Simulation of position-sensitive γ-ray detector based on plastic scintillating fiber array

被引:0
作者
Electronic Engineering Institute, Hefei, China [1 ]
不详 [2 ]
机构
[1] Electronic Engineering Institute, Hefei
[2] Department of Modern Physics, University of Science and Technology of China, Hefei
来源
Qiangjiguang Yu Lizishu | / 7卷
关键词
Compton edge; Monte Carlo; Plastic scintillating fiber; Position-sensitive detector;
D O I
10.11884/HPLPB201527.076004
中图分类号
学科分类号
摘要
In the last decade a great effort has been made to develop the position-sensitive device for γ-ray imaging and pixel detectors, scintillation or semiconductor, have been widely used. Currently the the MeV γ-ray spectroscopy has been desired in many fields. Unfortunately, there is no existing γ-ray spectroscopy that performs perfectly in such energy range and some detector systems have been proposed for the purpose. As commonly used for pixel detectors, scintillating fibers have the advantage of that they may achieve both the spatial and energy resolution in detecting γ-rays. We simulate the electron spectrum produced in the fiber via Compton scattering mechanism only and energy deposition spectrum including the photoelectron and electron-positron pair creation mechanisms to the interactions with γ-ray photons. We can see that the spectrum might allow determining the energy of the incoming γ-rays, if the Compton edge of the spectrum can be determined. The results of the simulation also show that the energy resolution can be achieved about 10%, and the cross-talks affect little on energy resolution in the bundle configuration. For detecting γ-rays with energies in the range of several MeV, a fiber of radius of about a few centimeters needs to be used to achieve this resolution. These results suggest that the detector configuration might be used in achieving certain degree energy resolution in detecting γ-rays under certain circumstances. Since we choose the low mass material to achieve high probability of Compton scattering, another problem is that the detection efficiency for PSF in this energy range is quite low. It is about 15% or less. There exists a contradiction to obtain both well. ©, 2015, Editorial Office of High Power Laser and Particle Beams. All right reserved.
引用
收藏
页数:5
相关论文
共 12 条
  • [1] Verger L., Gentet M.C., Gerfault L., Et al., Performance and perspectives of a CdZnTe-based gamma camera for medical imaging, IEEE Trans on Nucl Sci, 51, 61, pp. 3111-3117, (2004)
  • [2] Floyd C.E., Bender J.E., Sharma A.C., Et al., Introduction to neutron stimulated emission computed tomography, Physics Medical Biology, 51, 14, pp. 3375-3390, (2006)
  • [3] Bross A.D., Scintillating plastic optical fiber radiation detectors in high energy particle physics, Proc of SPIE, 1592, pp. 122-132, (1991)
  • [4] Singkarat S., Garis N.S., Grosshog G., The feasibility of using plastic scintillation fibers for fast neutron spectrometry, Nuclear Instrument Method A, 335, 1-2, pp. 248-254, (1993)
  • [5] Yu B., Su M., Liu S., Et al., Simulation on spatial resolution of scintillator arrays based on neutron penumbral imaging system, High Power Laser and Particle Beams, 24, 8, pp. 1826-1830, (2012)
  • [6] Nasseri M.M., Ma Q.L., Yin Z.J., Et al., Low energy X-ray imaging using plastic scintillating fiber: A simulation study, Nuclear Instrument Method B, 234, pp. 362-368, (2005)
  • [7] Cherry S.R., Shao Y., Siegel S.B., High resolution detector array for gamma-ray imaging
  • [8] Levin C.S., Tornai M.P., Cherry S.R., Et al., Compton scatter and X-ray cross-talk and the use of very thin inter-crystal septa in high resolution PET detectors, IEEE Trans on Nucl Sci, 44, 2, pp. 218-224, (1997)
  • [9] Li G., Zhang B., Deng L., Et al., Development of Monte Carlo particle transport code JMCT, High Power Laser and Particle Beams, 25, 1, pp. 158-162, (2013)
  • [10] Melnyk R., Dibianca F.A., Monte Carlo study of X-ray cross-talk in a variable resolution X-ray detector, Proc of SPIE, 5030, pp. 694-701, (2003)