Comparison of MCNPX and FLUKA Monte Carlo codes in the simulating a nuclear gauge

被引:0
|
作者
Mohtaram S. [1 ]
Tajik M. [1 ]
Peyvandi R.G. [2 ]
机构
[1] School of Physics, Damghan University, PO Box 36716-41167, Damghan
[2] Department of Physics, Shahrood University of Technology, Shahrood
关键词
FLUKA; MCNPX; Nuclear gauge; Rod detector;
D O I
10.1016/j.apradiso.2021.109603
中图分类号
学科分类号
摘要
In this paper, a nuclear gauge was simulated using MCNPX and FLUKA codes. This device consists of a fluid-containing vessel, three BC400 rod plastic scintillator and a60Co gamma source. Simulation studies show that the changes in the count of each of the three detectors and the sum of their counts decrease with increasing vessel water height. The simulation results were compared with the measurement results. Comparison results show that the mean count difference between MCNPX code and experimental results is about 3% lower than FLUKA code, but the computation time using FLUKA code is approximately 2.8 times less than the MCNPX code. © 2021 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [1] Comparison of MCNPX and FLUKA Monte Carlo codes in the simulating a nuclear gauge
    Mohtaram, Saeid
    Tajik, Mojtaba
    Peyvandi, Reza Gholipour
    APPLIED RADIATION AND ISOTOPES, 2021, 170
  • [2] INTERCOMPARISION OF MONTE CARLO RADIATION TRANSPORT CODES MCNPX, GEANT4, AND FLUKA FOR SIMULATING PROTON RADIOTHERAPY OF THE EYE
    Randeniya, S. D.
    Taddei, P. J.
    Newhauser, W. D.
    Yepes, P.
    NUCLEAR TECHNOLOGY, 2009, 168 (03) : 810 - 814
  • [3] Intercomparision of Monte Carlo Radiation Transport Codes MCNPX, GEANT4 and FLUKA for Simulating Proton Radiation Therapy of the Eye
    Randeniya, S.
    Yepes, P.
    Newhauser, W.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [4] Monte-carlo simulations:: FLUKA vs. MCNPX
    Oden, M.
    Krasa, A.
    Majerlel, M.
    Svoboda, O.
    Wagner, V.
    NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2007, 958 : 219 - 221
  • [5] Effect of dental filling materials on electron beam radiotherapy dose distribution in head region: A monte carlo study by FLUKA and MCNPX codes
    Rezai M.R.
    Shahheidarypoor R.
    Mohammadi S.
    Parvaresh P.
    Iranian Journal of Medical Physics, 2020, 17 (03) : 183 - 187
  • [6] Voxel dosimetry: Comparison of MCNPX and DOSXYZnrc Monte Carlo codes in patient specific phantom calculations
    Hadad, Kamal
    Saeedi-Moghadam, Mahdi
    Zeinali-Rafsanjani, Banafsheh
    TECHNOLOGY AND HEALTH CARE, 2017, 25 (01) : 29 - 35
  • [7] Applications of FLUKA Monte Carlo code for nuclear and accelerator physics
    Battistoni, Giuseppe
    Broggi, Francesco
    Brugger, Markus
    Campanella, Mauro
    Carboni, Massimo
    Empl, Anton
    Fasso, Alberto
    Gadioli, Ettore
    Cerutti, Francesco
    Ferrari, Alfredo
    Ferrari, Anna
    Lantz, Matthias
    Mairani, Andrea
    Margiotta, M.
    Morone, Cristina
    Muraro, Silvia
    Parodi, Katia
    Patera, Vincenzo
    Pelliccioni, Mauricio
    Pinsky, Larry
    Ranft, Johannes
    Roesler, Stefan
    Rollet, Sofia
    Sala, Paola R.
    Santana, Mario
    Sarchiapone, Lucia
    Sioli, Massimiliano
    Smirnov, George
    Sommerer, Florian
    Theis, Christian
    Trovati, Stefania
    Villari, R.
    Vincke, Heinz
    Vincke, Helmut
    Vlachoudis, Vasilis
    Vollaire, Joachim
    Zapp, Neil
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (24): : 2850 - 2856
  • [8] Experimental test of Monte Carlo proton transport at grazing incidence in GEANT4, FLUKA and MCNPX
    Kimstrand, Peter
    Tilly, Nina
    Ahnesjo, Anders
    Traneus, Erik
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (04): : 1115 - 1129
  • [9] Nuclear reactions in Monte Carlo codes
    Ferrari, A
    Sala, PR
    RADIATION PROTECTION DOSIMETRY, 2002, 99 (1-4) : 29 - 38
  • [10] A COMPARISON BETWEEN MONTE-CARLO ALGORITHMS FOR SIMULATING LATTICE GAUGE-THEORIES
    BERNASCHI, M
    FERNANDEZ, LA
    PHYSICS LETTERS B, 1988, 212 (02) : 211 - 215