Heat and mass transfer performance of porous corrugated packing in heat-source tower

被引:2
作者
Lü Z. [1 ]
Liang C. [1 ]
Huang S. [1 ]
Zhang X. [1 ]
机构
[1] School of Energy and Environment, Southeast University, Nanjing
来源
Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology) | 2018年 / 49卷 / 04期
关键词
Heat transfer; Heat-source tower; Mass transfer; Porous corrugated packing;
D O I
10.11817/j.issn.1672-7207.2018.04.031
中图分类号
学科分类号
摘要
A plastics porous corrugated plate packing was proposed which had large specific surface area and was punched with holes on its surface. Cross-flow heat-source tower experiment system was established. The influence of air mass flow flux, liquid desiccant mass flow flux on the heat and mass transfer performance of porous corrugated packing was studied and compared with that of herringbone corrugated packing under the same conditions. The results show that the mesh structure of the porous corrugated packing promotes liquid film's crossflow on the both sides of the packing and perturbation of liquid film surface. When the air mass flow flux is 2.5 kg/(m2•s), the heat transfer coefficient of porous corrugated packing is 9.5% larger than that of herringbone corrugated packing and porous corrugated packing's heat transfer is 2 times larger than that of herringbone corrugated packing, which gives reference to enhance the heat and mass transfer and to reduce the volume of heat-source tower. © 2018, Central South University Press. All right reserved.
引用
收藏
页码:1003 / 1010
页数:7
相关论文
共 17 条
[1]  
Li N., Zhang W., Wang L., Et al., Experimental study on energy efficiency of heat-source tower heat pump units in winter condition: Measuring Technology and Mechatronics Automation (ICMTMA), 2011 Third International Conference on, IEEE, pp. 135-138, (2011)
[2]  
Wen X., Liang C., Zhang X., Experimental study on heat transfer coefficient between air and liquid in the cross-flow heat-source tower, Building and Environment, 57, pp. 205-213, (2012)
[3]  
Chen Q., Wang Y., Xu Y., A thermal resistance-based method for the optimal design of central variable water/air volume chiller systems, Applied Energy, 139, pp. 119-130, (2015)
[4]  
Cheung H., Braun J.E., Empirical modeling of the impacts of faults on water-cooled chiller power consumption for use in building simulation programs, Applied Thermal Engineering, 99, pp. 756-764, (2016)
[5]  
Lo C., Tsai S., Lin B., Economic dispatch of chiller plant by improved ripple bee swarm optimization algorithm for saving energy, Applied Thermal Engineering, 100, pp. 1140-1148, (2016)
[6]  
Jang J.Y., Bae H.H., Lee S.J., Et al., Continuous heating of an air-source heat pump during defrosting and improvement of energy efficiency, Applied Energy, 110, pp. 9-16, (2013)
[7]  
Jiang Y., Dong J., Qu M., Et al., A novel defrosting control method based on the degree of refrigerant superheat for air source heat pumps, International Journal of Refrigeration, 36, 8, pp. 2278-2288, (2013)
[8]  
Wang F., Liang C., Wu C., Et al., Frosting and defrosting characteristics of hydrophobic fin surfaces, Journal of Central South University (Science and Technology), 47, 4, pp. 1368-1373, (2016)
[9]  
Lee C.K., Effects of multiple ground layers on thermal response test analysis and ground-source heat pump simulation, Applied Energy, 88, 12, pp. 4405-4410, (2011)
[10]  
Rezaei B.A., Kolahdouz E.M., Dargush G.F., Et al., Ground source heat pump pipe performance with Tire Derived Aggregate, International Journal of Heat and Mass Transfer, 55, 11-12, pp. 2844-2853, (2012)