Conductor rail overhead contact line on the folding bridge in Anklam

被引:0
|
作者
Schatkowski, Kay [1 ]
Furrer, Rico [2 ]
Wili, Urs [1 ]
机构
[1] DB Netze, Produktionsdurchführung Neustrelitz I.NP-O-D Nsz, Adolf-Friedrich-Str. 21, Neustrelitz,17235, Germany
[2] Furrer+Frey AG, Thunstr. 35, Bern 6,3000, Switzerland
来源
eb - Elektrische Bahnen | 2015年 / 113卷 / 6-7期
关键词
Overhead lines;
D O I
暂无
中图分类号
TM75 [线路及杆塔];
学科分类号
摘要
The construction of an overhead contact line on movable bridges forms a speciality within the network of DB Netz AG, since, due to the differing designs of the bridges, contact line designs adjusted to each individual application are required. For equipping the folding bridge over the navigable river Peene near Anklam DB Netz AG's experience and the know-how of the suppliers, gained in world-wide applications, was combined and an overhead contact line consisting of a conductor rail for a speed of 120km/h was installed.
引用
收藏
页码:342 / 346
相关论文
共 50 条
  • [31] Wind action on overhead contact line equipment
    Schmidt, Peter
    Schulz, Helge
    Berthold, Gunter
    Kiessling, Friedrich
    eb - Elektrische Bahnen, 2001, 99 (09): : 378 - 385
  • [32] Reducing the diversity of overhead contact line components
    Wili, Urs
    Furrer, Rico
    eb - Elektrische Bahnen, 2011, 109 (4-5): : 216 - 219
  • [33] Development and testing of a tuned mass damper for overhead contact rail systems
    Calleja-Duro, Victoria
    Fernandez-Diaz, Ramn-Angel
    Barreiro-Garcia, Joaquin
    Calvo-Calvo, Alvaro
    DYNA, 2017, 92 (06): : 680 - 687
  • [34] Influence of the conductor temperature error on the overhead line ampacity monitoring systems
    Albizu, I.
    Fernandez, E.
    Mazon, A. J.
    Bengoechea, J.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2011, 5 (04) : 440 - 447
  • [35] Parametric resonance mechanism of conductor galloping without icing on overhead line
    Liu L.
    Hao Z.
    Cui Y.
    Xing Y.-F.
    Cai W.
    Deng C.
    Cui, Yun (kyalex@sina.com), 2018, Nanjing University of Aeronautics an Astronautics (31): : 308 - 313
  • [36] Elucidation of Damage to Overhead Contact Line System Caused by Bridge Oscillation Generated by Passing Trains and its Countermeasures
    列車通過時の高架橋振動に伴う電車線路設備損傷の現象解明と低減対策
    Tsunemoto, Mizuki (tsunemoto.mizuki.26@rtri.or.jp), 2025, 145 (01) : 9 - 19
  • [37] Calculation of the overhead transmission line conductor temperature in real operating conditions
    Ľubomír Beňa
    Vladimír Gáll
    Martin Kanálik
    Michal Kolcun
    Anastázia Margitová
    Alexander Mészáros
    Jakub Urbanský
    Electrical Engineering, 2021, 103 : 769 - 780
  • [38] Strength Analysis of Medium Voltage Overhead Line Crossarms for Updating Conductor
    Kiitam, Ivar
    Taklaja, Paul
    Pohlak, Meelis
    Podra, Priit
    Palu, Ivo
    2019 ELECTRIC POWER QUALITY AND SUPPLY RELIABILITY CONFERENCE (PQ) & 2019 SYMPOSIUM ON ELECTRICAL ENGINEERING AND MECHATRONICS (SEEM), 2019,
  • [39] Overhead line thermal rating calculation based on conductor replica method
    Lawry, DC
    Daconti, JR
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 880 - 885
  • [40] Application of overhead rigid conductor line to mountain tunnel of conventional lines
    Oya, Akinori
    Shimizu, Masatoshi
    Mandai, Tuyoshi
    Nishi, Kentaro
    Tago, Masaaki
    2005 IEEE International Conference on Industrial Technology - (ICIT), Vols 1 and 2, 2005, : 234 - 238