Total focusing method of ultrasonic annular array and its application

被引:0
|
作者
Li W. [1 ]
Zhou Z. [1 ,2 ]
Li Y. [1 ]
机构
[1] School of Mechanical Engineering and Automation, Beihang University, Beijing
[2] State Key Laboratory of Acoustics, Institute of Acoustic, Chinese Academy of Sciences, Beijing
来源
Li, Wentao (liwentao@buaa.edu.cn) | 2020年 / Chinese Society of Astronautics卷 / 41期
基金
中国国家自然科学基金;
关键词
Annular array transducers; Detection of high attenuation material; Three-dimensional imaging; Total focusing methods; Ultrasonic arrays;
D O I
10.7527/S1000-6893.2020.23657
中图分类号
学科分类号
摘要
Detection accuracy and maximum detection depth in large thickness components with high attenuation often pose a challenge for conventional linear ultrasonic arrays or planar ultrasonic arrays because of the serious loss of acoustic energy of phased array ultrasonic beams in the non-focused area. In this study, a three-dimensional acoustic field distribution model of synthetic beams is first established to analyze the characteristics of acoustic energy distribution of different ultrasonic array transducers. It is found that the annular ultrasonic transducer has a better acoustic field at the same focus depth and a fully symmetric beam focal spot with fewer elements. Then, a Total Focusing Method (TFM) applied to annular ultrasonic arrays and a group velocity optimization method of anisotropic material detection are proposed. In this method, the full matrix data is reconstructed along the axial line of the transducer to realize pointwise infinity focusing along the depth. Finally, experiments on a 3D printed titanium alloy specimen with prefabricated defects are conducted based on the developed ultrasonic array immersion C-scan system. The experimental results show that the annular array transducer based on the TFM algorithm can achieve accurate detection of the flat bottom hole and the transverse hole defects with a diameter of 0.8 mm and depth of 5 mm in the 55 mm thick specimen. Compared with the conventional dynamic depth focusing method, the C-scan images of the TFM have a better signal to noise ratio and quantitative accuracy. © 2020, Beihang University Aerospace Knowledge Press. All right reserved.
引用
收藏
相关论文
共 20 条
  • [1] DRINKWATER B W, WILCOX P D., Ultrasonic arrays for non-destructive evaluation: A review, NDT & E International, 39, 7, pp. 525-541, (2006)
  • [2] WILCOX P D, HOLMES C, DRINKWATER B W., Advanced reflector characterization with ultrasonic phased arrays in NDE applications, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 54, 8, pp. 1541-1550, (2007)
  • [3] SONG S J, SHIN H J, JANG Y H., Development of an ultrasonic phased array system for non-destructive tests of nuclear power plant components, Nuclear Engineering Design, 214, 1-2, pp. 151-161, (2002)
  • [4] YANG P, GUO J T, SHI K R, Et al., Progress in 3D imaging by 2D phased array, Nondestructive Testing, 29, 4, pp. 177-180, (2007)
  • [5] LAI P X, ZHANG B X, WANG C H., Radiation and reflection acoustical fields of an annular phased array, Acta Acustica, 32, 3, pp. 212-220, (2007)
  • [6] HAZARD C R, FISHER R A, MILLS D M, Et al., Annular array beamforming for 2D arrays with reduced system channels, Proceedings of the IEEE Ultrasonics Symposium, pp. 1859-1862, (2003)
  • [7] SHA Z X, LIANG J, LI Y., Vari-aperture focusing inspection technique based on ultrasonic annular phased array, Failure Analysis and Prevention, 14, 2, pp. 84-89, (2019)
  • [8] LANE C J L, DUNHILL A K, DRINKWATER B W, Et al., The inspection of anisotropic single-crystal components using a 2-D ultrasonic array, IEEE Transaction on Ultrasonics, Ferroelectrics, and Frequency Control, 57, 12, pp. 2742-2752, (2010)
  • [9] KOLKOORI S R, RAHMAN M U, CHINTA P K, Et al., Ultrasonic field profile evaluation in acoustically inhomogeneous anisotropic materials using 2D ray tracing model: Numerical and experimental comparison, Ultrasonics, 53, 2, pp. 396-411, (2013)
  • [10] PORTZGEN N, GISOLF D, BLACQUIERE G., Inverse wave field extrapolation: A different NDI approach to imaging defects, IEEE Transaction on Ultrasonics, Ferroelectrics, and Frequency Control, 54, 1, pp. 118-127, (2007)