Comparison of soft X-ray spectro-ptychography and scanning transmission X-ray microscopy

被引:0
作者
Hitchcock, Adam P. [1 ]
Zhang, Chunyang [1 ,2 ]
Eraky, Haytham [1 ]
Higgins, Drew [2 ]
Belkhou, Rachid [3 ]
Millle, Nicolas [3 ]
Swaraj, Sufal [3 ]
Stanescu, Stefan [3 ]
Sun, Tianxiao [4 ,5 ]
Wang, Jian [4 ]
机构
[1] McMaster Univ, Chem & Chem Biol, Hamilton, ON L8S4M1, Canada
[2] McMaster Univ, Chem Engn, Hamilton, ON L8S4M, Canada
[3] LOrme Merisiers, Synchrotron SOLEIL, partementale 128, F-91190 St aubin, France
[4] Canadian Light Source, 44 Innovat Blvd, Saskatoon, SK S7N 2V3, Canada
[5] Univ Texas Austin, Walker Dept Mech Engn, Austin, TX 78712 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Spectro-ptychography; Cu nanoparticles; Cu 2p X-ray absorption; Scanning transmission X-ray microscopy; STXM; IN-SITU; RESOLUTION; SPECTROMICROSCOPY; ELECTRON; RECONSTRUCTION; BEAMLINE; CARBON;
D O I
10.1016/j.elspec.2024.147487
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Over the past decade advances in instrumentation and software have enabled development of spectro-ptychography (SP) as a higher spatial resolution extension of scanning transmission X-ray microscopy (STXM). Direct comparisons are made of same-area chemical state imaging of Cu nanoparticles using STXM and SP in order to compare and contrast the two approaches. We show that SP gives very similar chemical state information as STXM with significantly better spatial resolution and much higher quality images and chemical maps, on account of finer pixels in the reconstructed images. When defocused spot sizes are used (i.e., 1-3 mu m, as opposed to full-focus 30-50 nm) SP data acquisition is faster and the radiation dose delivered to the sample is smaller than the corresponding STXM measurement. The limitations of SP are primarily related to the time and complexity of the ptychographic reconstruction. We argue that these documented advantages mean that SP rather than STXM should be used for more complex studies such as tomography and in situ studies, especially when radiation damage is a concern. The main point of this manuscript is to illustrate, with scientifically relevant samples, the significant advantages of SP relative to conventional STXM, with the goal of encouraging greater use of SP.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Characterizing magnetism of individual magnetosomes by X-ray magnetic circular dichroism in a scanning transmission X-ray microscope
    Lam, Karen P.
    Hitchcock, Adam P.
    Obst, Martin
    Lawrence, John R.
    Swerhone, George D. W.
    Leppard, Gary G.
    Tyliszczak, Tolek
    Karunakaran, Chithra
    Wang, Jian
    Kaznatcheev, Konstantin
    Bazylinski, Dennis A.
    Lins, Ulysses
    CHEMICAL GEOLOGY, 2010, 270 (1-4) : 110 - 116
  • [42] Scanning transmission X-ray microscopy with a fast, framing pixel detector
    Menzel, A.
    Kewish, C. M.
    Kraft, P.
    Henrich, B.
    Jefimovs, K.
    Vila-Comamala, J.
    David, C.
    Dierolf, M.
    Thibault, P.
    Pfeiffer, F.
    Bunk, O.
    ULTRAMICROSCOPY, 2010, 110 (09) : 1143 - 1147
  • [43] Investigation of amorphous to crystalline phase transition of sodium titanate by X-ray absorption spectroscopy and scanning transmission X-ray microscopy
    Liu, Jian
    Wang, Biqiong
    Banis, Mohammad N.
    Wang, Zhiqiang
    Li, Ruying
    Wang, Jian
    Hu, Yongfeng
    Sham, Tsun-Kong
    Sun, Xueliang
    CANADIAN JOURNAL OF CHEMISTRY, 2017, 95 (11) : 1163 - 1169
  • [44] X-Ray Diffraction Microscopy
    Thibault, Pierre
    Elser, Veit
    ANNUAL REVIEW OF CONDENSED MATTER PHYSICS, VOL 1, 2010, 1 : 237 - 255
  • [45] X-ray microscopy
    Lider, V. V.
    PHYSICS-USPEKHI, 2017, 60 (02) : 187 - 203
  • [46] Scanning Transmission X-Ray Microscopy as a Novel Tool to Probe Colloidal and Photonic Crystals
    van Schooneveld, Matti M.
    Hilhorst, Jan
    Petukhov, Andrei V.
    Tyliszczak, Tolek
    Wang, Jian
    Weckhuysen, Bert M.
    de Groot, Frank M. F.
    de Smit, Emiel
    SMALL, 2011, 7 (06) : 804 - 811
  • [47] Soft X-ray spectro-tomography study of cyanobacterial biomineral nucleation
    Obst, M.
    Wang, J.
    Hitchcock, A. P.
    GEOBIOLOGY, 2009, 7 (05) : 577 - 591
  • [48] Simultaneous X-ray fluorescence and scanning X-ray diffraction microscopy at the Australian Synchrotron XFM beamline
    Jones, Michael W. M.
    Phillips, Nicholas W.
    van Riessen, Grant A.
    Abbey, Brian
    Vine, David J.
    Nashed, Youssef S. G.
    Mudie, Stephen T.
    Afshar, Nader
    Kirkham, Robin
    Chen, Bo
    Balaur, Eugeniu
    de Jonge, Martin D.
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1151 - 1157
  • [49] Possibilities and Challenges of Scanning Hard X-ray Spectro-microscopy Techniques in Material Sciences
    Somogyi, Andrea
    Mocuta, Cristian
    AIMS MATERIALS SCIENCE, 2015, 2 (02) : 122 - 161
  • [50] Monitoring the fate of copper nanoparticles in river biofilms using scanning transmission X-ray microscopy (STXM)
    Lawrence, John R.
    Dynes, James J.
    Korber, Darren R.
    Swerhone, George D. W.
    LeppardD, Gary G.
    Hitchcock, Adam P.
    CHEMICAL GEOLOGY, 2012, 329 : 18 - 25