., Mathies R.A., Effective rejection of fluorescence interference in Raman spectroscopy using a shifted excitation difference technique, Applied Spectroscopy, 46, 4, pp. 707-711, (1992)
  • [10] Matousek P., Towrie M., Parker A.W., Simple reconstruction algorithm for shifted excitation Raman difference spectroscopy, Applied Spectroscopy, 59, 6, pp. 848-851, (2005)