摘要
Aim at the problems of small output flow rate and large return flow of the tapered flow pipe valve-less piezoelectric pump, combined with the blocking effect of the tapered flow pipe and overflow dam step structure, a tapered stepped flow pipe valveless piezoelectric pump is developed. The flow resistance characteristics of the tapered stepped flow pipe are analyzed theoretically. The finite element software is used to compare the flow field simulation of the tapered stepped flow pipe valveless piezoelectric pump and the tapered stepless valveless piezoelectric pump, and an experimental prototype of the tapered stepped flow pipe valveless piezoelectric pump is made to measure the flow of two pumps at different frequencies and driving voltages. The experimental results show that when the peak to peak value of driving voltage is 180 V and the driving frequency is 18 Hz, the maximum flow rate of the tapered stepless flow pipe valveless piezoelectric pump reaches 6.20 ml/min, and the output flow of the tapered stepless valveless piezoelectric pump reaches the maximum 8.04 ml/min, which is increased by 29% compared with the tapered stepless flow pipe valveless piezoelectric pump. The results show that the tapered stepped-tube valveless piezoelectric pump can effectively inhibit the backflow phenomenon in the tapered flow pipe, and has a better output flow than the stepless piezo pump, which verifies the feasibility of the tapered stepless valveless piezoelectric pump. © 2024 Nanjing University of Aeronautics an Astronautics. All rights reserved.
引用
收藏
页码:602 / 607and626
相关论文
共 23 条
[1]  
LI H Y, LIU J K, LI K, Et al., A review of recent studies on piezoelectric pumps and their applications[J], Mechanical Systems and Signal Processing, 151, (2021)
[2]  
CHEN S, QIAN C P, CHENG W T, Et al., A low frequency driven piezoelectric pump with flexible valve[J], Sensors and Actuators A:Physical, 319, (2021)
[3]  
WANG Ying, ZHANG Jianhui, YAN Qiufeng, Study on piezoelectric pump with symmetrical and spiral shaped valve[J], Journal of Vibration, Measurement & Diagnosis, 37, 5, pp. 1025-1032, (2017)
[4]  
WANG J T, LIU Y, SHEN Y H, Et al., A resonant piezoelectric diaphragm pump transferring gas with compact structure[J], Micromachines, 7, 12, (2016)
[5]  
LIU G J, WANG M, LI P F, Et al., A micromixer driven by two valveless piezoelectric pumps with multistage mixing characteristics[J], Sensors and Actuators A:Physical, 333, (2022)
[6]  
HUANG J, ZOU L, LI Z J, Et al., Development and performance comparison of valveless piezoelectric pumps with asymmetrical channels[J], Sensors and Actuators A:Physical, 314, (2020)
[7]  
FU Jun, ZHANG Jianhui, WANG Ying, Et al., Research on semi-flexible valve piezoelectric pump[J], Journal of Vibration, Measurement & Diagnosis, 39, 5, pp. 1005-1010, (2019)
[8]  
TIAN Xiaochao, YANG Zhigang, WU Yue, Et al., Simulation analysis and experiment of valve-less gas piezoelectric pump[J], Journal of Vibration, Measurement & Diagnosis, 38, 4, pp. 785-791, (2018)
[9]  
ZHANG Jianhui, CAO Bingxin, CHEN Daogen, Et al., Experimental verification on valve-less piezoelectric pump with hemisphere-segment bluff-body[J], Optics and Precision Engineering, 22, 1, pp. 76-84, (2014)
[10]  
XIA Qixiao, ZHANG Jianhui, LEI Hong, Et al., Theoretical analysis of novel valveless piezoelectric pump with cluster of unsymmetrical hump structure[J], Optics and Precision Engineering, 16, 12, pp. 2391-2397, (2008)