Permanent faults identification using least squares fitting algorithm for three-phase reclosure in transmission lines with shunt reactors

被引:0
|
作者
Liang, Zhenfeng [1 ,2 ]
Suonan, Jiale [1 ]
Kang, Xiaoning [1 ]
Song, Guobing [1 ]
机构
[1] School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
[2] Institute of Water Resources and Hydro-Electric Engineering, Xi'an University of Technology, Xi'an 710048, China
关键词
13;
D O I
10.7652/xjtuxb201306015
中图分类号
学科分类号
摘要
引用
收藏
页码:85 / 89
相关论文
共 50 条
  • [1] Identification of permanent faults for three-phase adaptive reclosure of the transmission lines with shunt reactors
    Shao, Wen-Quan
    Song, Guo-Bing
    Suonan, Jia-Le
    Liang, Zhen-Feng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (04): : 91 - 98
  • [2] Permanent faults identification using free oscillation frequency for three-phase reclosure on transmission lines with shunt reactors
    Liang, Z. (lzf@xaut.edu.cn), 1600, Chinese Society for Electrical Engineering (33):
  • [3] Identification of permanent faults for three-phase autoreclosing using inductance parameter on transmission lines with shunt reactors
    Qiao, Zhanjun
    Fan, Wenbo
    International Journal of Smart Home, 2013, 7 (05): : 197 - 206
  • [4] Identification of permanent faults for single-phase auto-reclosure on transmission lines with shunt reactors
    Electrical Engineering Department, Xi'an Jiaotong University, Xi'an 710049, China
    Zhongguo Dianji Gongcheng Xuebao, 2006, 11 (75-81):
  • [5] Permanent faults identification based on mode component for three-phase autoreclosing on transmission lines with shunt reactors
    Suonan, Jiale
    Liang, Zhenfeng
    Song, Guobing
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (25): : 81 - 86
  • [6] Identification of three-phase permanent or temporary fault at transmission lines with shunt reactors
    Li, Yong-Li
    Li, Bo-Tong
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (01): : 82 - 90
  • [7] Identification of permanent faults for three-phase adaptive reclosure based on waveform characteristics of differential mode currents in shunt reactors
    Wang, Qingqing
    Wang, Huifang
    Lin, Da
    He, Benteng
    Dianwang Jishu/Power System Technology, 2015, 39 (04): : 1127 - 1132
  • [8] Three-phase adaptive reclosure for transmission lines with shunt reactors using mode current oscillation frequencies
    Huang, Xinghua
    Song, Guobing
    Wang, Ting
    Gu, Yaobin
    JOURNAL OF ENGINEERING-JOE, 2018, (15): : 1012 - 1017
  • [9] Fault nature identification for single-phase adaptive reclosure on transmission lines with shunt reactors
    Xi'an University of Science and Technology, Xi'an 710054, China
    不详
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2008, 32 (06): : 81 - 84
  • [10] Identification of permanent faults based on differential current protection for transmission lines with two shunt reactors
    Xi'an Jiaotong University, Xi'an 710049, China
    Dianli Xitong Zidonghue, 2007, 20 (56-60):