Flow injection non-enzymatic amperometric detection of hydrogen peroxide based on a glassy carbon electrode modified with silver particles on glassy carbon spherical powder

被引:0
|
作者
机构
[1] [1,2,Sirisaeng, Thanaporn
[2] 1,2,Thavarungkul, Panote
[3] 1,2,Kanatharana, Proespichaya
[4] 1,2,Limbut, Warakorn
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This work reports the development of a non-enzymatic electrochemical sensor for hydrogen peroxide based on a glassy carbon electrode modified with glassy carbon spherical powder carrying silver particles (AgPs-GCS/GCE). In this work, AgPs were synthesized on GCS by electroless deposition. The surface morphology and electrochemical behavior of the AgPs-GCS/GCE were characterized by scanning electron microscopy (SEM) and cyclic voltammetry, respectively. The average diameter of the AgPs on GCS was 673 ± 89 nm. The AgPs-GCS/GCE exhibited excellent electrocatalytic activity for the reduction of hydrogen peroxide. The proposed modified electrode was incorporated in a flow injection amperometry system (FI-Amp). The optimized fabrication and operational conditions included the amount of AgPs-GCS covering the GCE, and the applied potential, flow rate and sample volume. Under optimal conditions, the proposed method provided a wide linear range (0.25–350 μg mL−1) (r = 0.999) with high sensitivity (5.75 μA mg L−1 cm−2). The limit of detection (LOD) and limit of quantitation (LOQ) were 0.12 μg mL−1 and of 0.38 μg mL−1, respectively. This sensor exhibited good repeatability (RSD 1) and the developed method successfully detected hydrogen peroxide in hair dyes and cotton samples with good recoveries (90 ± 2% to 106 ± 2%). © 2018 The Electrochemical Society.
引用
收藏
相关论文
共 50 条
  • [41] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Jiang, Bin-Bin
    Wei, Xian-Wen
    Wu, Fang-Hui
    Wu, Kong-Lin
    Chen, Le
    Yuan, Guo-Zan
    Dong, Chao
    Ye, Yin
    MICROCHIMICA ACTA, 2014, 181 (11-12) : 1463 - 1470
  • [42] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Bin-Bin Jiang
    Xian-Wen Wei
    Fang-Hui Wu
    Kong-Lin Wu
    Le Chen
    Guo-Zan Yuan
    Chao Dong
    Yin Ye
    Microchimica Acta, 2014, 181 : 1463 - 1470
  • [43] A glassy carbon electrode modified with FeS nanosheets as a highly sensitive amperometric sensor for hydrogen peroxide
    Jin, Jiayi
    Wu, Wenqin
    Min, Hui
    Wu, Huimin
    Wang, Shengfu
    Ding, Yu
    Yang, Shuijin
    MICROCHIMICA ACTA, 2017, 184 (05) : 1389 - 1396
  • [44] A glassy carbon electrode modified with FeS nanosheets as a highly sensitive amperometric sensor for hydrogen peroxide
    Jiayi Jin
    Wenqin Wu
    Hui Min
    Huimin Wu
    Shengfu Wang
    Yu Ding
    Shuijin Yang
    Microchimica Acta, 2017, 184 : 1389 - 1396
  • [45] A novel enzymatic glucose biosensor and sensitive non-enzymatic hydrogen peroxide sensor based on graphene and cobalt oxide nanoparticles composite modified glassy carbon electrode
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Veeramani, Vediyappan
    Periakaruppan, Prakash
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 450 - 456
  • [46] DETERMINATION OF PENTACHLOROPHENOL BY FLOW-INJECTION AND AMPEROMETRIC DETECTION WITH A GLASSY-CARBON ELECTRODE
    YANEZSEDENO, P
    GUIJARRO, EC
    CARRAZON, JMP
    DIEZ, LMP
    MICROCHEMICAL JOURNAL, 1990, 41 (03) : 366 - 371
  • [47] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a composite consisting of chitosan‐encapsulated graphite and platinum nanoparticles
    Tse-Wei Chen
    Selvakumar Palanisamy
    Shen-Ming Chen
    Microchimica Acta, 2016, 183 : 2861 - 2869
  • [48] Lanthanum Sulfide Nanorods Modified Glassy Carbon Electrode as Non-Enzymatic Biosensor for Xanthine
    Javeed, Zainab
    Ibrahim, Muhammad
    Iqbal, Muhammad Faisal
    Nawaz, Rahat
    Hussain, Dilshad
    Ayub, Muhammad
    Ashiq, Muhammad Naeem
    Majeed, Saadat
    Najam-ul-Haq, Muahmmad
    Fatima, Batool
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (11)
  • [49] Modified glassy carbon electrode based on myoglobin and reduced graphene oxide for hydrogen peroxide detection
    Szoke, A.
    Turdean, G.
    Muresan, L.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2017, 49 : 147 - 154
  • [50] Amperometric biosensor for hydrogen peroxide based on electrodeposited sub-micrometer gold modified glassy carbon electrode
    Wang, SQ
    Chen, J
    Lin, XQ
    CHINESE JOURNAL OF CHEMISTRY, 2004, 22 (04) : 360 - 364