Research of single-stage boost-buck inverter with three-switch devices

被引:0
作者
Ye M. [1 ]
Cai H. [2 ]
Song P. [1 ]
机构
[1] School of Electrical and Automation, East China Jiaotong University, Nanchang
[2] Jiangxi Electric Power Design Institute, Nanchang
来源
Gaodianya Jishu/High Voltage Engineering | 2016年 / 42卷 / 10期
基金
中国国家自然科学基金;
关键词
Buck-boost inverter; Distributed generation; Grid generation; Harmonic distortion; Small-signal model; Topology configuration;
D O I
10.13336/j.1003-6520.hve.20160926009
中图分类号
学科分类号
摘要
In order to solve the problem that the input source of distributed generator system usually varies in a large scale, a new 3-switch single-stage single-phase buck-boost inverter is proposed. The inverter can meet a wide input voltage range with independent load operation and power grid operation, and it has the least switch, simple control, and high efficiency. By analyzing each working mode equivalent circuit and mathematical modeling, we compare the difference between discontinuous conduction mode(DCM) and continuous conduction mode(CCM) control mode, deduce the AC small signal model by DCM, and put forward a new closed-loop SPWM control strategy. The simulation and experimental results verify that this topology can operate under standalone and grid-connected when input voltage varies from 50 V to 300 V. Furthermore, output current waveforms can satisfy the requirements of grid, and the efficiency of whole inverter exceeds 90%. © 2016, High Voltage Engineering Editorial Department of CEPRI. All right reserved.
引用
收藏
页码:3092 / 3101
页数:9
相关论文
共 16 条
[1]  
Zeng Z., Zhao R., Tang S., Et al., An overviewon advanced grid-connected inverters used for decentralized renewable energy resources, Proceedings of the CSEE, 33, 24, pp. 1-13, (2013)
[2]  
Tan X., Feng G., Wang H., Et al., Three-phase four-switch grid-connected photovoltaic inverter combined with active power filter, High Voltage Engineering, 40, 11, pp. 3590-3596, (2014)
[3]  
Zhou L., Zhang L., Li H., Et al., Negative component compensation control scheme for photovoltaic grid-connected inverter, High Voltage Engineering, 39, 5, pp. 1197-1203, (2013)
[4]  
Yazdani A., Fazio A.R.D., Ghoddami H., Et al., Modeling guidelines and a benchmark for power system simulation studies of three-phase single-stage photovoltaic systems, IEEE Transactions on Power Delivery, 26, 2, pp. 1247-1263, (2011)
[5]  
Zhou L., Zhang L., Liao B., Et al., Research on control strategy of single-phase photovoltaic inverter, Power System Technology, 36, 9, pp. 25-30, (2012)
[6]  
Ma L., Research on topology and control of photovoltaic grid connected inverter without transformer, (2011)
[7]  
Gu J., Chen G., A current-sensor-less MPPT algorithm for single-stage grid-connected PV inverters, Proceedings of the CSEE, 32, 27, pp. 149-153, (2012)
[8]  
Xue Y., Chang L., Kjar S.B., Et al., Topologies of single-phase inverters for small distributed power generators: an overview, IEEE Transactions on Power Electronics, 19, 5, pp. 1305-1314, (2004)
[9]  
Nagao M., Harada K., Power flow of photovoltaic system using buck-boost PWM power inverter, Proceedings of IEEE Power Electronics and Drive Systems, pp. 144-149, (1997)
[10]  
Wang C.M., A novel single-stage full-bridge buck-boost inverter, Proceedings of IEEE Applied Power Electronics Conference, pp. 51-57, (2003)