Conductor rail overhead contact line on the folding bridge in Anklam

被引:0
|
作者
Schatkowski, Kay [1 ]
Furrer, Rico [2 ]
Wili, Urs [1 ]
机构
[1] DB Netze, Produktionsdurchführung Neustrelitz I.NP-O-D Nsz, Adolf-Friedrich-Str. 21, Neustrelitz,17235, Germany
[2] Furrer+Frey AG, Thunstr. 35, Bern 6,3000, Switzerland
来源
eb - Elektrische Bahnen | 2015年 / 113卷 / 6-7期
关键词
Overhead lines;
D O I
暂无
中图分类号
TM75 [线路及杆塔];
学科分类号
摘要
The construction of an overhead contact line on movable bridges forms a speciality within the network of DB Netz AG, since, due to the differing designs of the bridges, contact line designs adjusted to each individual application are required. For equipping the folding bridge over the navigable river Peene near Anklam DB Netz AG's experience and the know-how of the suppliers, gained in world-wide applications, was combined and an overhead contact line consisting of a conductor rail for a speed of 120km/h was installed.
引用
收藏
页码:342 / 346
相关论文
共 50 条
  • [21] Influence of Key Parameters on High Speed Overhead Conductor Rail and Pantograph System
    Chen, Long
    Liu, Zhigang
    Zhang, Jing
    Hu, Zeyao
    ADVANCES IN DYNAMICS OF VEHICLES ON ROADS AND TRACKS, IAVSD 2019, 2020, : 201 - 211
  • [22] Interoperability assessment of the overhead conductor rail systems of ÖBB-Infrastruktur AG
    Sturzeis, Wolfgang
    Dreßler, Thomas
    eb - Elektrische Bahnen, 2022, 120 (11): : 450 - 455
  • [23] Impact of a non-elastic conductor elongation on the overhead power line conductor sags
    Vpliv neelastičnega raztezka vodnikov na povese pri Daljnovodih
    1600, Electrotechnical Society of Slovenia (83): : 1 - 2
  • [24] Impact of a non-elastic conductor elongation on the overhead power line conductor sags
    Dezelak, Klemen
    Jakl, Franc
    Marusa, Robert
    Pihler, Joze
    Stumberger, Gorazd
    ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2016, 83 (1-2): : 31 - 36
  • [25] A structural health monitoring system of the overhead transmission line conductor
    Zhao, Long
    Zhang, Tian
    Huang, Xinbo
    Zhang, Ye
    Liu, Wei
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2022, 16 (01) : 28 - 39
  • [26] Critical diameter of particles produced in overhead line conductor clashing
    Majstrovic, M.
    Sutlovic, E.
    Ramijak, I.
    APPLIED THERMAL ENGINEERING, 2017, 114 : 713 - 718
  • [27] A Wildfire Model for the Estimation of the Temperature Rise of an Overhead Line Conductor
    Koufakis, Emmanuel Ioannis
    Tsarabaris, Panagiotis Theodoros
    Katsanis, John Stylianos
    Karagiannopoulos, Constantinos G.
    Bourkas, Perikles Damianos
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) : 1077 - 1082
  • [28] Simulation model for the study of overhead rail current collector systems dynamics, focused on the design of a new conductor rail
    Vera, C.
    Suarez, B.
    Paulin, J.
    Rodriguez, P.
    VEHICLE SYSTEM DYNAMICS, 2006, 44 (08) : 595 - 614
  • [29] Online temperature monitoring of overhead contact line at the new German high-speed rail line Cologne-Rhine/Main
    Theune, N
    Bosselmann, T
    Kaiser, J
    Willsch, M
    Hertsch, H
    Puschmann, R
    COMPUTERS IN RAILWAY SIX, 2004, 15 : 875 - 882
  • [30] Software to implement overhead contact line projects
    Winter, Hubert
    eb - Elektrische Bahnen, 2007, 105 (08): : 448 - 453