Development of an 11 T BSCCO Insert Coil for a 25 T Cryogen-free Superconducting Magnet

被引:1
作者
Hanai S. [1 ]
Tsuchihashi T. [1 ]
Ioka S. [1 ]
Watanabe K. [2 ]
Awaji S. [2 ]
Oguro H. [2 ,3 ]
机构
[1] Toshiba Corporation, Yokohama
[2] High Field Laboratory for Superconducting Materials, Institute for Materials Research, Tohoku University, Sendai
[3] Department of Materials Science, School of Engineering, Tokai University, Hiratsuka
关键词
cryogen-free; high tensile strength; HTS coil; performance test; Superconducting magnet;
D O I
10.1109/TASC.2017.2657689
中图分类号
学科分类号
摘要
We have developed and installed an 11 T Bi2Sr2Ca2Cu3Oy (BSCCO) insert coil for a 25 T cryogen-free superconducting magnet (25 T-CSM). The insert coil composed of a stack of 38 double pancakes was wound with DI-BSCCOTM Type HT-NX conductors which had high critical tensile strength of 400 MPa at 77 K. The insert coil is cooled by two two-stage Gifford-McMahon cryocoolers and the operation temperature of the insert coil is designed to be below 10 K. The insert coil has successfully generated 11.48 T without a background field and 24.57 T with a 14.0 T background field produced by outer low temperature superconducting coils in a 52 mm room temperature bore. Before the performance test, we fabricated and tested an R&D insert coil consisting of two double pancakes, which had the same configuration as the actual insert coil pancakes do, to confirm mechanical strength of the conductors. © 2002-2011 IEEE.
引用
收藏
相关论文
共 48 条
  • [21] Cryogen-Free 23 T Superconducting Magnet Employing an YBa2Cu3O7 Coated Conductor Insert
    K. Watanabe
    S. Awaji
    G. Nishijima
    S. Hanai
    [J]. Journal of Superconductivity and Novel Magnetism, 2011, 24 : 993 - 997
  • [22] Performance Test of 1.5 T Cryogen-Free Orthopedic MRI Magnet
    Bagdinov, Anton
    Demikhov, Evgeny
    Kostrov, Evgeny
    Lysenko, Valeriy
    Piskunov, Nikolay
    Rybakov, Alexander
    Tysyachnykh, Yuri
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (03)
  • [23] 8 T Cryogen Free Magnet With a Variable Temperature Insert Using a Heat Switch
    Demikhov, E.
    Kostrov, E.
    Lysenko, V.
    Piskunov, N.
    Troitskiy, V.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 612 - 615
  • [24] Gradient coil design with enhanced shielding constraint for a cryogen-free superconducting MRI system
    Wang, Yaohui
    Wang, Weimin
    Liu, Hui
    Chen, Shunzhong
    Liu, Feng
    Wang, Qiuliang
    [J]. MAGNETIC RESONANCE LETTERS, 2024, 4 (01)
  • [25] Test Results for a 1.5 T MRI System Utilizing a Cryogen-free YBCO Magnet
    Slade, Robert A.
    Parkinson, Benjamin J.
    Walsh, Rowan M.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (03)
  • [26] Optimization of peltier current leads for 5T cryogen-free superconducting magnets
    Sasaki, A.
    Kasukabe, T.
    Oue, M.
    Hamabe, M.
    Nakamura, K.
    Yamaguchi, S.
    Ninomiya, A.
    Okumura, H.
    Kawamura, K.
    Aoki, I.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOL 52A & 52B, 2006, 824 : 384 - +
  • [27] 11 T liquid helium-free superconducting magnet
    Watanabe, K
    Awaji, S
    Sakuraba, J
    Watazawa, K
    Hasebe, T
    Jikihara, K
    Yamada, Y
    Ishihara, M
    [J]. CRYOGENICS, 1996, 36 (12) : 1019 - 1025
  • [28] Design and Preliminary Tests of a 20-T REBCO Insert Coil for a 35-T All Superconducting Magnet
    Zhang, Xintao
    Liu, Huajun
    Liu, Fang
    Shao, Liangjun
    Hu, Shuai
    Qu, Timing
    Zhu, Jiamin
    Liu, Sheng
    Ma, Hongjun
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (03) : 1 - 5
  • [29] A compact 3T all HTS cryogen-free MRI system
    Parkinson, B. J.
    Slade, R. A.
    Bouloukakis, K.
    [J]. SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2017, 30 (12)
  • [30] Recent Development of the 25 T All-Superconducting Magnet at IEE
    Liu, Jianhua
    Wang, Lei
    Qin, Lang
    Wang, Qiuliang
    Dai, Yinming
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (04)