This paper describes the frequency dependence of the partial discharge characteristics in a needle-plane electrode system under sine wave applied voltage 50 Hz to 10000 Hz. We measured the pulse occurrence frequency, the maximum discharge magnitude, the φ-n distribution, the pulse mean φ-q distribution, and skewness of the φ-q distribution. We used the needle-plain electrodes with tip radius 30μm and 300μm at sine wave applied voltage of 1.25 kVp and 2 kVp. We found that the frequency dependences of these partial discharge characteristics are small. © 2017 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:504 / 509
页数:5
相关论文
共 10 条
[1]  
Illias H.A., Et al., Partial Discharge Phenomena within an Artificial Void in Cable Insulation Geometry: Experimental Validation and Simulation, IEEE Trans. DEI, 23, 1, pp. 451-459, (2016)
[2]  
Lei Z., Et al., Partial Discharges of Cavities in Ethylene Propylene Rubber Insulation, IEEE Trans. DEI, 21, 4, pp. 1647-1659, (2014)
[3]  
Florkowska B., Et al., Interaction of Conductor with Polymeric Materials (XLPE/EPR) at Partial Discharges, IEEE Trans. DEI, 19, 6, pp. 2119-2127, (2012)
[4]  
Sekii Y., Degradation of Low-density Polyethylene and Cross-linked Polyethylene by Partial Discharge, IEEE Trans. DEI, 17, 1, pp. 116-124, (2010)
[5]  
Ueta G., Et al., Insulation Characteristics of Epoxy Insulator with Internal Crack-shaped Micro-defects, IEEE Trans. DEI, 21, 3, pp. 1216-1225, (2014)
[6]  
Song J., Slot Discharge Pattern of 10 kV Induction Motor Stator Coils under Condition of Insulation Degradation, IEEE Trans. DEI, 20, 6, pp. 2091-2098, (2013)
[7]  
Ueta G., Et al., Insulation Characteristics of Epoxy Insulator with Internal Crack-shaped Micro-defects, IEEE Trans. DEI, 20, 4, pp. 1444-1452, (2013)
[8]  
Levesque M., Effect of Surface Degradation on Slot Partial Discharge Activity, IEEE Trans. DEI, 17, 5, pp. 1428-1440, (2010)
[9]  
Hasegawa T., Kimura K., Shibuya Y., Influence of Applied Voltage Frequency on the Swarming Pulsive Microdischarges in Closed Voids, T. IEE Japan, 112 A, 7, pp. 658-664, (1992)
[10]  
Kuraishi T., Okamoto T., Takahashi T., Miyazaki S., Suzuki H., Dependence of Partial Discharge Characteristics on Applied Voltage Frequency with IEC(b) Electrode System, IEEJ Trans. FM, 131, 10, pp. 866-871, (2011)