Influence of the cold end heat exchanger geometry on the pulse tube cooler performance

被引:0
|
作者
机构
[1] [1,Pang, Xiao-Min
[2] Wang, Xiao-Tao
[3] Dai, Wei
[4] Luo, Er-Cang
[5] 1,Zhang, Xiang-Zheng
来源
Wang, Xiao-Tao (xtwang@mail.ipc.ac.cn) | 1600年 / Science Press卷 / 37期
关键词
Cooling Capacity - Cooling performance - Displacement amplitudes - End heat exchangers - Gas gaps - Length - Pulse tube coolers - System efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
Improving the performance of the pulse tube cooler is one of the important targets of recent study. Besides the regenerator and phase shifters, heat exchangers also play important roles, especially the cold end heat exchanger which has strong influence on the system efficiency and cooling capacity. This paper mainly studied the influence of the cold end heat exchanger geometry such as length and the gas gap geometry on the cooling performance of a 100 Hz pulse tube cooler. In this study, the system performs better when the length of the cold end exchanger is around the displacement amplitude of gas parcels. With the same heat exchange area, increasing the gas gap appropriately is beneficial to the cooling capacity. © 2016, Science Press. All right reserved.
引用
收藏
相关论文
共 50 条
  • [1] Experimental study of the influence of cold heat exchanger geometry on the performance of a co-axial pulse tube cooler
    Pang, Xiaomin
    Dai, Wei
    Wang, Xiaotao
    Vanapalli, S.
    Luo, Ercang
    CRYOGENICS, 2016, 78 : 78 - 82
  • [2] Development and design of cold heat exchanger of pulse tube cooler
    Dong, W
    Lucentini, M
    Naso, V
    35TH INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE & EXHIBIT (IECEC), VOLS 1 AND 2, TECHNICAL PAPERS, 2000, : 420 - 423
  • [3] Performance improvement of cold heat exchanger for high power single-stage pulse tube cooler
    Dong, W. Q.
    Qiu, L. M.
    Gan, Z. H.
    Sun, H.
    He, Y. L.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 196 - 199
  • [4] Analysis of pulse tube cooler with cold-end reservoir
    Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China
    Zhejiang Daxue Xuebao (Gongxue Ban), 2007, 4 (598-602):
  • [5] Influence of the Water-Cooled Heat Exchanger on the Performance of a Pulse Tube Refrigerator
    Wang, Wei
    Hu, Jianying
    Xu, Jingyuan
    Zhang, Limin
    Luo, Ercang
    APPLIED SCIENCES-BASEL, 2017, 7 (03):
  • [6] Optimizing the tube geometry to enhance thermohydraulic performance of tube bank heat exchanger
    Aktas, Arif Emre
    Kuru, Muhammet Nasif
    Erdinc, Mehmet Tahir
    Aydin, Orhan
    Bilgili, Mehmet
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 193
  • [7] Performance study of a fin and tube heat exchanger with different fin geometry
    Department of Energy Technology, Aalborg University, Aalborg, Denmark
    ECOS - Proc. Int. Conf. Effic., Cost, Optim., Simul. Environ. Impact Energy Syst.,
  • [8] Numerical Analysis of Geometry Influence on Heat Transfer in a Slotted Fin and Tube Heat Exchanger
    Torbarina, Fran
    Trp, Anica
    Lenic, Kristian
    HEAT TRANSFER ENGINEERING, 2023, 44 (05) : 411 - 425
  • [9] Performance of a counterflow heat exchanger with heat loss through the wall at the cold end
    Department of Mechanical Engineering, Indian Inst. of Technology, 600 036, Chennai, India
    Cryogenics, 1 (43-52):
  • [10] Performance of a counterflow heat exchanger with heat loss through the wall at the cold end
    Narayanan, SP
    Venkatarathnam, G
    CRYOGENICS, 1999, 39 (01) : 43 - 52