Flow injection non-enzymatic amperometric detection of hydrogen peroxide based on a glassy carbon electrode modified with silver particles on glassy carbon spherical powder

被引:0
|
作者
机构
[1] [1,2,Sirisaeng, Thanaporn
[2] 1,2,Thavarungkul, Panote
[3] 1,2,Kanatharana, Proespichaya
[4] 1,2,Limbut, Warakorn
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This work reports the development of a non-enzymatic electrochemical sensor for hydrogen peroxide based on a glassy carbon electrode modified with glassy carbon spherical powder carrying silver particles (AgPs-GCS/GCE). In this work, AgPs were synthesized on GCS by electroless deposition. The surface morphology and electrochemical behavior of the AgPs-GCS/GCE were characterized by scanning electron microscopy (SEM) and cyclic voltammetry, respectively. The average diameter of the AgPs on GCS was 673 ± 89 nm. The AgPs-GCS/GCE exhibited excellent electrocatalytic activity for the reduction of hydrogen peroxide. The proposed modified electrode was incorporated in a flow injection amperometry system (FI-Amp). The optimized fabrication and operational conditions included the amount of AgPs-GCS covering the GCE, and the applied potential, flow rate and sample volume. Under optimal conditions, the proposed method provided a wide linear range (0.25–350 μg mL−1) (r = 0.999) with high sensitivity (5.75 μA mg L−1 cm−2). The limit of detection (LOD) and limit of quantitation (LOQ) were 0.12 μg mL−1 and of 0.38 μg mL−1, respectively. This sensor exhibited good repeatability (RSD 1) and the developed method successfully detected hydrogen peroxide in hair dyes and cotton samples with good recoveries (90 ± 2% to 106 ± 2%). © 2018 The Electrochemical Society.
引用
收藏
相关论文
共 50 条
  • [31] Non-enzymatic amperometric glucose sensing on CuO/mesoporous TiO2 modified glassy carbon electrode
    Ali, Muhammad
    Mir, Sadullah
    Ahmed, Safeer
    RSC ADVANCES, 2023, 13 (37) : 26275 - 26286
  • [32] Non-enzymatic sensing of glucose and hydrogen peroxide using a glassy carbon electrode modified with a nanocomposite consisting of nanoporous copper, carbon black and nafion
    Ling Mei
    Pengcheng Zhang
    Jiyun Chen
    Dandan Chen
    Ying Quan
    Ning Gu
    Genhua Zhang
    Rongjing Cui
    Microchimica Acta, 2016, 183 : 1359 - 1365
  • [33] Non-enzymatic sensing of glucose and hydrogen peroxide using a glassy carbon electrode modified with a nanocomposite consisting of nanoporous copper, carbon black and nafion
    Mei, Ling
    Zhang, Pengcheng
    Chen, Jiyun
    Chen, Dandan
    Quan, Ying
    Gu, Ning
    Zhang, Genhua
    Cui, Rongjing
    MICROCHIMICA ACTA, 2016, 183 (04) : 1359 - 1365
  • [34] Non-Enzymatic Glucose Sensors for Sensitive Amperometric Detection Based on Simple Method of Nickel Nanoparticles Decorated on Magnetite Carbon Nanotubes Modified Glassy Carbon Electrode
    Nontawong, Nongyao
    Amatatongchai, Maliwan
    Jarujamrus, Purim
    Tamuang, Suparb
    Chairam, Sanoe
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (02): : 1362 - 1376
  • [35] A reagentless non-enzymatic hydrogen peroxide sensor presented using electrochemically reduced graphene oxide modified glassy carbon electrode
    Mutyala, Sankararao
    Mathiyarasu, Jayaraman
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 69 : 398 - 406
  • [36] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a composite consisting of chitosanaEuroencapsulated graphite and platinum nanoparticles
    Chen, Tse-Wei
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    MICROCHIMICA ACTA, 2016, 183 (11) : 2861 - 2869
  • [37] Non-enzymatic determination of purine nucleotides using a carbon dot modified glassy carbon electrode
    Karthikeyan, R.
    Nelson, D. James
    John, S. Abraham
    ANALYTICAL METHODS, 2019, 11 (30) : 3866 - 3873
  • [38] An Amperometric Sensitive Hydrogen Peroxide Sensor Based on a Silver Nanoparticle-Doped Polyimide-Modified Glassy Carbon Electrode
    Chen, Lin
    Wang, Yue
    Ban, Hao
    Yu, Simin
    Tao, Dongping
    Hu, Zhizhi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (11): : 10961 - 10972
  • [39] A non-enzymatic hydrogen peroxide sensor based on poly(vinyl alcohol)-multiwalled carbon nanotubes-platinum nanoparticles hybrids modified glassy carbon electrode
    Fang, Yuxin
    Zhang, Di
    Qin, Xia
    Miao, Zhiying
    Takahashi, Shigehiro
    Anzai, Jun-ichi
    Chen, Qiang
    ELECTROCHIMICA ACTA, 2012, 70 : 266 - 271
  • [40] Non-Enzymatic Electrochemical Detection for Uric Acid Based on a Glassy Carbon Electrode Modified With MOF-71
    Abrori, Syauqi Abdurrahman
    Septiani, Ni Luh Wulan
    Hakim, Fahmi Nur
    Maulana, Angga
    Suyatman
    Nugraha
    Anshori, Isa
    Yuliarto, Brian
    IEEE SENSORS JOURNAL, 2021, 21 (01) : 170 - 177